Department: Zoning
Contact: Gary Lopez, 970-416-2338, glopez(cDfcgov.com
Topic: General
Number: 2 Issue Originated: 06/08/2011
06/08/2011: In creating the additional two (2) four -bedroom dwelling units PLUS any
bedroom numbers greater than three (3) but no more than four (4) which is the max.
number of bedrooms in the existing single family being converted LUC 3.8.16(E)(2) will
apply. This permits the Occupancy Limit of three to increase to four unrelated persons. Units will
only have 3 bedrooms.
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project, please
feel free to contact me at 970-221-6206. Acknowledged
Sincerely,
Emma McArdle
City Planner
11
Fort Collins
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov.com
06/23/2011: There are line over text & text over text issues. Acknowledge
Topic: Site Plan
Number: 1 Issue Originated: 06/23/2011
06/23/2011: There are line over text & text over text issues. Acknowledged
Number: 2 Issue Originated: 06/23/2011
06/23/2011: Please increase the text on sheet 1, it is too small. Acknowledged
Department: Water -Wastewater Engineering
Contact: Roger Buffington, 970-221-6854, rbuffington(a)fcgov.com
Topic: Construction Drawings
Number: 1 Issue Originated: 06/21/2011
06/21/2011: The responses to conceptual review comments indicate that a fire sprinkler
system will be installed; however, no fire line is shown on the utility plans. Separate fire sprinkler
line will not be needed. A tank will be installed to meet the sprinkler system requirements.
Number: 2
Issue Originated: 06/23/2011
06/23/2011: Move the water meter to a meter pit in a landscaped area. Meter pit must be
within 2 feet of the curb stop, and curb stop must be in easement or R.O.W. Acknowledged,
meter pit location marked on the grading plan.
Department: Zoning
Contact: Gary Lopez, 970-416-2338, glopez(a)fcgov.com
Topic: General
Number: 1 Issue Originated: 06/08/2011
06108/2011: By attaching the existing house and proposed "duplex" via foyer/laundry room
this now becomes a tri-plex or multi -family. While this property is located in
Transit -oriented development (TOD) overlay zone and minimum parking standards will not
apply it is suggested that you provide more than the 4 spaces you are proposing. It
appears that an additional two (2) spaces could be added along the alley where you're
proposing three (3) spaces for a total of five (5) spaces along the alley. One additional space
has been added to the rear parking lot, in addition to the one in the front (total of 5 spaces).
It is our desire to not add any more in the rear due to the buffer trees that we would like to keep
on the south edge of the property.
10
FCollins
ort
/0"�
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
rcgov.com
properties in this area. Any occupied garages must be built to standard, addressed and
possibly fire-sprinklered. Acknowledged
Department: Stormwater Engineering
Contact: Wes Lamarque, 970-416-2418, wlamargue(cDfcgov.com
Topic: General
Number: 1 Issue Originated: 06/21/2011
06/21 /2011: The grading plan needs to be more defined along the property lines and show
clearly how the contractor is to grade the site. Acknowledged
Number: 2 Issue Originated: 06/24/2011
06/24/2011: Please label the grading plan as Drainage, Grading, and Erosion Control
Plan. Acknowledged
Department: Technical Services
Contact: Jeff County, 970-221-6588, icountv(&fcgov.com
Topic: Construction Drawings
Number: 4 Issue Originated: 06/23/2011
06/23/2011: Please change the sheet 2 description on sheet 1. Sheet 2 is not a
subdivision plat. Acknowledged
Number: 5 Issue Originated: 06/23/2011
06/23/2011: There are line over text & text over text issues. Acknowledged
Number: 6 Issue Originated: 06/23/2011
06/23/2011. Please increase the text on sheet 2, it is too small. Acknowledged
Department: Technical Services
Contact: Jeff County, 970-221-6588, icounty(cDfcgov.com
Topic: Construction Drawings
Number: 7 Issue Originated: 06/23/2011
06/23/2011: There is cut off text on sheet 3. Acknowledged
Number: 8 Issue Originated: 06/23/2011
