HomeMy WebLinkAboutCOLORADO IRON & METAL - FDP - FDP110005 - CORRESPONDENCE - REVISIONS (3)Oty of
F6rt Collins
Be sure and return all of your redlined plans when you re -submit.
Community Development and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins. CO 80522
970.221.6750 970.224.6134 - fax fcgov. com
If you have any questions regarding these issues or any other issues related to this project, please
feel free to contact me at 970-221-6206.
Sincerely,
Emma McArdle
City Planner
Staff Review Letter Generated: 6/28/2011 at 1:52 pm
City of
Fort Coltins
Department: Technical Services
Community Development and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins. CO 80522
970.221.6750 970.224.6134 - fax rcgovcom
Contact: Jeff County, 970-221-6588, icountyOfcoov.com
Topic: Plat
Number: 12
06/24/2011: No comments.
Topic: Site Plan
Number: 4
06/24/2011: No comments.
05/17/2011: No comments.
Department: Traffic Operation
Contact: Ward Stanford, 970-221-6820, wstanford(rDfc4ov.com
Topic: Construction Drawings
Issue Originated: 06/24/2011
Issue Originated: 05/17/2011
Number: 4 Issue Originated: 05/26/2011
05/26/2011: Sheet C10: Please cleanup the signing and striping plans so the curbs, and
new lane lines stand out from the existing info. Please minimize the grey scale of the
station line and markings.
Topic: Landscape Plans
Number: 1 Issue Originated: 05/26/2011
05/26/2011: Please move Relocated Tree # 11 further west. It is within the sight triangle of
the east access drive.
Number: 2 Issue Originated: 05/26/2011
05/26/2011: Please verify that the Patmore Ash shown just west of the middle access
drive is not within the sight triangle for the west access.
Number: 3 Issue Originated: 05/26/2011
05/26/2011: Please move the Hackberry shown just east of the west access out of the
sight triangle area.
Department: Water -Wastewater Engineering
Contact: Roger Buffington, 970-221-6854, rbuffington(Efcgov.com
Topic: Construction Drawings
Number: 4 Issue Originated: 06/21/2011
06/21/2011: The existing fire hydrant near the west drive is an older style hydrant with the
6" valve attached to the hydrant. In order to move this hyrant back, it will be necessary to
temporarily shutdown the 12" main in Buckingham. This could have an effect on water
quality in the area; therefore, it is VERY important for the contractor to coordinate this work
with Water Utilities. Add a note on the plans to coordinate the relocation of the hydrant
with Water Utilities (See note on redlined plans).
Number: 5
06/21/2011: See redlined plans for other comments and revisions.
Issue Originated: 06/21/2011
7
Staff Review Letter Generated: 6/28/2011 at 1:52 pm
City of
Fort Collins
`f
Department: Stormwater Engineering
Community Development and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6760 970.224.6134 - fax fcgov.com
Contact: Wes Lamarque, 970-416-2418, wlamargueanfcgov.com
Topic: General
Number: 7 Issue Originated: 05/19/2011
06/24/2011: Reminder
05/19/2011: Please add a note on the site plan that the detention pond can not be used for
metal stockpiling.
Number: 10 Issue Originated: 06/24/2011
06/24/2011: Please revise water quality calcs and table on the detail sheet per redlines.
Department: Technical Services
Contact: Jeff County, 970-221-6588, icounty(rDfcgov.com
Topic: Building Elevations
Number: 6
06/24/2011: No comments.
05117/2011: No comments.
Topic: Construction Drawings
Issue Originated: 05/17/2011
Number: 7 Issue Originated: 05/17/2011
06/2412011: The north arrow is still incorrect. Please change the direction or remove it
from the sheet.
05/17/2011: Please correct the north arrow on sheet C9.
Number: 13 Issue Originated: 06/24/2011
06/24/2011: There is one line over text issue on sheet C11.
Number: 14 Issue Originated: 06/24/2011
06/24/2011: There are two buildings labeled as Proposed Building 2 on sheet C11.
Topic: Easements
Number: 15
06/24/2011: No comments.
Topic: Landscape Plans
Number: 5
06/24/2011: No comments.
05/17/2011: No comments.
Topic: Plat
Number: 1
05/17/2011: The boundary and legal close.
