HomeMy WebLinkAboutTOLMAR SUBDIVISION (BLDG EXPAND.) - PDP - 38-07 - CORRESPONDENCE - (17)expansion to the north in Phase 3. Revise the utility plans with the existing alignment and a proposed method of re-routing. [12/26/07] Provide a blow-up of the area where the proposed re-route of the fire line and domestic water service is shown. It appears that the re- routes (particularly the fire line) are much too close to the proposed building addition on the north side of the building. Number: 47 Created: 3/25/2008 904�, [3/25/08] Revise note, etc. where fire hydrant is being re -located as shown on the redlined plans. Show existing location of the hydrant. Include the fire hydrant standard detail. At the meeting on March 26th between City staff and the applicant it was determined that staff will be ready to accept mylars of the subdivision plat (3 sets) and utility plans (1 set + 1 set of prints) after the issues stated in this comment letter are sufficiently addressed. Specifically, comments from Engineering, Stormwater, and Water/Wastewater need to be addressed. Please be sure and return all red -lined plans when you submit mylars. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at 221-6341. Yours Truly, Steve Olt, City's Project Planner cc: Susan Joy W.P. Carey and Co. LLC Planning & Zoning file #38-07A Page 4 Department: Stormwater-Water-Wastewater Issue Contact: Basil Hamdan Topic: Drainage Plan Number: 50 Created: 3/26/2008 VO RC [3/26/081 It seems that Basin 14 in the ultimate construction phase would be bypassing the pond. Please address in report how this was handled in the original report. Please fill out the erosion control schedule. Topic: Drainage report Number: 48 Created: 3/25/2008 PORC [3/25/08] Please provide a reference for the original drainage report for the Atrix Labs site in the addendum. Explain how water quality is being addressed with the proposed addition. Does the pond have a water quality outlet structure and was it designed to handle this addition? Please add a discussion in the addendum. Please provide an erosion control cost estimate for each phase of construction. Topic: Utility Plans Number: 49 Created: 3 / 25 / 2008 [3/25/08] Please add maintenance notes to the pipe profile sheets stating Y�lie that the owner shall be responsible for maintaining the storm sewers on this site. A note should also be added stating that all storm sewer construction shall be inspected by the City. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: Water/Wastewater Number: 25 Created: 12 / 26/ 2007 [3/25/081 The re-route shown on the plans to too close to the UG electric. If moved south to provide separation, the re-route is too close to the building excavation, and the integrity of the thrust block at the 45-degree bend is jeopardized. Has consideration been given to starting the re-route in the street north of the curb and gutter? [ 1 / 22 / 08] The alignment of the fire line has been checked in the field and extends onto the site perpendicular to the water main in the street. As such, re-routing of the fire line will likely be needed prior to the building Page 3 Topic: Site/Landscape Plans Number: 38 Created: 1 / 18/ 2008 [3/24/081 The Site/Landscape plans received with this submittal are not showing any phasing this time? As long as they show phasing as shown in the Minor Amendment submittal, we're good to go. [1/ 18/08] Beautiful job coordinating the phasing with the utility plans. Thank you very much! The only comment I will have in Final Compliance is that a few scanning issues need to be addressed and that's pretty much it. I highlighted the line over text problem areas so you can block out the background in those places. The colored phasing lines are great(!) but unfortunately they're not allowed, per Appendix E6. You may substitute the 3 lines of color with just one black and white line separating the phases. The labeling you have shown addressing the overlapped phasing is perfect! Thanks again. Topic: Utility - Detail Sheets pe Number: 16 Created: 12 / 24 / 2007 [3 / 24 / 08] Thank you for adding the details. I hate to be "picky" but the entire 1602 detail has to be on the sheet, not just a portion of it. I'm sorry. [ 1 / 18 / 08] Final Compliance: Please provide 701 and 1602. [12/24/07] Please add 701, 1601, 1602, 1603, 1606a, 1607. Topic: Utility - General Number: 40 Created: 1 / 18 / 2008 [3/24/081 Only two minor places that need "tweaking" before going to (%Ong mylars. I tabbed the sheets with a post -it note and highlighted them in pink so you can easily find them. [1/ 18/08] I've highlighted in pink a few scanning issues that will need to be addressed in Final Compliance prior to going to mylars. Great job with the plans! Department: Light & Power Issue Contact: Doug Martine Topic: Electric Utility Number:31 Created: 12/26/2007 [2/29/08] [ 12 / 26/ 07] Electric development charges will apply for the previously undeveloped portion of this site. These charges will apply even if no additional power is required, and will be payable as a condition of continued electric service to the site. Please contact Doug Martine at Light & Power Engineering (224-6152). Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 46 Created: 3 / 25 / 2008 [3/25/08] PFA has no additional comments or concerns. Page 2 palj6 9d w e STAFF PROJECT REVIEW JR Engineering, LLC c/o Timothy J. Halopoff, P.E. 2620 East Prospect Road, Suite 190 Fort Collins, CO 80525 Date: 3/28/2008 Staff has reviewed your submittal for TOLMAR SUBDIVISION (BUILDING EXPANSION - 701 CENTRE AVE.) - FINAL PLANS, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Steve Olt Topic: General Number: 43 Created: 3/24/2008 [3/24/081 Megan Harrity of the Larimer County Assessor's office indicated that the signature block on the subdivision plat is stating a different owner [W.P. Carey & Co., Inc.] than what the County's records currently show [TFARMA(CO)QRS 16-93, INC]. Number: 44 Created: 3/24/2008 [3/24/08] The condition of Project Development Plan approval has been satisfied with the addition of the word "Existing" in front of the New Mercer Ditch Easement label (located near the southeast corner of the site) on the Final subdivision plat. Department: Engineering Issue Contact: Susan Joy Topic: Plat Number: 45 Created: 3 / 25 / 2008 [3/25/08] From Technical Services: 1. Boundary closes. 2. Lot 1 has no sight distance easement so the restriction statement on Sheet 1 is not needed. Page 1