06/23/2011: The details on sheet 5 are poor quality. Please increase the resolution or
change to a line drawing. Acknowledged
Topic: Landscape Plans
Number: 3
N
Issue Originated: 06/2312011
Fort Collins
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov.com
(townhomes) not more than three stories above grade plane in height with a separate
means of egress. Acknowledged
Also, PFA will not sign off on this project until any and all references to this being a
"duplex" are removed. This is inaccurate and confusing, and I do not wish to perpetuate
this throughout the process. Acknowledged
2006 International Fire Code 903.2.7
Number: 2 Issue Originated: 06/15/2011
06/15/2011: WATER SUPPLY
Fire hydrants, where required, must be the type approved by the water district having
jurisdiction and the Fire Department. Hydrant spacing and water flow must meet
minimum requirements based on type of occupancy. Minimum flow and spacing
requirements include:
• Commercial and multi -family dwellings 1,500 gpm at 20 psi residual pressure, spaced
not further than 300 feet to the building, on 600-foot centers thereafter
These requirements may be modified if buildings are equipped with automatic fire
sprinkler systems.
NOTE: No existing hydrants were shown on plans. Fire Hydrant location is shown on the
neighborhood plan page and is within the requirements.
2006 International Fire Code 508.1 and Appendix B
Department: PFA
Contact: Carle Dann, 970-219-5337, CDANN(a)poudre-fire.org
Topic: General
Number: 3 Issue Originated: 06/15/2011
06/15/2011: ADDRESS NUMERALS
Address numerals shall be visible from the street fronting the property, and posted with a
minimum six-inch high numerals on a contrasting background. (Bronze numerals on
brown brick are not acceptable). If the numerals are mounted on a side of the building
other than the side off of which it is addressed, the street name is required to be posted
along with the numerals.
NOTE: Because the back units are set back from the street, PFA will require not only
address numerals and unit addressing, but also a monument -type sign on the east (front)
side of the structure, showing that there are three units. This is similar to what PFA
required for other, existing, multi -family dwellings. Acknowledged, monument location shown
on the grading plan (see legend).
2006 International Fire Code 505.1
Number: 4
Issue Originated: 06/15/2011
06/15/2011: GARAGE: The garage is not allowed to be used as a sleeping/Residential
occupancy, per Fire and Building Code requirements. This has been an issue with several
Fort Collins
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins. CO 80522
970.221.6750
970.224.6134 - fax
fcgov.com
track to comply with all the adopted City Codes and Standards listed below. The proposed
project should be in the early to mid -design stage for this meeting to be effective and is
typically scheduled after the Conceptual Review meeting. Applicants of new commercial
or multi -family projects are advised to call 416-2341 to schedule a pre -submittal meeting.
Applicants should be prepared to present site plans, floor plans, and elevations and be
able to discuss code issues of occupancy, square footage and type of construction being
proposed. Will schedule a pre -submittal meeting shortly.
Number: 8
Issue Originated: 06/21/2011
06/21/2011: Construction design (building permit) shall comply with the standards in the
letter from Russ Hovland provided in the redline materials. Acknowledged
Department: Light And Power
Contact: Doug Martine, 970-224-6152, dmartine(cbjcoov.com
Topic: General
Number: 1
Issue Originated: 06/10/2011
06110/2011: The electric service to the existing house will need to be relocated before
commencement of construction of the duplex. Also, as mentioned in the applicant's
notes, installation of a new pad type electric transformer near the N.W. corner of the lot will
be necessary. One or more of the existing trees in this area may need to be removed by
the owner. All costs for this construction, plus electric development charges will apply.