Issue Originated: 06/24/2011
Issue Originated: 05/17/2011
Issue Originated: 05/17/2011
Number: 2 Issue Originated: 05/17/2011
05/17/2011: The reception number for the 1 V of Buckingham Street ROW will need to be
added prior to mylars.
6
Staff Review Letter Generated: 6/28/2011 at 1:52 pm
Community Deveiopment and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins. CO 80522
970.221.6750 970.224.6134 - fax fcgovcom
Department: PFA
Contact: Carie Dann, 970-219-5337, CDANN(ftoudre-fire.org
Topic: General
Number: 6 Issue Originated: 05/18/2011
05/18/2011: OCCUPANCY REQUIREMENTS:
All existing and proposed structures shall meet requirements for type of occupancy.
Number: 7 Issue Originated: 06/20/2011
06/20/2011: Please label the new (proposed) fire hydrant as such.
Number: 8 Issue Originated: 06/20/2011
06/20/2011: Please ensure follow-up in completing required documents to dedicate the
Emergency Access Easement.
Department: Stormwater Engineering
Contact: Wes Lamarque, 970-416-2418, wlamargue(a)fcnov.com
Topic: Floodplain
Number: 9
06/21/2011:
1) Please resolve per redlines
Issue Originated: 06/21/2011
2) Comment carries: Please add note to Platt indicating project is within Poudre River
500-year floodplain. See redlines for suggestion.
3) New comment: Existing note on plat indicates "Property falls in Zone X of map panel
08069C0983F". Please correct note to reflect project is in SHADED Zone X and panel
number 08069C0979G. See redlines.
4) Contact Floodplain Administrator, Marsha Hilmes-Robinson at 224-6036,
mhilmesrobinson@fcgov.com with any questions. -
Topic: General
Number: 1 Issue Originated: 05/17/2011
06/21/2011: Reminder
05/17/2011: The final signed off -site drainage easement is required before signing of
mylars
Number: 2 Issue Originated: 05/17/2011
06/21/2011: Reminder
05/17/2011: Written approval is required from Larimer County for the outfall draining into
the Lincoln Channel before signing of mylars.
Number: 3 Issue Originated: 05/17/2011
06/2412011: Please add short paragraph in text of the report describing how overflow spill
will flow into existing detention pond to the east.
05/17/2011: An analysis of the emergency spill is needed up to Lincoln Avenue. The City
requires that the spill get to a right-of-way without inundating any structures.
5
Staff Review Letter Generated: 6/28/2011 at 1:52 pm
aty of
Fort Collins
Department: PFA
Community Development and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins. CO 80522
970.221.6750 970.224.6134 - fax fcgov. com
Contact: Carie Dann, 970-219-5337, CDANN(Myoudre-fire.org
Topic: General
Number: 2 Issue Originated: 05/18/2011
05/18/2011: REQUIRED ACCESS
Fire access roads (fire lanes) shall be provided for every facility, building or portion of a
building hereafter constructed or moved into or within the PFA's jurisdiction when any
portion of the facility or any portion of an exterior wall of the first story of the building is
located more than 150 feet from fire apparatus access as measured by an approved route
around the exterior of the building or facility. This fire lane shall be visible by painting and
signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for
approval prior to installation. In addition to the design criteria already contained in relevant
standards and policies, any new fire lane must meet the following general requirements:
Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable
of supporting fire apparatus weights. Compacted road base shall be used only for
temporary fire lanes or at construction sites.
4 Have appropriate maintenance agreements that are legally binding and enforceable.
4 Be designated on the plat as an Emergency Access Easement.
4 Maintain the required minimum width of 20 feet throughout the length of the fire lane
(26 feet on at least one long side of the building when the structure is three or more stories
in height).
If the building is equipped throughout with an approved automatic fire -sprinkler system, the
fire code official is authorized to increase the dimension of 150 feet.
KNOX PADLOCKS: The two proposed gates, if locked, must be equipped with a Knox
Padlock. PFA sells these padlocks for cost in the Fire Prevention Bureau.
ALSO, the proposed EAE is acceptable. Approved signage (NO PARKING - FIRE LANE)
must be installed prior to CO.
2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D
Number: 3 Issue Originated: 05/18/2011
05/18/2011: FIRE SPRINKLERS
No fire line is shown on the utility plan.
