Loading...
HomeMy WebLinkAboutVALLEY STEEL ADDITION PDP - TYPE 1 - 34-05 - CORRESPONDENCE - (4)Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: Utility plans Number: 34 Created: 10/ 11 /2005 [12/27/05] Include specifications for the insulation so that contractor knows it's not available a Home Depot or similar home improvement centers [ 10/ 11 /05] Provide insulation fors' all,portions_ of the sanitary sewer with • less than 4 feet of cover. Insulation'must be the' type -specifically' made for underground applications. Submit design of the insulation for review. Include specifications for the insulation on the plans. (I have a contact name for product and design information:) THIS IS A FINAL COMPLIANCE ITEM. nt 1MRT Ti,C!; 4ii_ Topic: Water/WW plans Number: 79 Created: 12/27/2005 [12/27/051 Is gas line moving out into the street? If so, provide 10 feet of separation to sewer and check that sewer is a minimum of 10 feet from the water main. Please contact Clark Mapes of the Advance- Planning Department, at 221- 6225, to see if he has any outstanding concerns _or comments regarding the Landscape Plan for the Valley Steel Addition. Be sure and return all red -lined plans -if ./ .when -you re=submit. . If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at 221-6341. Yours Truly, AM Steve Olt City Planner cc: Dan DeLaughter, Engineering Clark Mapes, Advance Planning Stewart & Associates, Inc.. Randy Wright, Quality Wholesale, Building Products.:: . Current Planning file #34-,05 ✓ Page 4 • • Number: 80 Created: 12/28/2005 [12/28/051 Please provide some spot elevations on the grading and drainage plan in the area around the dumpster and parking. We want to be sure that the ramp wall doesn't impede drainage to the detention pond. Number: 81 Created: 12/28/2005 [ 12/28/051 Light and Power has stated that conduit does not need to be provided on this site for future undergrounding. This will be done by the city in the future. Topic:. Site & Landscape Plan Number: 74 Created: 12/23/2005 [12/23/051 No north arrows shown on Site and Landscape Plans. Number: 76 Created: 12/23/2005 [12/23/051 Details are missing some dimensions. Topic: Technical Services Number: 54 Created: 10/ 12/2005 [12/23/051 [ 10/ 12/05] Technical Services would like to know how the ROW is dedicated along Hickory Street. Department: Stormwater-Water-Wastewater Issue Contact: Basil Hamdan Topic: Erosion Control Number: 82 Created: 12/28/2005 [ 12/28/05] 1. Please do a complete sediment/erosion control submittal with all the required elements, including the correct plan notes, project schedule, PS and EFF calculations, etc. Plan will be reviewed at that time. Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Floodplain Number: 61 Created: 12/23/2005 [12/23/051 No more floodplain comments. Topic: Stormwater Number: 62 Created: 12/23/2005 [12/23/051 Please use the City of Fort Collins standard detail for the water quality outlet structure. This can be sent to you electronically. Number: 63 Created: 12/23/2005 [12/23/05] Please revise detention pond summary table. Basin A and D show release rates when there is no pond. Page 3 c. 1603 Access Ramp Details d. 1607 Access Ramp Scoring e. 2501 (If needed) Sidewalk Widening Detail Number: 51 Created: 10/ 12/2005 [12/23/05] repeat [ 10/ 12/05] Reference current/updated soils investigation report on cover sheet. Number: 52 _. Created: 10/ 12/2005' [12/27/051 It appears that the west access to the site is flat. How will this drain? [ 10/ 12/05] Show curb return.Aetails including spot elevations to verify that minimum grades are met (FC). Number: 64 Created: 12/23/2005 [12/23/051 Signature block should be on every page. Number: 65 Created: 12/23/2005 [12/23/051 We will need to resolve, -the issue ofthe gas/electric/sewer locations. Minimum separation, between gas and sewer is 10' (some flexibility on this if it is absolutely iirip'ossible)..: _ .. Number: 66 Created: 12/23/2005 [12/23/051 Please show the p6werto ibe undergrounded with the proposed location of the new line. Number: 67 Created: 12/23/2005 [12/23/051 Number: 68 Created: 12/23/2005 [12/23/05] PRPA line shown asWAPA!on'plat. Number: 69 Created: 12/23/2005 [12/23/05] See redlines for legend revisions. Number: 70 z ....Created: 12/23/2005, [12/23/051 Drive access radii are not labeled- please add these Iabels to the grading plan. Number: 71 Created: 12/23/2005 [ 12/23/051 Label all retaining ;walls, on plans, ; • • • • : • • I Page 2 STAFF PROJECT REVIEW City of Fort Collins JCL Architecture Date: 01 /05/2006 c/o Justin Larson 201 South College Avenue Fort Collins, CO.80524 Staff has reviewed your submittal for VALLEY STEEL ADDITION, FINAL PLANS - TYPE 1, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Dan DeLaughter Topic: Details Number: 72 Created: 12/23/2005 [12/23/051 1. Sheet 6A detail: provide 1' clear flat area behind sidewalk before any grading starts. 2. Section lines not shown on southwest ramp detail. 3. Modify Drawing 1602 to include street trees. 4. Add a plan view of sidewalk showing curbside tree plantings with all appropriate dimensions. This is on the Landscape Plan but must be in the construction set as well. 5. You can remove detail # 2501 since all sidewalks will be new (not widened). Topic: General Number: 21 Created: 9/8/2005 [ 12/27/05] Power line easement on the north part of the site not shown on construction plans. [9/8/05] Show all easements needed for the development on both plat and plans. Detention areas need to be included in drainage easements. Number: 39 Created: 10/ 12/2005 [ 12/ 19/05] [ 10/ 12/05] Label and dimension the right-of-way (ROW) along Hickory Street for the portion to the east of your property. We need to be sure that the ROW has actually been dedicated before the sewer can be built. Number: 50 Created: 10/ 12/2005 [12/27/051 1602 should be modified to include tree grates. You can also remove the sidewalk widening detail since all sidewalk will be new. [ 10/ 12/051 Please provide the following standard details: a. 1601 Standard Sidewalk b. 1602 Sidewalk Detail- modified to show tree grates Page 1