Due to the existing trees, the owner may be required to provide at least a portion of the
electric utility trench. Contact Light & Power Engineering at (970)221-6700 with any
questions. Will meet with Doug Martine to look at the existing line and how to move it prior
to construction commencement
Number: 2 Issue Originated: 06/10/2011
06/10/2011: When finalized, please send an AutoCad drawing of the site plan to Terry Cox
at TCOX(a)FCGOV.COM. Acknowledged
Department: PFA
Contact: Carie Dann, 970-219-5337, CDANN(d)Doudre-fire.orp
Topic: General
Number: 1 Issue Originated: 06/15/2011
06/15/2011: CLARIFICATION OF TERMINOLOGY: In the past during discussions with the
applicant, they have referred to this project as a "duplex." Two units are being added to an
existing single-family structure, making this a TRlplex, not a duplex. As a triplex, this
becomes an R occupancy under both the International Fire Code and International Building
Code. An automatic sprinkler system installed in occupancies in accordance with Section
903.3 shall be provided throughout all buildings with a Group R (Residential) fire area.
Exceptions: Detached one- and two-family dwellings and multiple single-family dwellings
Fort Collins
Number: 8
Community Development and
Neighborhood services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov.com
Issue Originated: 06/22/2011
06/22/2011: Is the existing driveway proposed to change in anyway? Currently the
minimum width for a residential driveway is 12', however if the existing drive is going to
stay, the existing width of 9' is sufficient. Driveway will be paved and the curb and gutter
widened to 12', and drive to front lot line will be 12' wide, to meet this requirement
Number: 9
Issue Originated: 06/22/2011
06/22/2011: Just a note that the driveway approach will need to be paved in Portland
cement from the street to the back of ROW. Please add a note on the utility plan
specifying this. Acknowledged
Number: 10
Issue Originated: 06/22/2011
06/22/2011: Due to the extent of improvements, no Development Construction Permit will
be needed. Also, unless other departments will need some of their standard language
included in a Development Agreement, one will not be required by Engineering. Acknowledged
Department: Internal Services
Contact: Russ Hovland, ,
Topic: General
Number: 1
Issue Originated: 06/21/2011
06/21/2011: This is a 3-unit multi -family building, not a duplex. A 3-plex (R-2 occupancy)
is regulated under the 2009 IBC not the IRC. The applicant is not to refer to this as a
duplex in any way, shape or form. Acknowledged
Number: 2 Issue Originated: 06/21/2011
06/21/2011: Fire Sprinkler system is required at building permit review. Acknowledged
Number: 3 Issue Originated: 0612112011
06/21/2011: 1-hour dwelling unit separation is required at building permit review. Acknowledged
Number: 4 Issue Originated: 06/21/2011
06/21/2011: Radon reduction system is required at building permit review. Acknowledged
Number: 5
Issue Originated: 06/21/2011
06/21/2011: Egress openings (windows) for sleeping rooms are required at building
permit review. Acknowledged
Number: 6
Issue Originated: 06/21/2011
06/21/2011: Any wall closer than 10' to a property line must be a 1-hour fire rated wall with
limited openings (door and windows) allowed. Acknowledged
Number: 7
Issue Originated: 06/21/2011
06/21/2011: Building Permit Pre -submittal meetings are required: This meeting is offered
to assist the designer/builder by assuring, early on in the design, that the new project is on
U
Fort Collins
Community Development and
Neighborhood services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6760
970.224.6134 - fax
fcgov. com
Department: Engineering Development Review
Contact: Andrew Carney, 970-221-6501, acarney(a)fcgov.com
Topic: General
Number: 1 Issue Originated: 06/22/2011
06/22/2011: The vicinity map may not be dark enough to scan. Also, please include a
boundary around the map. Lastly, a scale should be included. If not to scale, simply label it
as N.T.S.. Acknowledged
Number: 2 Issue Originated: 06/22/2011
06/22/2011: The hand written date will not scan, please have it printed like the rest of the
text. No longer applicable
Department: Engineering Development Review
Contact: Andrew Carney, 970-221-6501, acarney(a)fcgov.com
Topic: General
Number: 3
Issue Originated: 06/22/2011
06/22/2011: The abbreviated general notes you provided should be sufficient, however
please renumber them (1,2,3...). Also please include the name of the specific drainage
report for the project along with the firm that completed the study. Lastly, the note
regarding variances is not needed as none have been requested or approved for this
project, please remove. Per Wes in conceptual review "no drainage plan is needed in old town
area if under 5000 sgft impervious is being added." Acknowledged on other comments.