Number: 4 Issue Originated: 05/18/2011
05/18/2011: ADDRESS NUMERALS
Address numerals shall be visible from the street fronting the property, and posted with a
minimum six-inch high numerals on a contrasting background. (Bronze numerals on
brown brick are not acceptable). If the numerals are mounted on a side of the building
other than the side off of which it is addressed, the street name is required to be posted
along with the numerals.
At such time buildings 2 and 3 are approved and constructed, we can discuss addressing
of these buildings.
2006 International Fire Code 505.1
►R11t1#77MIP
05/18/2011: FDC CLEARANCE:
Issue Originated: 05/18/2011
The fire sprinkler connection must be clear of all vegetation (other than ground cover) and
any other obstruction, within 36 inches. Please note this clearance for the planting areas.
Staff Review Letter Generated: 6/28/2011 at 1:52 pm
City of
Fort Collins
Department: Light And Power
Contact: Rob Irish, 970-224-6167, rirish(&fc4ov.com
Topic: General
Number: 1
Community Development and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750 970.224.6134 - fax fcgov.com
Issue Originated: 05/17/2011
06/17/2011:
05/17/2011: Owner is responsible for additional square footage charges that were not
previously paid by the Vanworks Sub 2nd Filing.
Number: 2
Issue Originated: 05/17/2011
06/17/2011:
05/17/2011: Contact Light & Power with any change in power requirements. Owner will
need to submit a C-1 form and a One -line diagram to Light & Power for any additional
increase in power requirements. Electric Capacity Fees and Building Site charges will
apply for any increase in power.
Number: 3
Issue Originated: 05/17/2011
06/17/2011:
05/17/2011: Any relocation or modification to existing electric facilities will be at the
owners expense.
Department: PFA
Contact: Carie Dann, 970-219-5337, CDANN(Maoudre-fire.orci
Topic: General
Number: 1
Issue Originated: 05/18/2011
05/18/2011: WATER SUPPLY
Fire hydrants, where required, must be the type approved by the water district having
jurisdiction and the Fire Department. Hydrant spacing and water flow must meet
minimum requirements based on type of occupancy. Minimum flow and spacing
requirements include:
6 Commercial and multi -family dwellings 1,500 gpm at 20 psi residual pressure, spaced
not further than 300 feet to the building, on 600-foot centers thereafter
Residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced
not further than 400 feet to the building, on 800-foot centers thereafter
4 Residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced
not further than 400 feet to the building, on 800-foot centers thereafter.
These requirements may be modified if buildings are equipped with automatic fire sprinkler
systems.
PLEASE NOTE: No existing hydrants are shown on the plans. The existing hydrant near
the entrance to the site meets the distance requirements for the existing structure and the
phase 2 proposed building. However, we need to meet to discuss and resolve
water -supply issues for the phase 3 structure.
2006 International Fire Code 508.1 and Appendix B
3
Staff Review Letter Generated: 6/28/2011 at 1:52 pm
aty of
F6rt Collins
Department: Engineering Development Review
Community Development and Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750 970.224.6134 - fax fcgov.com
Contact: Andrew Carney, 970-221-6501, acarney(cDfcgov.com
Topic: General
Number: 4 Issue Originated: 05/17/2011
06/21 /2011: The easements are being reviewed by the technical services department, I
will update if any corrections need to be made. To finalize the dedication, the dedication
fee ($250) will need to be paid, a deed of dediction will need to be completed (please
contact me for the blank deed) and a check will need to be provided for recording the
document at Larimer County.
05/18/2011: To finalize the off -site drainage easement and the Emergency Access
Easement, a legal description and an exhibit showing the easement will need to be
submitted and reviewed. Also, a Deed of dedication will need to be completed and
submitted along with the TDRF easement dedication fee and the applicable recording fees
to record the final document with Larimer County.
[4/6/10] Letter of intent received. Final easement will be needed prior to approval of plans.
Processing and filling fees will be due for the processing and filing of off -site easements.
[10/12/09] An off -site easement for the storm pipe is needed with this design. A letter of
intent from the off -site property owner(s) is needed prior to being able to schedule this
project for hearing.
Number: 10
Issue Originated: 05/23/2011
06/21/2011: Comment carried forward as a reminder.
