HomeMy WebLinkAboutSHERWOOD FORTS - PDP/FDP - PDP/FDP110009 - SUBMITTAL DOCUMENTS - ROUND 1 - APPLICATION (7)10
POUDER FIRE AUTHORITY: Automatic*rinklers are required and will be coor4fd with Carle. Addresses will be
mounted as required.
LIGHT & POWER: Doug Martine's research is that there will need to be an upgraded transformer installed and a new
electrical line trenched to the current access point on the existing house. There is a conduit under the alley, so no
paving cuts will be necessary. The phone line will be placed in the same trench.
ENGINEERING: Impact and Oversizing fees, TDRF fees will be paid accordingly. No Transportation Impact Study (TIS) is
necessary, per Ward. Additional ROW or easement will be per review. Sheri Langenberger went to the site and assessed
that the alley is improved and does require anything further. The street sidewalk does need to be improved, per Matt
Baker. The existing will be removed and replaced per city standards. Matt also confirmed that the curb and gutter is in
good shape and does not need to be replaced or repaired. Utility plans have been completed and submitted. No utility
work is been done outside the property boundaries.
HISTORIC PRESERVATION: We spoke with Karen McWilliams. This property is not eligible for historic landmark
designation.
PLANNING: We have submitted a PDP, understand we will have an Administrative Public Hearing, and will follow the
small project fee schedule.
,t
anceptual Review Issues Addressed M
Sherwood Forts @ 617 S. Sherwood St.
Owners: David & Alyce McElhoes
16605 Dancing Wolf Way,
Colorado Springs, CO 80908
719-337-8124
Land Use Data: West Side of S. Sherwood, just north of West Laurel Street. There is an existing single-family house and
garage on property. Legal description is Lot 12 or Block 75 of the Block 76, 77, 85, 87 Subdivision Replat.
ZONING: Property is zoned ZCB which allows 2 attached dwelling units in addition to the existing dwelling (subject to
approval).
Total Lot/Floor Area Calculations:
FAR Calculations:
Total Lot: 9500 sqft Rear 50% of Lot: 4750 sgft
Total Floor Area of Existing: 1153 sqft FAR .33% 1568 sqft
Total Floor Area of Garage: 207 sqft %on Rear %: is 31x24=744'x2= 1488 sqft
Total Floor Area of Proposed: 2258 sqft (24442 +146-New Foyer)
TOTAL Buildings: 3618 sqft (FAR: 38.1%)
Property is in TOD zone so there are no parking requirements. However, the following parking is proposed:
Existing parking spot in existing driveway 1 space
Proposed parking off alley 3 spaces
Total Parking Spaces After Development 4 spaces
Proposed parking off alley will be paved, be 5' from the property line, and conform to Section 3.2.2 (L) of the Land Use
Code.
Proposed dwelling unit entrances are not feasible to face the adjacent street due to setback constraints, but they are
accessed by a concrete walkway from the street sidewalk and the alley parking. The lot width is 50 wide; the front
setback, side yards width, and rear yard setbacks meet the minimum requirements. The peak of the two story addition
is 23' tall. The Elevations sheets show an angle line for the height requirement indicating that the building is properly
setback to conform to the height requirement alongside yards. Therefore, the addition conforms to this requirement.
STORMWATER UTILITY: The proposed net increase in impervious area is 2001 sqft (see drainage plan for calculations).
Therefore, only a grading plan is required, which is included in the Utility Plans. Wes Lamarque requested spot
elevations on the utility plans which have been included along with any survey pins found and their elevations.
WATER & WASTEWATER: Mains and manholes are noted on the utility plans. We have fees and water rights costs from
Roger (well, really Mary O) that will be paid at permitting.
ENVIRONMENTAL PLANNING: Tim Buchanan walled the site and identified all of the existing trees on site as Elms. We
will work with him on the 2-3 to be removed for the parking spaces and property access. The existing garage is planned
to be used for bike storage and a trash enclosure.