Number: 4
Issue Originated: 06/22/2011
06/22/2011: There are numerous scanning and line over text issues on the utility and
grading sheets. There is quite a bit of information shown that does not belong in the utility
sheets. Before the plans can be signed, they will need to be cleaned up and clearly legible.
Please carefully review redlines for complete comments. Acknowledged
Number: 5 Issue Originated: 06/22/2011
06/22/2011: Sheet #2 is not a plat as it is labeled in the sheet index; also it is not needed
in the utility set. Acknowledged
Number: 6
Issue Originated: 06/22/2011
06/22/2011: Spot elevations are needed for all lot comers, and finish floors/top of
foundation of buildings. Also, spot elevations are not needed throughout the site, unless it
is specifically needed to call out a specific important point such as in a drainage feature.
Acknowledged
Number: 7 Issue Originated: 06/22/2011
06/22/2011: Please show the eastern side of Sherwood street (C&G, sidewalk, and
ROW). Acknowledged
Fort of
Number: 6
Community Development and
Neighborhood services
281 North College Avenue
PO Box 580
Fort Collins. CO 80522
970.221.6750
970.224b134 - fax
fcgov com
Issue Originated: 06/21/2011
06/21/2011: The first paragraph references the Land Use Code, but references the
incorrect section. This is proposing structural additions and exterior alterations, the
planning objectives suggest it is not in that first paragraph. Please revise for the next
submittal. This project is being reviewed under Section 4.9(B)(2)(a)3, not 4.9(B)(1)(a)3.
Acknowledged
Department: Current Planning
Contact: Emma McArdle, 970-221-6206, emcard le(a)fcgov.Corn
Topic: Planning Objectives
Number: 7
Issue Originated: 06/21/2011
06/21/2011: The planning objectives state this is proposed as 2 - 4 bedroom units in
addition to the existing home. Four bedroom rentals must comply with Sections 3.8.28,
which limits NCB properties to have one tenant per 350 s.f. of habitable space. This limits
each unit to 3 bedrooms. If you add square footage to get the 4 bedrooms per unit, you
will also need to comply with Section 3.816(E) Increasing the Occupancy Limit - this
requires mutli-family dwellings to provide "additional open space, recreational areas,
parking areas and public facilities as are necessary to adequately serve the occupants of
the development and to protect the adjacent neighborhood." Acknowledged as 3 bedroom
units only.
Topic: Site Plan
Number: 8 Issue Originated: 06/21/2011
06/21/2011 : Please add/fix the following on the site plan:
- "Rear Half' to Floor Area Ratio Line label. The Rear FAR calculation should be shown
with the Total Lot/Floor Area Calculations.
/ - Please label square footages of the existing structures on the plan. Call out the square
V !ootages of each structure in the Original Structure square footages (1157 + 207).
Take off landscaping on the proposed site plan, or put all on and get rid of landscape
plan.
V,- Percentages for property coverage is missing 4.4%.
- Fix the arrows on the 4' new sidewalk, it points at the curb and gutter and the area
between the lot and sidewalk.
- Either have gray lined existing and bolder lined proposed to differentiate what is existing
vs what is proposed to change, or label.
--L=This is Lot 12 Block 76 of what? Original Town Plat? Write the entire legal.
v- Up the size of the signature block, this will be hard to read in the future.
v- Add location of lighting for parking.