05/23/2011: To finalize the project, both a Development Agreement (DA) and a
Development Construction Permit (DCP) will be needed. To begin both please contact
Andrew Carney (221-6501, acarney@fcgov.com) to obtain applications for both
documents, as well as, more information regarding both processes.
Number: 11 Issue Originated: 05/23/2011
06/22/2011: As far as I know, there is no plat being completed with this project. So the
EAE will need to be dedicated via seperate document similar to the other easements.
Please submit the legal and exhibit for review.
05/23/2011: To finalize the emergency access easement, a legal description and an
exhibit showing the easement will need to be submitted and reviewed. Also, a Deed of
dedication will need to be completed and submitted along with the TDRF easement
dedication fee and the applicable recording fees to record the final document with Larimer
County.
Department: Environmental Planning
Contact: Lindsay Ex, 970-224-6143, lex(a)fcgov.com
Topic: General
Number: 1
05/10/2011: No comments.
Department: Light And Power
Contact: Rob Irish, 970-224-6167, rirish(a)fcgov.com
2
Issue Originated: 05/10/2011
Staff Review Letter Generated: 6/28/2011 at 1:52 pm
Fort Coltins
June 28, 2011
Troy Jones
MTA Planning & Architecture
171 N. College Avenue
Fort Collins, CO 80524
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970, 224.6134 - fax
fcgov.com
City staff and outside reviewing agencies have reviewed your submittal for Colorado Iron & Metal,
and we offer the following comments:
Department: Current Planning
Contact: Emma McArdle, 970-221-6206, emcardle(&fcgov.com
Topic: General
Number: 25
Issue Originated: 06/28/2011
06/28/2011: We will need to add flags in Accela when building permits are filed for phase
3 and 5.
Department: Engineering Development Review
Contact: Andrew Carney, 970-221-6501, acamev(d-)fcgov.com
Topic: General
Number: 3
Issue Originated: 05/17/2011
06/21/2011: The easements are being reviewed by the technical services department, I
will update if any corrections need to be made. To finalize the dedication, the dedication
fee ($250) will need to be paid, a deed of dediction will need to be completed (please
contact me for the blank deed) and a check will need to be provided for recording the
document at Larimer County.
05/18/2011: To finalize the off -site grading/slope easement, a legal description and an
exhibit showing the easement will need to be submitted and reviewed. Also, a Deed of
dedication will need to be completed and submittedalong with the TDRF easement
dedication fee and the applicable recording fees to record the final document with Larimer
County.
[4/6/10]Letter of intent received. Final easement will be needed prior to approval of plans.
Processing and filling fees will be due for the processing and filing of off -site easements.
[10/12/09] Need to show how the grading at the SW corner of the site will tie back into
existing grades. It appears that off -site grading or construction easements will be needed.
Letters of intent to grant these easements will need to be provided prior to the project
being scheduled for hearing.
[5/12/09] Few grade lines at the property lines do not tie to anything.
Staff Review Letter Generated: 6/28/2011 at 1:52 pm
Cit of Planning, Devinopment & Transportation
FCommunity Development & Neighborhood services
Fort Collins
ma�yy,� 281 North College Avenue
P.O. Box 580
Fort Collins, CO 80522.0580
Phone: (970)221-6760
� Letter of Transmittal
To: Date:
Project: 1*
From: ins 7C 1S
TgA,NSMITTED HEREWITH ARE:
Redlined Utility Plans
See attached sheet for number of copies to resubmit
❑ Redlined Storm Drainage Report
❑ Development Agreement
Please sign, seal, date, and return all copies of this agreement.
Changes in the agreement take two (2) days to process if they are acceptable to the City. Please
take this into account in your schedule. Again, all copies must be returned.
❑ Original Mylars Needing Revisions
Please return with the "post -it" notes intact.
❑ Original Mylars with City Signatures
Please return one (1) mylar and signed and stamped blueline print copies for our files.
❑ Development Construction Permit Application
Please fill out and return to the front counter with application fee and all required attachments.
❑ Development Construction Permit for your Signatures
Please sign (but do not date) and return.
❑ Attached is your Copy of the Development Construction Permit
❑ Draft Development Agreement
For your review and comments. Please Call with your comments or questions. Let me know if
everything is okay.
❑ Attached is your Copy of the Development Agreement
Other. `__
7