✓- Is there fencing? Please show if so.
Acknowledged
Fort of
Ycordingly2.1(J) Irrigation - an irrigation plan meeting these standards will be
to be reviewed by Water Conservation (FYI). Acknowledged
Department: Current Planning
Contact: Emma McArdle, 970-221-6206, emcardle(o7fcgov.com
Topic: General
Number: 4
Community Development and
Neighborhood services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970. 224,6134 - fax
fcgov com
required at building permit
Issue Originated: 06/21/2011
06/21/2011: Applicable Section 3.2.2 Access Circulation and Parking standards
- 3.2.2(C)(4)(a) and (b) At least one bicycle parking space shall be provided, this is
accommodated in the garage.
- 3.2.2(D)(c) Pavement, all off street parking shall be surfaced with asphalt, concrete or
other material in conformance with City standards, project in compliance with this
standard.
3.2.2(D)(3)(d) Parking Lot Lighting - shall be down directional and provide security for
residents. Please show where lighting will be. Completed
3.2.2(K) Required number of parking spaces (not applicable for TOD, but as reference I
sited what would be required) 2.5 per 4 bedroom unit, 2 per 3 bedroom unit - would have
been required to provide 7 if not in TOD based on current proposal.
Number: 5 Issue Originated: 06/21/2011
06/21/2011: How will trash service be handled? Please add a note on the plan indicating
or designate a location on the site plan for a trash enclosure. You may want to contact
V one of the trash companies in town to see what is common for tri-plexes. Separate Trash
Fnclosure to be built outside the garage
Topic: Landscape Plans
Number: 10 Issue Originated: 06/21/2011
06/21/2011: Please fix/add the following on the landscape plan:
- Say what is happening to the trees in the parking area on the existing plan, then don't
show them there on the proposed landscape plan. (removed, relocated, to where, etc)
Temporary drainage silt fence and hay/straw barrier is not necessary on plans. Maybe
on building permit plans, but not these.
- I would prefer to see existing trees be of a lighter line weight and proposed to be darker
so I can tell what is proposed vs existing.
- There is a oval shaped something, 12' callout and a tree to the west of the garage, this is
not on the site plan, what is this? Add to the site plan if this is a patio or something.
- You have called out "no irrigation" on the lot, this may not be allowed. Typically at building
permit, irrigation plans are submitted for review. I have contacted Water Conservation to
see if this does not apply in all cases. I'll get you an answer as soon as I hear from them.
Acknowledged
Topic: Planning Objectives
City of
Fort Collins
Department: Current Planning
Contact: Emma McArdle, 970-221-6206, emcardle(a)fcoov.com
Topic: General
Number: 2
Community Development and
Neighborhood services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 • fax
fcgov.com
Issue Originated: 06/21/2011
06/21/2011: Article 4 District Standards:
- Use subject to a Type 1 (administrative) review and public hearing according to Section
4.9(13)(2)(a)(3).
- 4.9(D)(1) Density - Minimum lot size is equivalent to the total floor area but not less than
5,000 square feet. Total Floor area is 3618, therefore minimum lot size is 5,000 s.f.;
proposal is in compliance.
- 4.9(D)(5) Rear FAR - The maximum rear FAR is .33, the proposed is .31, in compliance
with standards.
- 4.9(D)(6) Dimensional Standards
- Minimum lot width is 50', site is in compliance,
- Minimum setbacks - 15' front, 5' rear, side 5' (if structure is over 18' then additional
setback is required of 1' for each 2' above 18') - project is in compliance with these
standards.
- Max height is 3 stories, the proposed is 2 in compliance with this standard.
-4.9(E)(1) Building Design
- Exterior walls are parallel to the lot lines,
- The primary entrance is located on the front wall of the building (existing entrance),
-Second floor does not overhang 1 st,
Need to know the pitch to verify it is in compliance (minimum pitch of 2:12, max
12:12). Pitch Shown
4.9(E)(2) Bulk and Massing
- Max height is 3 stories, proposed is 2 in compliance with these standards,
4.9(E)(4) Landscape/hardscape material
- max of 40% of front yard shall be inorganic material - Please label ground cover to
verify if in compliance. Front Yard is Moderate MoistureTurf, and is marked accordingly.
- 4.9(E)(5) Site Design - If the parking space in the front is intended to be permanent
parking then it needs to extend beyond the front setback of the structure according to this
standard. Rear of parking space off street does not extend past building front setback.
Number: 3
Issue Originated: 06/21/2011
06/21/2011: Applicable Section 3.2.1 Landscape and Tree Protection Standards
- 3.2.1(D) - full tree stocking is provided (existing), and street trees exist meeting
standards (unless Tim Buchanan, City Forester, has comments about health).
- 3.2.1(E)(2) Landscape area treatment, all areas without building or paving shall be
landscaped, plan is in compliance.
- 3.2.1(E)(5) Parking lot interior landscaping - the yard would qualify for this standard, will
the trees in the parking area be moved or removed? Trees to be removed and marked
City of
art Collins
Community Development and
Neighborhood services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
rcgov.com
June 27, 2011
David McElhoes
16605 Dancing Wolf Way
Colorado Springs, CO 80908
City staff and outside reviewing agencies have reviewed your submittal for Sherwood Forts - 617 S.
Sherwood St., and we offer the following comments:
Department: Current Planning
Contact: Emma McArdle, 970-221-6206, emcardle(a)fcgov.com
Topic: Building Elevations
Number: 9 Issue Originated: 06/21/2011
Please revise the Elevations sheets as follows:
- label pitch,
- the line for proposed vs. old is confusing,
- add east, west, north, south to the elevation titles,
- what is the color of the existing structure, how is the denim blue compatible?
Pitch has been labeled, an existing line placed between old and new structures,
and elevation names have been changed. Stucco color is a blue to match the
existing structure.
Topic: General
Number: 1
Issue Originated: 06/21/2011
06/21/2011 Prior to submittal the applicant thought that they had approval from building
and fire to refer to this as a duplex, planning staff stated that this was not the case for
planning documentation, but if others were ok using this terminology for other purposes
planning staff could not say how others would review the project. In staff discussion since
submittal, that is not the case. For all purposes, this project shall be referred to as a
tri-plex not duplex addition on rear of lot, which would not be a premitted use in this zone
district. Please revise all documents to reflect this.
Acknowledged
City of Planning, Dew opment & Transportation
Fort Collins Community De
of Neighborhood Services
281 North College Avenue
P.O.P.Box 580
Fort Collins, CO 80522.0580
Phone: (970) 221-6760
Letter of Transmittal
To: 1 A�+- �� Date:
c
L Project:
From:
TRA,NSMITTED HEREWITH ARE: Redlined Utility Plans / f 1Lo,-,° r!SCC
See attached sheet for number of copies to resubrdit
❑ Redlined Storm Drainage Report
G
b n
❑ Development Agreement
Please sign, seal, date, and return all copies of this agreement.
Changes in the agreement take two (2) days to process if they are acceptable to the City. Please
take this into account in your schedule. Again, all copies must be returned.
❑ Original Mylars Needing Revisions
Please return with the "post -if' notes intact.
❑ Original Mylars with City Signatures
Please return one (1) mylar and signed and stamped blueline print copies for our files.
❑ Development Construction Permit Application
Please fill out and return to the front counter with application fee and all required attachments.
❑ Development Construction Permit for your Signatures
Please sign (but do not date) and return.
❑ Attached is your Copy of the Development Construction Permit
❑ Draft Development Agreement
For your review and comments. Please Call with your comments or questions. Let me know if
everything is okay.
❑ Attached is your Copy of the Development Agreement
Other: