Loading...
HomeMy WebLinkAboutKECHTER TOWNHOMES - PDP200010 - - UTILITY PLANSKECHTER RDFOSSIL CREEK RESERVOIRPROJECTLOCATIONI-25 // US 87 E HARMONY RDSTRAUSS CABIN RDZIEGLER RD ROCK CREEK DR16'7'PARKTRAVEL7'PARK7'(MIN.)PKWY30' ROADWAY53' ROW(MIN)WALK4.5'6'.5 Min. Fence SetbackUTIL.ESMT.9'9'UTIL.ESMT.(MIN.)PKWY7'WALK(MIN)4.5'CS1COVER STEET1 JULY 2020CONTACT INFORMATIONPROJECT TEAM:VICINITY MAPNORTHKECHTER TOWNHOMESPROJECT TEAM:Ripley Design, IncRussell Lee419 Canyon Avenue, Suite 200Fort Collins, Colorado 80521(970) 224.5828TWGRyan Kelly, Acquisitions Director1301 East Washington Street, Ste 100Indianapolis, IN 46202(317)559-7009Northern Engineering Services, Inc.Andy Reese301 North Howes Street, Suite 100Fort Collins, Colorado 80521(970) 221-4158PLANNER/LANDSCAPE ARCHITECTOWNER/APPLICANTSITE ENGINEERSHEET INDEXA TRACT OF LAND LOCATED IN THE SOUTHEAST QUARTER OF SECTION 4, TOWNSHIP 6 NORTH, RANGE 68 WEST OF THE 6TH P.M.CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADONorthern Engineering Services, Inc.Bob Tessely, PLS301 North Howes Street, Suite 100Fort Collins, Colorado 80521(970) 221-4158SITE SURVEYORTYPICAL SECTIONS1CS1COVER SHEET2CS2GENERAL & CONSTRUCTION NOTES3 - 4EX1 - EX2EXISTING CONDITIONS & DEMOLITION PLAN5 - 6PV1 - PV2PAVING PLANUTILITY SHEETS7OU1OVERALL UTILITY PLAN8 - 9U1 - U2UTILITY PLANGRADING SHEETS10OG1OVERALL GRADING PLAN11 - 12G1 - G2GRADING PLANROADWAY SHEETS13R1STREET D & STREET A PLAN & PROFILE14R2STREET B & STREET C PLAN & PROFILE15R3QUASAR WAY PLAN & PROFILE16R4KECHTER ROAD RE-STRIPING PLANDETAIL SHEETS17 - 18D1 - D2SITE DETAILS19 - 20D3 - D4UTILITY DETAILS21D5DRAINAGE DETAILSDRAINAGE SHEETS22EC1OVERALL EROSION CONTROL PLAN23 - 24EC2 - EC3EROSION CONTROL PLAN25EC4EROSION CONTROL DETAILS26DR1DRAINAGE EXHIBITUTILITY PLANS FORUTILITY CONTACT LIST: *UTILITY COMPANY* This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility forthe accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility forlocating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center ofColorado (UNCC) at 811 for additional information.PHONE NUMBERGAS-----------------Xcel Energy-----------------------------Pat Kreager(970) 225-7840ELECTRIC--------City of Fort Collins Light & Power--Rob Irish(970) 224-6167CABLE-------------Comcast----------------------------------Don Kapperman(970) 567-0425TELECOM.--------CenturyLink-------------------------------William Johnson(970) 377-6401WATER------------Fort Collins Loveland Water----------Chris Pletcher(970) 226-3104WASTEWATER--South Fort Collins Sanitation --------Chris Pletcher(970) 226-3104STORMWATER-City of Fort Collins Utilities-----------Wes Lamarque(970) 416-2418CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRSheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICT■ land planning ■ landscape architecture ■■ urban design ■ entitlement ■Design StudioAldo Sebben1350 Pine Street, Suite 6Boulder, Colorado 80302(303) 250.9525ARCHITECTI hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with allapplicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fullyresponsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans.These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibilityby the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctnessof the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantitiesrequired. The review shall not be construed for any reason as acceptance of financial responsibility by the City of FortCollins for additional quantities of items shown that may be required during the construction phase.DISCLAIMER STATEMENT:CERTIFICATION STATEMENT:BENCHMARK #1:City of Fort Collins Benchmark 2-03Location: South side Kechter Road approximately 0.6 miles west of Strauss Cabin Road onthe east end of the south parapet wall of the bridge over the Dixon Canyon Lateral.Elevation= 4898.14 (NAVD88)BENCHMARK #2:City of Fort Collins Benchmark 13-13Location: On the west side of Strauss Cabin Road, approximately 90-ft south of KechterRoad, on the northwest corner of a storm inlet.Elevation= 4887.05 (NAVD88)Please note: This plan set is using NAVD88 for a vertical datum. Surroundingdevelopments have used NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) fortheir vertical datums.If NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) is required for any purpose,the following equation should be used: NGVD29 Unadjusted Datum (prior City of FortCollins Datum) = NAVD88 - 3.18'Basis of BearingsSouth line of the Southeast Quarter of Section 4-6-68 as bearing South 88°11'39" East.Original Field SurveyNorthern Engineering Services, INC.Project Number: 1664-003Date: June, 2020ORIGINAL FIELD SURVEY BY:PROJECT BENCHMARKS:(53' FL-FL)RESIDENTIAL LOCAL STREETN.T.S. CS2CONSTRUCTION NOTES GENERAL &2SheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICTA. GENERAL NOTES1.All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards andspecifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations.Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictivestandard shall apply. All work shall be inspected and approved by the City of Fort Collins.2.All references to any published standards shall refer to the latest revision of said standard, unless specifically statedotherwise.3.These public improvement construction plans shall be valid for a period of three years from the date of approval by the Cityof Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process bythe City of Fort Collins prior to commencement of any work shown in these plans.4.The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the Cityof Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approvalof these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all suchresponsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the Cityof Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise fromany errors and omissions contained in these plans.5.All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collinsstandards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer.6.The type, size, location and number of all known underground utilities are approximate when shown on the drawings. Itshall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route ofthe work before commencing new construction. The Developer shall be responsible for unknown underground utilities.7.The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (ContactColorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, andthe Erosion Control Plan.8.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property.Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s).9.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registeredengineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to theStormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units.For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior tothe release of any building permits in excess of those allowed prior to certification per the Development Agreement.10.The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result ofgroundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless suchdamage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater,and/or storm drainage facilities in the development.11.All recommendations of the Preliminary Drainage Report, dated July 22, 2020 by Northern Engineering Services, Inc., shallbe followed and implemented.12.Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion controlmeasures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilizedwith hard surface or landscaping.13.The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public streetsystem. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broomsweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector.14.No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit orDevelopment Construction Permit is obtained, if applicable.15.The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencementof construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City ofFort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earthdisturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not availableafter proper notice of construction activity has been provided, the Developer may commence work in the Engineer'sabsence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing revealsan improper installation.16.The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and allutility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavementdesign report does not correspond with the results of the original geotechnical report, the Developer shall be responsiblefor a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavementthickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensedProfessional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior toplacement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of FortCollins Engineer approves the final report.17.The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgradeand the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector.The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approvedplans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins beforeinstallation of base course or asphalt will be allowed on the streets.18.All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages ofroad construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stagework. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary forbuilding connections.19.Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred tofor additional criteria for roads within these districts.20.All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the constructioncriteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval.21.Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a siteinspection for any tree removal requiring a permit.22.The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring,traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching.23.The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriateRight-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any constructionactivities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic controldevices as may be required by the construction activities.24.Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the Cityof Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor,however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipmentto reinstall the sign as needed.25.The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development relatedto the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing andstriping related to directing traffic access to and from the Development.26.There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort CollinsEngineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by LarimerCounty.27.The Developer is responsible for providing all labor and materials necessary for the completion of the intendedimprovements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically notedotherwise.28.Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown,contact the Designer for clarification, and annotate the dimension on the as-built record drawings.29.The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriatestandards and specifications, and a copy of any permits and extension agreements needed for the job.30.If, during the construction process, conditions are encountered which could indicate a situation that is not identified in theplans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately.31.The Developer shall be responsible for recording as-built information on a set of record drawings kept on the constructionsite, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shallsubmit record drawings to the City of Fort Collins Engineer.32.The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2)for the project as well as the basis of bearings. The information shall be as follows:BENCHMARK #1:City of Fort Collins Benchmark 2-03Location: South side Kechter Road approximately 0.6 miles west of Strauss Cabin Road on the east end of the southparapet wall of the bridge over the Dixon Canyon Lateral.Elevation= 4898.14 (NAVD88)BENCHMARK #2:City of Fort Collins Benchmark 13-13Location: On the west side of Strauss Cabin Road, approximately 90-ft south of Kechter Road, on the northwest cornerof a storm inlet.Elevation= 4887.05 (NAVD88)Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) for their vertical datums.If NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) = NAVD88 - 3.18'Basis of BearingsSouth line of the Southeast Quarter of Section 4-6-68 as bearing South 88°11'39" East.33.All stationing is based on centerline of roadways unless otherwise noted.34.Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks,curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of thisproject, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans,prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy.35.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its originalcondition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before anycuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finishedpatch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine.In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may berequired. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the Cityof Fort Collins Inspector at the time the cuts are made.36.Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that whichexisted before construction, or to the grades and condition as required by these plans.37.Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections.38.After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be freefrom material and workmanship defects for a minimum period of two years from the date of acceptance.39.The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, includingstorm drainage structures and pipes, for the following private streets: N.A.40.Approved Variances are listed as follows:·N/ACONSTRUCTION NOTESA. Grading and Erosion Control Notes1.The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site.2.There shall be no earth-disturbing activity outside the limits designated on the accepted plans.3.All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling,stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in theconstruction sequence as indicated in the approved project schedule, construction plans, and erosion control report.4.At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion includingkeeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsiblefor installing and maintaining all erosion control facilities shown herein.5.Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existingvegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practicalperiod of time.6.All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be keptin a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosioncontrol BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbingactivity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch,landscaping, etc.) is installed, unless otherwise approved by the City/County.7.In order to minimize erosion potential, all temporary (structural) erosion control measures shall:a.Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired orreconstructed as necessary in order to ensure the continued performance of their intended function.b.Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by theerosion control inspector.c.Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector.8.When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removalof all sediment and debris from all drainage infrastructure and other public facilities.9.The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets,sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day.10.All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner andlocation so as not to cause their release into any waters of the United States.11.No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport bysurface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seededand mulched.12.The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned uponcompletion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA).13.City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow thedischarge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited todiscarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. Thedeveloper shall at all times take whatever measures are necessary to assure the proper containment and disposal ofpollutants on the site in accordance with any and all applicable local, state, and federal regulations.14.A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as tocontain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completionof construction activities the concrete washout material will be removed and properly disposed of prior to the area beingrestored.15.Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developershall implement whatever measures are determined necessary, as directed by the City.16.See separate Stormwater Management Plan / Erosion Control Report for Waterfield Third Filing for additional information.17.A vehicle tracking control pad shall be installed when needed for construction equipment, including but not limited topersonal vehicles exiting existing roadways. No earthen materials, i.e. stone, dirt, etc. shall be placed in the curb & gutteror roadway as a ramp to access temporary stockpiles, staging areas, construction materials, concrete washout areas,and/or building sites.B. Street Improvement Notes1.All street construction is subject to the General Notes on the cover sheet of these plans as well as the StreetImprovements Notes listed here.2.A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of FortCollins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at adepth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt.3.Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inchesfrom the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavementto a distance where a clean construction joint can be made.4.Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base materialshall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer.5.Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay.Valve box adjusting rings are not allowed.6.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its originalcondition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting andpatching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blendsmoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of FortCollins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut thenew asphalt overlay work.7.All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (includingColorado supplement) and as per the Right-of-Way Work Permit traffic control plan.8.The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and priorto installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completelyremoved and reconstructed to drain properly.9.Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on thesubgrade material (when a full depth section is proposed) or on the subgrade and base material (when a compositesection is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolledwith a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined bythe City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface.The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall bepreformed in the presence of an Inspector.C. Traffic Signing and Pavement Marking Construction Notes1.All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signingand Marking Construction Notes listed here.2.All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic.3.All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD.4.All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads.5.All lane lines for concrete pavement should be epoxy paint.6.Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depictingalignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer priorto permanent installation of striping and symbols.7.Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards.8.Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction.9.All surfaces shall be thoroughly cleaned prior to installation of striping or markings.10.All sign posts shall utilize break-away assemblies and fasteners per the Standards.11.A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. Alldiscrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin.12.The Developer installing signs shall be responsible for locating and protecting all underground utilities.13.Special care shall be taken in sign location to ensure an unobstructed view of each sign.14.Signage and striping has been determined by information available at the time of review. Prior to initiation of the warrantyperiod,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City ofFort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD orthe CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period fornew construction (except fair wear on traffic markings).15.Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, foradditional detail.D. Storm Drainage Notes1.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property.Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s).2.All recommendations of the Preliminary Drainage Report, dated July 22, 2020 by Northern Engineering Services, Inc., shallbe followed and implemented.3.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registeredengineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to theStormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units.For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior tothe release of any building permits in excess of those allowed prior to certification per the Development Agreement.E. Water and Sewer Notes1.All water and sanitary sewer construction shall be performed according to the Fort Collins-Loveland Water District and theSouth Fort Collins Sanitation District Standards and Specifications.2.Construction of water and sewer facilities require a precon meeting with district operations staff prior to construction.3.Contractor shall notify district inspectors prior to starting work.4.Contractor shall contact the Sanitation District for sewer inspection 48 hours prior to connecting to existing sewer stubs.5.All commercial domestic services require a reduced pressure backflow prevention device.6.All water line shall be a minimum of (5) five feet and a maximum of (6) six feet below final grade.7.All District valves shall be operate by District staff only.8.Pipe pressure and vacuum testing shall be witnessed by District Inspectors. Waterline bacteria tests shall also be taken byDistrict Inspectors.9.Once the system is operational and all tests have passed, contractor shall request substantial completion with a letter tothe district that includes the dollar value of the water and sewer improvements listed separately.10.As-builts shall be submitted in pdf and dwg to the District for Final Approval.11.If groundwater is encountered within depth of sewer construction, manholes must be water-proofed.CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR VAULTELECHYD VAULTELECGASSVAULTELECFESCONTROLIRRCONTROLIRR CONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRLIDHYDCONTROLIRRCONTROLIRRCONTROLIRRXXWWWX X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXEEGGGGGGGGG G GGGGGWWWW W W XSSSSSSSSXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXPARCEL XWILLOW BROOKPARCEL WWILLOW BROOKPARCEL RWILLOW BROOKPOUDRE R-1 SCHOOL DISTRICTPARCEL NO. 8604000904EXISTING SAN MHRIM=4903.86INV IN=4891.42 (N)INV OUT=4891.22 (E)EXISTING 16" ADSFL=4901.13EXISTING CONCRETE PADTO BE REMOVEDEXISTING HYDRANTTO BE RELOCATEDFND NAIL & BRASSTAG, PLS 33193FND NAIL & BRASSTAG, PLS 33193FND NAIL & BRASSTAG, PLS 33193FND #4 REBARW/YPC, PLS 33193FND #4 REBARW/YPC, PLS 33193FND NAIL & BRASSTAG, W.C., ILLEGIBLEEXISTING IRRIGATION DITCHECLIPSE LANE(51' PUBLIC ROW)QUASAR WAY (51' PUBLIC ROW)FULL MOON DRIVEEXISTING ASPHALT TO BE REMOVEDPROPOSED SAWCUTEXISTING STOPFULL MOON DRQUASAR WAYEXISTING BARRICADETO BE REMOVEDPORTION OF EXISTING FENCE TO BE REMOVED(COORDINATE W/ TRAIL/SIDEWALK CONNECTION)EXISTING SIDEWALKTO BE REPLACED AS REQUIREDDRIP LINEDRIP LINEEXISTING TREECOORDINATE RAMP LOCATION WITHFORESTRY DEPARTMENT TO SAVE TREEKEYMAPKECHTER RD (C.R. 36)QUASAR WAY ECLIPSELANEEX1DEMOLITION PLAN EXISTING CONDITIONS &3NORTH( IN FEET )1 inch = ft.Feet02020204060EX1EX2SheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICTMATCH LINE - SEE SHEET EX2EXISTING ELECTRICELEGEND:GTEXISTING STORM SEWEREXISTING TELEPHONEEXISTING GASEXISTING IRRIGATION BOXEXISTING GAS METEREXISTING TELEPHONE PEDESTALEXISTING TREES (TO REMAIN)FIELD SURVEY BY:NOTES:EXISTING SANITARY SEWERSSEXISTING WATERWEXISTING FENCEXEXISTING WATER METEREXISTING FIRE HYDRANTEXISTING ELECTRIC VAULTPROJECT BOUNDARYEXISTING RIGHT-OF-WAYEXISTING MAJOR CONTOUREXISTING MINOR CONTOURVAULTELECCONTROLIRREXISTING TREES (TO BE REMOVED)EXISTING CABLECTVEXISTING FIBER OPTICFO1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES AREAPPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALLUNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEWCONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALLUNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWNUNDERGROUND UTILITIES.2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL,REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THATMAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDESAPPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE.4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTINGSITE SURVEY.EXISTING OVERHEAD UTILITYOHEOriginal Field SurveyNorthern Engineering Services, Inc.Project Number: 1664-003Date: June, 2020CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR SVAULTELECARVH2OARVH2OWF ESDSSDWSOEVAULTELECTTTT TCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTVCTVCTVCTVCTVCTVCTVTTTTTTTTEEEEEEEEEEEEXXXXXXXXXXXXXXXXXXXXXXXXXXXXEEEEEXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXST ST STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTS T S T S TSTSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSCTVCTVCTVCTVCTVCTVCTVCTVCTVXXXXXELECWWWWWWWWWWWWWWWWWWWWWWWW W WPARCEL XWILLOW BROOKCITY OF FORT COLLINSPARCEL NO. 8609128901EXISTING 18" PVCEXISTING 24" PVC EXISTING 402.9 LF 24" PVC @ 0.19%EXISTING18" RCPEXISTING 376.6 LF 18" RCP @ 0.53%EXISTING CONCRETE PADTO BE REMOVEDPOUDRE R-1 SCHOOL DISTRICTPARCEL NO. 8604000904EXISTING SAN MHRIM=4896.98INV IN=4877.84 (W)INV OUT=4877.78 (SE)EXISTING SAN MHRIM=4897.39INV IN=4877.69 (NW)INV IN=4877.79 (E)INV OUT=4877.59 (S)EXISTING 69.0 LF 24" PVC @ 0.13%EXISTING SAN MHRIM=4898.92INV IN=4878.72 (E)INV OUT=4878.57 (W)FL=4899.09FL=4891.67EXISTING INLETGRATE=4902.05INV IN=4898.56 (N)INV OUT=4893.62 (E)EXISTING 10.5 LF 18" RCP @ 5.05%EXISTING STORM MHRIM=4898.51INV IN=4891.06 (NE)INV OUT=4891.00 (W)EXISTING 69.0 LF18" RCP @ 0.88%EXISTING STORM MHRIM=4897.11INV IN=4889.02 (E)INV OUT=4888.97 (S)EXISTING GATETO BE REMOVEDEXISTING GATETO BE REMOVEDEXISTING GATETO BE REMOVEDEXISTING GATETO BE REMOVEDEXISTING GATETO BE REMOVEDEXISTING 1 STORY WOOD SHEDTO BE REMOVEDEXISTING 1 STORY WOOD SHEDTO BE REMOVEDEXISTING CONCRETE PADTO BE REMOVEDEXISTING FENCETO BE REMOVEDEXISTING FENCETO BE REMOVEDEXISTING FENCETO BE REMOVEDEXISTING FENCETO BE REMOVEDEXISTING WOOD GAZEBOTO BE REMOVEDEXISTING AIR RELEASE VALVETO BE REMOVEDEXISTING AIR RELEASE VALVEPROTECTED BY WOOD POSTSTO BE REMOVEDEXISTING OVERHEAD LIGHTTO BE REMOVEDEXISTING OVERHEAD LIGHTTO BE REMOVEDEXISTING GRAVEL DRIVETO BE REMOVEDEXISTING TELEPHONETO BE REMOVEDEXISTING TELEPHONETO BE REMOVEDEXISTINGELECTRICTO BEREMOVEDEXISTING WATER SHUT OFFTO BE REMOVEDREFERENCE MONUMENTFND 2 1/2" ALUM. CAPON #6 REBAR IN MONUMENT BOXREFERENCE MONUMENTFND 2 1/2" ALUM. CAPON #6 REBAR IN MONUMENT BOXREFERENCE MONUMENTFND 2 1/2" ALUM. CAPON #6 REBAR IN MONUMENT BOXEXISTING IRRIGATION DITCHEXISTING 1 STORY METALFRAMED GARAGETO BE REMOVEDEXISTING 2 STORYWOOD HOMEW/CRAWL SPACE15' UTILITY EASEMENTREC. NO. 20190009470EXISTING LIGHTTO BE RELOCATEDSECTION LINEKECHTER ROAD (C.R. 36)(70' PUBLIC ROW)SAWCUT & REMOVE ASPHALT PAVEMENTSAWCUT & REMOVE 4.5' SIDEWALKSAWCUT & REMOVE ASPHALT PAVEMENTSAWCUT & REMOVE 4.5' SIDEWALKEXISTING GRAVEL DRIVETO BE REMOVEDREPLACE CURB ANDGUTTER ON KECHTEREXISTING DRIP LINEEXISTING TREETO BE REMOVEDEX2DEMOLITION PLAN EXISTING CONDITIONS &4NORTH( IN FEET )1 inch = ft.Feet02020204060EX1EX2KEYMAPKECHTER RD (C.R. 36)QUASAR WAY ECLIPSELANESheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICTMATCH LINE - SEE SHEET EX1EXISTING ELECTRICELEGEND:GTEXISTING STORM SEWEREXISTING TELEPHONEEXISTING GASEXISTING IRRIGATION BOXEXISTING GAS METEREXISTING TELEPHONE PEDESTALEXISTING TREES (TO REMAIN)FIELD SURVEY BY:NOTES:EXISTING SANITARY SEWERSSEXISTING WATERWEXISTING FENCEXEXISTING WATER METEREXISTING FIRE HYDRANTEXISTING ELECTRIC VAULTPROJECT BOUNDARYEXISTING RIGHT-OF-WAYEXISTING MAJOR CONTOUREXISTING MINOR CONTOURVAULTELECCONTROLIRREXISTING TREES (TO BE REMOVED)EXISTING CABLECTVEXISTING FIBER OPTICFO1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES AREAPPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALLUNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEWCONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALLUNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWNUNDERGROUND UTILITIES.2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL,REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THATMAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDESAPPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE.4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTINGSITE SURVEY.EXISTING OVERHEAD UTILITYOHEOriginal Field SurveyNorthern Engineering Services, Inc.Project Number: 1664-003Date: June, 2020CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR XXX X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXLOT 6LOT 4LOT 4LOT 2LOT 3LOT 3LOT 6LOT 1LOT 1LOT 2LOT 5LOT 4LOT 1LOT 4LOT 4LOT 2LOT 3TRACT DLOT 1LOT 1LOT 2LOT 3LOT 4LOT 5TRACT ALOT 5LOT 1LOT 2LOT 3LOT 4LOT 5LOT 6LOT 1LOT 5LOT 4LOT 3LOT 2LOT 1LOT 2BLOCK 7BLOCK 1BLOCK 2BLOCK 8BLOCK 11BLOCK 64.5' SIDEWALK4.5' SIDEWALKDRIVE-OVERCURB / GUTTERADA CURB RAMPADA CURBRAMP6' VALLEY PANDRIVE-OVER CURB / GUTTERDRIVE-OVERCURB / GUTTERADA CURB RAMPADA CURB RAMPDRIVE-OVER CURB / GUTTERPROPOSED53' R.O.W.PROPOSED53' R.O.W.PROPOSED53' R.O.W.PROPOSED 61' R.O.W.PROPOSED 61' R.O.W.~ASPHALT PAVEMENT~END CONCRETE SIDEWALKADJACENT GRADE TO BEFLUSH WITH WALKEND CONCRETE SIDEWALKADJACENT GRADE TO BEFLUSH WITH WALK~ASPHALT PAVEMENT~ ~ASPHALT PAVEMENT~PARCEL XWILLOW BROOKPARCEL WWILLOW BROOKPARCEL RWILLOW BROOKPOUDRE R-1 SCHOOL DISTRICTPARCEL NO. 8604000904STREET AECLIPSE LANEQUASAR WAY STREET D STREET B STREET B30' FL-FL30' FL-FL30' FL-FL~ASPHALT PAVEMENT~30' FL-FLFULL MOON DRIVE4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALKSTOP SIGNEND CONCRETE SIDEWALK,ADJACENT GRADE TO BE FLUSH WITH WALKCOORDINATE RAMP LOCATION W/ FORESTRYTO PROTECT EXISTING TREEPV1PAVING PLAN5CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRNORTH( IN FEET )1 inch = ft.Feet02020204060SheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICTKEYMAPKECHTER RD (C.R. 36)QUASAR WAY ECLIPSELANEPV1PV2EASEMENTSNOTES:1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS ANDPAVEMENT SECTIONS.2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS ANDPROJECT SPECIFICATION MANUAL.3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED INTHE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRSTO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGEDOR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED ORRESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSEPRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THEISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATIONRELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.PROPOSED VERTICAL CURB & GUTTERPROPERTY BOUNDARYEXISTING LOT LINE/ / / / / / / /PROPOSED EDGE OF PAVEMENTASPHALT PAVINGPROPOSED OUTFALL VERTICAL CURB & GUTTERLEGEND:CONCRETE PAVINGMATCH LINE - SEE SHEET PV2 XXXXXXXXXXXXXXXXXXXXTRACT BLOT 4LOT 1LOT 2LOT 5LOT 1LOT 1LOT 4LOT 1LOT 5LOT 2LOT 3LOT 1LOT 6LOT 4LOT 2LOT 3LOT 1LOT 3LOT 2LOT 3LOT 4LOT 5TRACT CLOT 2LOT 3LOT 4LOT 1BLOCK 3BLOCK 4BLOCK 9BLOCK 10BLOCK 5RAINGARDENARAINGARDEN BDRIVE-OVERCURB / GUTTERADA CURB RAMP6' VALLEY PANADA CURB RAMPDRIVE-OVER CURB / GUTTERADA CURB RAMP4.5' SIDEWALK4.5' SIDEWALKDRIVE-OVER CURB / GUTTERCONCRETE DRIVEWAY APRONADA CURBRAMPADA CURBRAMPEND CONCRETE SIDEWALKADJACENT GRADE TO BEFLUSH WITH WALKEND CONCRETE SIDEWALKADJACENT GRADE TO BEFLUSH WITH WALK~ASPHALT PAVEMENT~~ASPHALT PAVEMENT~~ASPHALT PAVEMENT~ ~ASPHALT PAVEMENT~PARCEL XWILLOW BROOKPOUDRE R-1 SCHOOL DISTRICTPARCEL NO. 8604000904CITY OF FORT COLLINSPARCEL NO. 8609128901STREET CSTREET D STREET D STREET BKECHTER ROAD (C.R. 36)(70' PUBLIC ROW)PROPOSED53' R.O.W.30' FL-FL30' FL-FLPROPOSED53' R.O.W.PROPOSED 61' R.O.W.30' FL-FL4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALKDRIVE-OVERCURB / GUTTERCLOSE EXISTINGDRIVEWAYCLOSE EXISTING DRIVEWAY& ADD SIDEWALKSTOP SIGNSTOP SIGN40' NO PARKINGPV2PAVING PLAN6 NORTH( IN FEET )1 inch = ft.Feet02020204060SheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICTKEYMAPKECHTER RD (C.R. 36)QUASAR WAY ECLIPSELANEPV1PV2EASEMENTSNOTES:1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS ANDPAVEMENT SECTIONS.2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS ANDPROJECT SPECIFICATION MANUAL.3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED INTHE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRSTO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGEDOR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED ORRESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSEPRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THEISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATIONRELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.PROPOSED VERTICAL CURB & GUTTERPROPERTY BOUNDARYEXISTING LOT LINE/ / / / / / / /PROPOSED EDGE OF PAVEMENTASPHALT PAVINGPROPOSED OUTFALL VERTICAL CURB & GUTTERLEGEND:CONCRETE PAVINGMATCH LINE - SEE SHEET PV1CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR TTTTGGGGGGGGGGGGGG G G G G G GGGGGGGGGGGGGGEEEEEETTEEEEEEE ETT T EEEEEEEEEEEEEEEEEEEEEEEEEE E EEE EEEEEEEEEEETVAULT ELEC VAULT ELEC GAS S VAULT ELEC FES CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR LID S VAULT ELEC FE S D S S SS HY D CONTROL IRR CONTROL IRR CONTROL IRR D E VAULT ELEC T VAULT ELECCXGCTVTE EW W W W CTV CTV CTV CTV CTV CTV CTV CTV CTVTT E E E E XXXXXXXXXXE EX EG G G GGGGWW STST ST ST ST ST ST ST ST ST STSSSS SS SS SS SS SS SS SS SS SS SS SS SSSS SS SSSSSS CTV CTV CTV CTV X X X X X X X XXXXXXXELEC WWWWWWWWWWWWWWW15' UTILITY EASEMENT REC. NO. 20190009470 PARCEL X WILLOW BROOK PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 FULL MOON DRIVE PROPOSED FIRE HYDRANT CONNECT TO EX SAN MAIN PROPOSED TRANSFORMER PROPOSED TRANSFORMER PROPOSED TRANSFORMER PROPOSED TRANSFORMER APPROXIMATE GAS LOCATION APPROXIMATE GAS LOCATION APPROXIMATE GAS LOCATION APPROXIMATE LOCATION OF CONNECTION TO EX GAS PROPOSED 8" SANITARYPROPOSED 8" WATERPROPOSED 8" SANITARYPROPOSED 8" WATERPROPOSED 8" WATERPROPOSED 8" WATERPROPOSED 8" SANITARYPROPOSED 8" SANITARY PROPOSED 8" WATER PROPOSED 8" SANITARY CITY OF FORT COLLINS PARCEL NO. 8609128901 STREET A (53' PUBLIC ROW) STORM INLET STORM INLET INLET 18" RCP STORM MH 18" RCP STORM MH SAN MH SAN MH 8" PVC 18" PVC SAN MH 24" PVCSAN MH 24" PVC SAN MH24" PVC 18" RCP 18" RCP SAN MH 16" ADS QUASAR WAY(53' PUBLIC ROW)STREET B(53' PUBLIC ROW)STREET C (53' PUBLIC ROW)STREET D(53' PUBLIC ROW)KECHTER ROAD (C.R. 36) (70' PUBLIC ROW) POND OUTFALL STORM DRAIN STORM DRAIN PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED STORM SEWER PROPOSED STORM SEWER PROPOSED STORM SEWER PROPOSED STORM SEWER STORM DRAIN RAIN GARDEN OUTFALL RAIN GARDEN B RAIN GARDEN A RAIN GARDEN OUTFALL PROPOSED TRANSFORMER CONNECT TO EX WATER MAIN CONNECT TO EX STORM MAIN PROPOSED TRANSFORMER STORM DRAIN APPROXIMATE GAS LOCATION APPROXIMATE GAS LOCATION APPROXIMATE LOCATION OF CONNECTION TO EX GAS RELOCATED FIRE HYDRANT PROPOSED TRANSFORMER PROPOSED TRANSFORMERPROPOSED TRANSFORMER PROPOSED TRANSFORMER PROPOSED STORM SEWER POND CURB CHASE SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 25 All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT OU1 OVERALL UTILITY PLAN7 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 KEYMAP KECHTER RD (C.R. 36)QUASARWAYECLIPSE LANE U1 U2 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS - LOVELAND WATER DISTRICT, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 5-FT MINIMUM AND 6-FT MAXIMUM WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV PROPOSED WATER METER PIT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R TTTTGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGEEEEEEEEEEEETE TEEEEEEEEEEEEEE E EEEE E E E EEEEEE E EVAULT ELEC VAULT ELEC GAS S VAULT ELEC FES CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR LID HY DCONTROL IRR CONTROL IRR CONTROL IRRXX W W WXXXXX XXXXXXXXEEG G G G G G G G GGGGGGGW W W WWWSSSSSS SS X X X X X X X X X X X X X X XXXXXXXXXXXXPOUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 W W W S S S S S S S S S S S S S S S S S S SSSSS SSSSSSWW W W W W WWWWWWWWWW W W W W W W W 12" RCP18" RCP 12" PVCPROPOSED TEE W/ 3-WAY VALVING (TYP.) PROPOSED 45° BEND (TYP.) PR SSMH A1-1 CONNECT TO EX WATER MAIN TEE W/ 3-WAY VALVING (TYP.) PR SSMH A1-2 PROPOSED 45° BEND (TYP.) PR SSMH A4 RELOCATED FIRE HYDRANT PR SSMH A3 PR SSMH A3-1 PROPOSED TRANSFORMER PROPOSED TRANSFORMER APPROXIMATE GAS LOCATION APPROXIMATE GAS LOCATION APPROXIMATE LOCATION OF CONNECTION TO EX GAS 4.5' SIDEWALK 4.5' SIDEWALK4.5' SIDEWALKPROPOSED 8" SANITARYPROPOSED 8" WATERPROPOSED 8" SANITARYPROPOSED 8" WATERPROPOSED 8" WATERPROPOSED 8" WATERPROPOSED 8" SANITARY PROPOSED 8" SANITARY 4.5' SIDEWALK 20' UTILITY EASEMENT 6' UTILITY & DRAINAGE EASEMENT 4.5' SIDEWALK 4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 30' FL-FL 53' R.O.W. 30' FL-FL 53' R.O.W.4.5' SIDEWALK9' UTILITY EASEMENT 9' UTILITY EASEMENT 14' DRAINAGE EASEMENT 6' DRAINAGE EASEMENT FES ECLIPSE LANE (53' PUBLIC ROW)QUASAR WAY(53' PUBLIC ROW)SAN MH RIM=4903.86 INV IN=4891.42 (N) INV OUT=4891.22 (E) 16" ADS FL=4901.13 14' DRAINAGE EASEMENT 7' ACCESS EASEMENT 4.5' SIDEWALKSTREET D(53' PUBLIC ROW)STREET A (53' PUBLIC ROW)STREET B(53' PUBLIC ROW)9' UTILITY EASEMENT PROPOSED WATER METER PIT (TYP.) APPROXIMATE LOCATION OF CONNECTION TO EX GAS PROPOSED FIRE HYDRANT PROPOSED TRANSFORMER PROPOSED TRANSFORMER PROPOSED TRANSFORMER 12" PVCW S S S W W PROPOSED TRANSFORMER PROPOSED WATER METER PIT (TYP.) PROPOSED WATER METER PIT (TYP.) PROPOSED WATER METER PIT (TYP.) W W W W W W S 9' UTILITY EASEMENT FES FES FES FES FES 12" RCP IN-LINE DRAIN IN-LINE DRAIN IN-LINE DRAIN IN-LINE DRAIN IN-LINE DRAIN IN-LINE DRAIN IN-LINE DRAIN IN-LINE DRAIN 12" PVC12" PVC12" PVC 12" PVCLOT 6 LOT 4 LOT 4LOT 2 LOT 3 LOT 3 LOT 6 LOT 1 LOT 1 LOT 2 LOT 5 LOT 4 LOT 1LOT 4 LOT 4 LOT 2 LOT 3 TRACT D LOT 1 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 TRACT A LOT 5 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6LOT 1 LOT 5 LOT 4 LOT 3 LOT 2 LOT 1 LOT 2 BLOCK 7 BLOCK 1 BLOCK 2BLOCK 8BLOCK 11BLOCK 6SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 25 All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT U1 UTILITY PLAN8 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 KEYMAP KECHTER RD (C.R. 36)QUASARWAYECLIPSE LANE U1 U2 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS - LOVELAND WATER DISTRICT, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 5-FT MINIMUM AND 6-FT MAXIMUM WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV PROPOSED WATER METER PIT MATCH LINE - SEE SHEET U2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R TTGGGGGGGGGGGG G G G G G G G G G G G GGGGGGGGGGGTEEEETT T EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE E E E EEE E EEEEEEEEEEEEEEEEEEEEEEETS VAULT ELEC W FES D S S D E VAULT ELEC T CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTVTTTTT E E E E E E E EXXXXXXXXXXXX XXXE E E E E STSTST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTST SSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSC T V CTV CTV CTV CTV CTV CTV CTV CTV XXXXXELEC WWWWWWWWWWWWWWWWWWWWWWWWWW15' UTILITY EASEMENT REC. NO. 20190009470 FL=4899.09 FL=4891.67 INLET GRATE=4902.05 INV IN=4898.56 (N) INV OUT=4893.62 (E) 10.5 LF 18" RCP @ 5.05% STORM MH RIM=4898.51 INV IN=4891.06 (NE) INV OUT=4891.00 (W) 69.0 LF 18" RCP @ 0.88% STORM MH RIM=4897.11 INV IN=4889.02 (E) INV OUT=4888.97 (S) 18" PVC SAN MH RIM=4896.98 INV IN=4877.84 (W) INV OUT=4877.78 (SE)24" PVCSAN MH RIM=4897.39 INV IN=4877.69 (NW) INV IN=4877.79 (E) INV OUT=4877.59 (S) 69.0 LF 24" PVC @ 0.13% SAN MH RIM=4898.92 INV IN=4878.72 (E) INV OUT=4878.57 (W) 402.9 LF 24" PVC @ 0.19% 18" RCP 376.6 LF 18" RCP @ 0.53% POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 W W W W W W W W W W W W W W W S S S S S S S S S S S S S S S S S S S S S S S S S S W W W W W W W W W CITY OF FORT COLLINS PARCEL NO. 860912890115" RCP12" PVC15" RCP15" RCP15" RCP FES FES PR SANITARY SEWER CONNECTION (TYP.) PR WATER SERVICE CONNECTION (TYP.) PR FIRE HYDRANT PR TEE W/ 3-WAY VALVING (TYP.) PR SSMH A1 OUTLET STRUCTURE PROPOSED SSMH A (CONNECT TO EX SAN MAIN) PROPOSED STORM MH (CONNECT TO EX STORM MAIN) CURB INLET PR SSMH A2 OUTLET STRUCTURE PR 45° BEND (TYP.) PR TRANSFORMER PROPOSED TRANSFORMER APPROXIMATE GAS LOCATION APPROXIMATE GAS LOCATION APPROXIMATE GAS LOCATION PROPOSED 8" WATER PROPOSED 8" SANITARY4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 30' FL-FL 53' R.O.W. 30' FL-FL 53' R.O.W.4.5' SIDEWALK9' UTILITY EASEMENT 9' UTILITY EASEMENT STREET B(53' PUBLIC ROW)STREET C (53' PUBLIC ROW)STREET D(53' PUBLIC ROW)14' DRAINAGE EASEMENT 7' ACCESS EASEMENT 4.5' SIDEWALK4.5' SIDEWALK4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT POND 1 9' UTILITY EASEMENT 9' UTILITY EASEMENT RAIN GARDEN A KECHTER ROAD (C.R. 36) (70' PUBLIC ROW) CURB INLET 9' UTILITY EASEMENT PROPOSED WATER METER PIT (TYP.) CONNECT TO EX WATER MAIN TEE W/ 3-WAY VALVING (TYP.) RAIN GARDEN B FES PROPOSED TRANSFORMER PROPOSED TRANSFORMER PROPOSED TRANSFORMER 12" PVC12" PVCW W W S 9' UTILITY EASEMENT PROPOSED WATER METER PIT (TYP.) PROPOSED WATER METER PIT (TYP.) OUTLET STRUCTURE FES FES CURB INLET CURB INLET CURB INLETFES IN-LINE DRAIN IN-LINE DRAIN IN-LINE DRAIN IN-LINE DRAIN IN-LINE DRAIN 12" RCP 12" RC P 18" R C P 12" PVC12" PVC12" RCPSIDEWALK DRAIN TRACT B LOT 4 LOT 1 LOT 2 LOT 5 LOT 1 LOT 1 LOT 4 LOT 1 LOT 5 LOT 2 LOT 3 LOT 1 LOT 6 LOT 4 LOT 2 LOT 3 LOT 1 LOT 3 LOT 2 LOT 3 LOT 4 LOT 5 TRACT C LOT 2 LOT 3 LOT 4 LOT 1 BLOCK 3BLOCK 4BLOCK 9BLOCK 10BLOCK 5SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 25 All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT U2 UTILITY PLAN9 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 KEYMAP KECHTER RD (C.R. 36)QUASARWAYECLIPSE LANE U1 U2 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS - LOVELAND WATER DISTRICT, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER SOUTH FORT COLLINS SANITATION DISTRICT SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 5-FT MINIMUM AND 6-FT MAXIMUM WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV PROPOSED WATER METER PIT MATCH LINE - SEE SHEET U1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R VAULTELECVAULTELECGASSVAULTELECFESCONTROLIRRCONTROLIRR CONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRLIDSVAULTELECWFESDSSSSHYDCONTROLIRRCONTROLIRRCONTROLIRRDEVAULTELECTVAULTELECCXGCTV TE EWWWWCTVCTVCTVCTVCTVCTVCTVCTVCTVTTEEEE X XXXXXX XXXEEXEGGGGG GGWW ST STSTSTSTSTSTSTSTSTS T SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SSSSCTVCTVCTVCTVXXXXXXXXXXXXXXELECWWWWWWWWWWWWWW WPARCEL XWILLOW BROOKPARCEL WWILLOW BROOKPARCEL RWILLOW BROOKPOUDRE R-1SCHOOLDISTRICTPARCEL NO.8604000904KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)STREET B (53' PUBLIC ROW)STREET C(53' PUBLIC ROW)STREET D (53' PUBLIC ROW) QUASAR WAY (53' PUBLIC ROW)STREET A(53' PUBLIC ROW)ECLIPSE LANE(53' PUBLIC ROW)RAINGARDENBRAINGARDENAPOND 1OG1OVERALL GRADING PLAN10 NORTH( IN FEET )1 inch = ft.Feet040404080120G1G2KEYMAPKECHTER RD (C.R. 36)QUASAR WAY ECLIPSELANESheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICTPROPOSED CONTOUREXISTING STORM SEWERPROPOSED STORM SEWERPROPOSED SWALEEXISTING CONTOURPROPOSED CURB & GUTTER PROPERTY BOUNDARYPROPOSED SPOT ELEVATIONPROPOSED SLOPES1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES AREAPPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALLUNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCINGNEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATINGALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALLUNKNOWN UNDERGROUND UTILITIES.2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.3.ALL PROJECT DATA IS ON VERTICAL DATUM NAVD88. SEE COVER SHEET FORBENCHMARK REFERENCES.4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS AREFINISHED GRADE ELEVATIONS.NOTES:PROPOSED STORM INLETEXISTING SPOT ELEVATIONEXISTING LOT LINEPROPOSED CONCRETECROSS PAN (TYP.)EXISTING RIGHT OF WAYPROPOSED LOT LINEPROPOSED RIGHT OF WAYLOT TYPELEGEND:PROPOSED GRADE BREAKCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR VAULT ELEC VAULT ELEC GAS S VAULT ELEC FES CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR LID HY DCONTROL IRR CONTROL IRR CONTROL IRRXX W W WXXXXX XXXXXXXXEEG G G G G G G G GGGGGGGW W W WWWSSSSSS SS X X X X X X X X X X X X X X XXXXXXXXXXXXPARCEL X WILLOW BROOK PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 STREET A ECLIPSE LANEQUASAR WAYSTREET DSTREET B0.531.301.661.921.992.102.392.472.563.002.76 2.88 2.93 3.01 2. 9 7 2.702.56 2.47 2.40 2.32 1.531. 3 5 0.821. 0 01.201.371.621.792.052.222.452.201. 8 3 1.591.220.970. 6 5 0. 5 9 2. 5 0 1.002.752.502. 5 0 2. 5 0 2.502. 5 0 1.002.752.752.752.752.752.752.500.500.350.952.400.75 0.75 1.25 1.50 1.50 2.25 2.25 2.25 (2 . 1 0 )0.500.0699.8699.5999.3999.2598.5398.75(0.94)(0.74)(0.99)(1.12)(1.36)(1 . 9 6 )(2.07)(2.10)(2 . 1 0 )1.35(2.17)(2.60)3.003.50 3.50 4.501. 7 6 2. 2 2(2.97)(2.51)(2.82)(2.91)4.25 2. 2 5 2.252. 2 5 2.253.122. 2 5 2.252.182. 2 5 1. 5 01.331.822.352. 1 5(2.39)(2.32)(2.53)(2.17)(1.91)(1.70)(1.95) (1.99) (2.21) (2.12) (1.85) (1.87) (1.90) (2.11) 2. 2 5 1.751.751.802. 0 02.002.001. 9 8 2. 2 5 2.251.001.030.700. 7 5 FFE=5.00 FFE=5.00 FFE=5.00 FFE=5.00 FFE=4.75 FFE=4.75 FFE=4.75 FFE=4.75 FFE=4.75 FFE=4.75 FFE=2.75 FFE=3.75 FFE=3.75 FFE=3.75 FFE=3.75 FFE=2.25 FFE=4.25 FFE=4.25 FFE=4.25 FFE=4.25 FFE=4.25 FFE=4.25 FFE=0.85 FFE=4.00 FFE=4.00 FFE=4.00 FFE=4.00 FFE=4.00 FFE=4.00 FFE=2.75 FFE=3.50 FFE=3.50 FFE=3.501.08(3.42)2.00(2.26)2. 4 4 1.941.951.771.982.212. 2 51.00(1.98)2. 0 0 (2.33)(1.80)1.052.44GFFE=1.75 GFFE=2.25 GFFE=2.73 GFFE=3.50 GFFE=3.50 GFFE=3.25 GFFE=3.25 GFFE=3.25 GFFE=2.50 GFFE=2.00 GFFE=2.00 GFFE=1.25 GFFE=1.60 GFFE=2.00 GFFE=2.50GFFE=2.75 GFFE=2.25 GFFE=1.85 FFE=3.50 FFE=2.502.502.502. 7 5 2.40 2.40 2.40 2.40 3.503.50 FES INV=4900.57 FES INV=4900.65 FES INV=4901.27 FES INV=4901.22 FES INV=4901.14 FES INV=4901.07 IN-LINE DRAIN RIM=4901.00 INV. IN=4897.21 (N) INV. OUT=4897.21 (S) IN-LINE DRAIN RIM=4901.00 INV. IN=4897.73 (N) INV. OUT=4897.73 (S) IN-LINE DRAIN RIM=4901.00 INV. IN=4898.11 (N) INV. OUT=4898.11 (S) IN-LINE DRAIN RIM=4901.50 INV. IN=4898.49 (W) INV. OUT=4898.49 (S) IN-LINE DRAIN RIM=4901.00 INV. OUT=4899.00 (E) IN-LINE DRAIN RIM=4902.00 INV. OUT=4899.06 (S) IN-LINE DRAIN RIM=4902.00 INV. IN=4898.55 (N) INV. OUT=4898.55 (S) LOT 6 LOT 4 LOT 4LOT 2 LOT 3 LOT 3 LOT 6 LOT 1 LOT 1 LOT 2 LOT 5 LOT 4 LOT 1LOT 4 LOT 4 LOT 2 LOT 3 TRACT D LOT 1 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 TRACT A LOT 5 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6LOT 1 LOT 5 LOT 4 LOT 3 LOT 2 LOT 1 LOT 2 BLOCK 7 BLOCK 1 BLOCK 2BLOCK 8BLOCK 11BLOCK 6IN-LINE DRAIN RIM=4900.50 INV. IN=4897.56 (N) INV. OUT=4897.56 (S) KEYMAP KECHTER RD (C.R. 36)QUASARWAYECLIPSE LANE G1 GRADING PLAN11 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET G2 G1 G2 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 25 All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: PROPOSED STORM INLET EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LOT TYPE LEGEND: PROPOSED GRADE BREAK CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R S VAULT ELEC W FES D S S D E VAULT ELEC T CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTVTTTTT E E E E E E E EXXXXXXXXXXXX XXXE E E E E STSTST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTST SSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSC T V CTV CTV CTV CTV CTV CTV CTV CTV XXXXXELEC WWWWWWWWWWWWWWWWWWWWWWWWWW4:1PARCEL X WILLOW BROOK CITY OF FORT COLLINS PARCEL NO. 8609128901 POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 STREET C STREET DSTREET BKECHTER ROAD (C.R. 36) (70' PUBLIC ROW)97.9098.1598.5198.7698.9599.4099.920.530.821. 0 0 0. 6 9 0. 5 8 0. 2 8 99.8699.80 97.40 98.96 99.65 97.40 99.0099.40(2.42)91.859 3 . 8 5 0.170.340.590.771.200.970.650.320.200.5999.472. 5 0 1. 0 0 1.002.750.500.350.950. 5 0 0.350.350. 5 0 9 9 . 7 1 99.2396.65 96.65 96.65 96.65 96.65 98.15 98.75 0.75 99.75 99.75 0.75 0.75 1.25 1.5099.3999.2598.5398.2297.7897.4798.7597.2597.0096.3996.1195.7395.25(9 6 . 4 3 )(95.93)(96.56)(96.87)(9 8 . 0 8 )(98.60)(0.94)(98.98)(99.52)(0.28)(0 . 7 4 )(0.99)(1 . 1 2 ) (1.90) (2.11) (2.26) (2.30) (1.87) (2.02) (2.25) (2.24) (1.97) 93.85 9 7 . 0 0 91.8591.8597.402. 0 02.062. 2 5 2. 2 5 2. 2 5 2.252.251.600.9897.401. 9 8 2. 2 5 2. 2 5 97.009 7 . 0 0 93.851.0093.85 99.4991.8593.8593.85 1.001.030.700. 7 5 9 9 . 8 4 FFE=3.75 FFE=2.25 FFE=2.25 FFE=2.25 FFE=2.25 FFE=99.65 FFE=0.65 FFE=0.65 FFE=0.65 FFE=0.65 FFE=4.25 FFE=0.85 FFE=2.35 FFE=2.35 FFE=2.35 FFE=2.50 FFE=2.50 FFE=2.50 FFE=1.00 FFE=4.00 FFE=4.00 FFE=0.25 FFE=2.75 FFE=2.75 FFE=2.75 FFE=2.75 FFE=3.50 91.8598.4998.1498.360. 0 7 97.0099.049 1 . 8 591.8593.8597.0095.69 4:193.85 EX DRIPLINE CANOPY (AREA UNDEERNEATH TO REMAIN UNDISTURBED) UPPER DETENTION WALL TO BE RAISED TO MATCH EX GRADE AT DRIPLINE UPPER DETENTION WALL TO BE RAISED TO REDUCE SLOPE FROM ROAD TAPER TOP WALL TAPER TOP WALL 9 7 . 0 091.8593.85 GFFE=98.65 GFFE=99.15 GFFE=99.65 99.0799.3399.670.281.05GFFE=0.25 GFFE=0.75 GFFE=1.75 95.45(9 5 . 8 7 )(97.69)GFFE=1.25 GFFE=0.75 GFFE=0.25GFFE=0.50 GFFE=1.00 GFFE=1.00 GFFE=1.60GFFE=1.85 GFFE=0.85 GFFE=0.85 GFFE=2.32 0. 1 2 99.982.40 0.43 0.500.35EX DRIPLINE CANOPY (AREA UNDEERNEATH TO REMAIN UNDISTURBED) 96.40 CURB INLET RIM=4896.92 INV. OUT=4894.14 (W) CURB INLET RIM=4898.71 INV. IN=4895.55 (N) INV. OUT=4895.30 (S) CURB INLET RIM=4898.53 INV. IN=4895.00 (N) INV. OUT=4892.50 (S) OUTLET STRUCTURE RIM=4897.30 INV. OUT=4892.84 (SW) OUTLET STRUCTURE RIM=4896.70 INV. OUT=4890.42 (S) OUTLET STRUCTURE RIM=4895.10 INV. OUT=4892.30 (E) STORM MH RIM=4897.81 INV. IN=4890.17 (N) INV. OUT=4889.97 (E) INV. OUT=4889.95 (W) FES INV=4894.00 FES INV=4891.85 FES INV=4891.85 FES INV=4891.85 FES INV=4891.85 FES INV=4896.41 IN-LINE DRAIN RIM=4901.00 INV. IN=4896.49 (N) INV. OUT=4896.50 (SW) IN-LINE DRAIN RIM=4901.00 INV. IN=4897.21 (N) INV. OUT=4897.21 (S) IN-LINE DRAIN RIM=4900.43 INV. IN=4897.24 (N) INV. OUT=4897.24 (S) IN-LINE DRAIN RIM=4900.21 INV. IN=4895.86 (N) INV. OUT=4895.86 (S) CURB INLET RIM=4896.92 INV. OUT=4893.57 (E) SIDEWALK CHASE STEPPED WALL STEPPED WALL STEPPED WALL POND 1 BOT EL=4891.85 4-FT WIDE STEP EL=4893.85 TOP EL=VARIES/STEPPED (MIN.=4896.90) OUTLET EL=4896.70 REQUIRED VOL=35,040 CF PROVIDED VOL=37,005 CF RAIN GARDEN A BOT=4894.0 TOP=4895.0 (4:1 SIDES) RAIN GARDEN B BOT=4896.4 TOP=4897.4 (4:1 SIDES) MAINTENANCE ACCESS TRACT B LOT 4 LOT 1 LOT 2 LOT 5 LOT 1 LOT 1 LOT 4 LOT 1 LOT 5 LOT 2 LOT 3 LOT 1 LOT 6 LOT 4 LOT 2 LOT 3 LOT 1 LOT 3 LOT 2 LOT 3 LOT 4 LOT 5 TRACT C LOT 2 LOT 3 LOT 4 LOT 1 BLOCK 3BLOCK 4BLOCK 9BLOCK 10BLOCK 5IN-LINE DRAIN RIM=4900.50 INV. IN=4897.56 (N) INV. OUT=4897.56 (S) KEYMAP KECHTER RD (C.R. 36)QUASARWAYECLIPSE LANE G2 GRADING PLAN12 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET G1 G1 G2 SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 25 All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. NOTES: PROPOSED STORM INLET EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LOT TYPE LEGEND: PROPOSED GRADE BREAK CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R STREET ASTREET CSTREET D QUASAR WAY LOT 6LOT 4LOT 4LOT 2LOT 3LOT 1LOT 1LOT 4LOT 4LOT 2LOT 3TRACT DLOT 1LOT 5LOT 2LOT 3LOT 1LOT 2LOT 5LOT 1LOT 1LOT 2LOT 3LOT 4LOT 5LOT 6LOT 4LOT 2LOT 3LOT 1LOT 5LOT 4LOT 3LOT 2LOT 3LOT 2LOT 1TRACT CLOT 2LOT 3LOT 4LOT 1BLOCK 7BLOCK 4BLOCK 9BLOCK 10BLOCK 5BLOCK 8BLOCK 11BLOCK 6PC: 4+70.80PT: 5+27.80 VAULTELECGASSF ESCONTROLIRRCONTROLIRRSVAULTELECWSXCTVCTVCTVCTVCTVEEXEGG GGWWSTSTSTST STSTSS SSSSSSSSSSSSSSSSCTVCTVCTVCTVXXXXELECWWWWWWKECHTER ROAD (C.R. 36)(70' PUBLIC ROW)LEFT TURN LANETHRU LANETHRU LANE13.711.016013.14890 4895 4900 4905 4910 4915 4890 4895 4900 4905 4910 4915 0+00 1+00 2+00 3+00 4+00 5+00 6+00 52.4' VC LP ELEV = 4897.31 LP STA = 0+37.80 PVI STA = 0+49.00 PVI ELEV = 4897.22 BCVS: 0+22.80BVCE: 4897.35ECVS: 0+75.21EVCE: 4897.55A.D. = 1.75 K = 30.00 105.3' VC HP ELEV = 4903.10 HP STA = 5+51.46 PVI STA = 5+41.74 PVI ELEV = 4903.36 BVCS: 4+89.10BVCE: 4902.71EVCS: 5+94.38EVCE: 4902.91A.D. = 2.11 K = 50.00 1.25% -0.50%-2.00% -2.34%2.34% -0.86% EXISTING GROUND PROPOSED GRADE 8' WIDE VALLEY PAN KEYMAP KECHTER RD (C.R. 36)QUASARWAYECLIPSE LANE R1 PLAN & PROFILESTREET D & STREET A13 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CENTERLINE STREET D/STREET A SCALE : 1" = 40' (H) 1" = 4' (V)R1R2STAMATCH LINESEE SHEET6+00R2SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 25 All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET MATCH STA 6+00LINE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R STREET ASTREET CSTREET D QUASAR WAY STREET B LOT 6TRACT BLOT 4LOT 3LOT 1LOT 1LOT 4LOT 1LOT 2LOT 3LOT 4LOT 5LOT 1LOT 2LOT 3LOT 4LOT 5LOT 6LOT 4LOT 2LOT 3LOT 1LOT 5LOT 4LOT 3LOT 2LOT 3LOT 2BLOCK 7BLOCK 1BLOCK 9BLOCK 10BLOCK 8BLOCK 11PC: 4+70.80PT: 5+27.80 PC: 6+30.36 PT: 6+83.21PC: 9+54.12PT: 10+09.11 VAULTELECGASSVAULTELECWCTVCTVCTVCTVCTVCTVEEEEGGGG GGWWSTST STSTSTSTSSSSSSSSSSSSSSSSCTVCTVCTVXXXXELECWWWWWW13.711.021213.14890 4895 4900 4905 4910 4915 4890 4895 4900 4905 4910 4915 6+00 7+00 8+00 9+00 10+00 11+00 11+68 2.00% 8.75%-8.75% -0.86% EXISTING GROUND PROPOSED GRADE 6' WIDE VALLEY PAN KEYMAP KECHTER RD (C.R. 36)QUASARWAYECLIPSE LANE R2 PLAN & PROFILESTREET B & STREET C14 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CENTERLINE STREET B/STREET C SCALE : 1" = 40' (H) 1" = 4' (V)R1R2SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 25 All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLETSTA MATCH LINESEE SHEET6+00R2MATCH STA 6+00LINE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R STREET AQUASAR WAY LOT 6LOT 4LOT 2LOT 3LOT 1LOT 2LOT 3LOT 4LOT 1LOT 2LOT 3LOT 4LOT 5LOT 5LOT 4LOT 3LOT 2BLOCK 7BLOCK 1BLOCK 8BLOCK 11R=165'VAULTELECGASSVAULTELECEGGG GGWW SSSSXXXX4890 4895 4900 4905 4910 4915 4890 4895 4900 4905 4910 4915 0+00 1+00 1+44 EXISTING GROUND PROPOSED GRADE -1.61% -2.00% -2.31%2.31% 2.03% 25.7' VC HP ELEV = 4904.45 HP STA = 0+93.71 PVI STA = 0+92.21 PVI ELEV = 4904.56 BVCS: 0+79.37BVCE: 4904.30EVCS: 1+05.06EVCE: 4904.36A.D. = 3.64 K = 7.06 6' WIDE VALLEY PAN R3 PLAN & PROFILEQUASAW WAY & ECLIPSE LANE15 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CENTERLINE QUASAR WAY SCALE : 1" = 40' (H) 1" = 4' (V)R1R2KEYMAP KECHTER RD (C.R. 36)QUASARWAYECLIPSE LANE SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 25 All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)EXISTING BIKE LANEEXISTING BIKE LANEEXISTING THRU LANEEXISTING THRU LANE7.412.711.013.27.5EXISTINGSTRIPING7EXISTING 11' LEFT TURN LANE ONTO LADY MOON71KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)7717EXISTING STRIPING(TO BE REMOVED)7LAEXISTING STRIPINGEXISTING BIKE LANEEXISTING BIKE LANEEXISTING THRU LANEPROPOSED THRU LANEPROPOSED TURN LANE17.712.411.013.96.9XEXISTING STRIPING(TO BE REMOVED)LA777EXISTING BIKE LANEEXISTING BIKE LANEEXISTING THRU LANEPROPOSED THRU LANEPROPOSED TURN LANEKECHTER ROAD (C.R. 36)(70' PUBLIC ROW)1111716.913.011.014.06.810.25.514.614.07.4EXISTING TURN LANEEXISTING BIKE LANEEXISTING THROUGH LANEEXISTING THROUGH LANEEXISTING BIKE LANEPROPOSED THROUGH LANEEXISTING BIKE LANEPROPOSED THROUGH LANEPROPOSED BIKE LANER4RE-STRIPING PLAN KECHTER ROAD16 NORTH( IN FEET )1 inch = ft.Feet02020204060KEYMAPKECHTER RD (C.R. 36)QUASAR WAY ECLIPSELANESheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICTCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRMATCH LINE - SEE TOP RIGHT MATCH LINE - SEE BOTTOM LEFT MATCH LINE - SEE TOP RIGHT MATCH LINE - SEE BOTTOM LEFT LEGEND:/ / / / / / / /PROPOSED EDGE OF ASPHALTCENTERLINEPEDESTRIAN ACCESS RAMPSPROPOSED CONCRETECROSSPAN (TYP.)RIGHT-OF-WAYNOTES:LOT LINE1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES AREAPPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALLUNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEWCONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALLUNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWNUNDERGROUND UTILITIES.2.REFER TO LANDSCAPE PLANS FOR STREET TREE INFORMATION, AND SURVEYDOCUMENTS FOR ADDITIONAL RIGHT-OF-WAY AND EASEMENT INFORMATION.3.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THEDEVELOPER SHALL PLACE TEMPORARY TABS OR TAPE DEPICTING ALIGNMENT ANDPLACEMENT OF THE SAME. THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OFFORT COLLINS AND TOWN OF TIMNATH TRAFFIC ENGINEERS PRIOR TO PERMANENTINSTALLATION OF STRIPING AND SYMBOLS.YELLOW ISLAND CROSS HATCHING10WHITE ISLAND CROSS HATCHING4" SOLID YELLOW LINE6" SOLID WHITE LINE(2) 4" SOLID LINES; 4" APARTDOUBLE YELLOW LINE4" BROKEN YELLOW LINE8" SOLID WHITE LINEDOUBLE YELLOW LINE4" SOLID AND 4" BROKEN; 4" APART963518247STRAIGHT AND RIGHT TURN ARROW (31 S.F. EA.)PREFORMED PLASTIC PAVEMENT MARKINGBICYCLIST AND ARROW18" X 12' CROSSING LINE, SEE NOTESPREFORMED PLASTIC PAVEMENT MARKINGPREFORMED PLASTIC PAVEMENT MARKING18" WIDE STOP BARPREFORMED PLASTIC PAVEMENTMARKING "STOP" (22.5 S.F. EA.)PREFORMED PLASTIC PAVEMENT MARKINGSTRAIGHT AND LEFT TURN ARROW (31 S.F. EA.)PREFORMED PLASTIC PAVEMENT MARKINGPREFORMED PLASTIC PAVEMENT MARKINGRIGHT TURN ARROW (15.5 S.F. EA.)PREFORMED PLASTIC PAVEMENT MARKINGLEFT TURN ARROW (15.5 S.F. EA.)RIGHT AND LEFT TURN ARROW (31 S.F. EA.)PREFORMED PLASTIC PAVEMENT MARKINGTWO WAY LEFT TURN ARROW (31 S.F. EA.)PREFORMED PLASTIC PAVEMENT MARKINGPREFORMED PLASTIC PAVEMENTMARKING "ONLY" (22.5 S.F. EA.)LHDCBKAEFGIJMLANE REDUCTION ARROWPREFORMED PLASTIC PAVEMENT MARKINGMEDIAN LINE YELLOW 18" WIDE1150' O.C. 45° ANGLES10'30'10'30'10'4" BROKEN WHITE1210'N"LANE ENDS"PREFORMED PLASTIC PAVEMENT MARKING3'9'3'9'3'4" WHITE DASHED LINEO18" WIDE WHITE MEDIAN STRIPINGPREFORMED PLASTIC PAVEMENT MARKINGA.ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL NOTES ON THE COVER SHEET OF THESE PLANS, AS WELL ASTHE TRAFFIC SIGNING AND MARKING CONSTRUCTION NOTES LISTED HERE.B.ALL SYMBOLS, INCLUDING ARROWS, ONLYS, CROSSWALKS, STOP BARS, ETC. SHALL BE PRE-FORMEDTHERMO-PLASTIC.C.ALL SIGNAGE SHALL BE PER TOWN OF TIMNATH AND CITY OF FORT COLLINS STANDARDS AND THESE PLANS OR ASOTHERWISE SPECIFIED IN MUTCD. (REF. LCUASS SECTION 22.6.2)D.ALL LANE LINES FOR ASPHALT PAVEMENT SHALL RECEIVE TWO COATS OF LATEX PAINT WITH GLASS BEADS.E.ALL LANE LINES FOR CONCRETE PAVEMENT SHALL BE EPOXY PAINT.F.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THE DEVELOPER SHALL PLACETEMPORARY TABS OR TAPE DEPICTING ALIGNMEMT AND PLACEMENT OF THE SAME. THEIR PLACEMENT SHALL BEAPPROVED BY THE CITY OF FORT COLLINS AND TOWN OF TIMNATH ENGINEERS PRIOR TO PERMANENT INSTALLATIONOF STRIPING AND SYMBOLS.G.PRE-FORMED THERMO-PLASTIC APPLICATIONS SHALL BE AS SPECIFIED IN THESE PLANS AND/OR THESE STANDARDS.H.EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGECONSTRUCTION.I.ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS.J.ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE STANDARDS.K.A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED BY THE CITY OF FORTCOLLINS AND TOWN OF TIMNATH ENGINEERS. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD INSPECTION MUSTBE CORRECTED BEFORE THE 2-YEAR WARRANTY PERIOD WILL BEGIN.L.THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUNDUTILITIES.M.SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN.N.SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME OF REVIEW. PRIOR TOINITIATION OF THE WARRANTY PERIOD, THE CITY OF FORT COLLINS AND TOWN OF TIMNATH RESERVE THE RIGHT TOREQUIRE ADDITIONAL SIGNAGE AND/OR STRIPING IF THE CITY OF FORT COLLINS AND TOWN OF TIMNATH DETERMINETHAT AN UNFORESEEN CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND SSTANDARDS. ALL SIGNAGE AND STRIPING SHALL FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIODFOR NEW CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS).O.SLEEVES FOR SIGN POSTS SHALL BE REQUIRED FOR USE IN ISLANDS/MEDIANS. REFER TO CHAPTER 14, TRAFFICCONTROL DEVICES, FOR ADDITIONAL DETAIL.P.STREET NAME SIGNS AT INTERSECTIONS SHALL BE INSTALLED ABOVE STOP SIGNS ON SAME POLE, PER LCUASSDRAWING 1401.STRIPING LEGEND:STRIPING NOTES:3'9'3'9'3'8" WHITE DASHED LINE(NOTE: ALL ITEMS MAY NOT APPLY TO THIS PLAN)PAVEMENT STRIPINGPAVEMENT MARKINGSSTRAIGHT ARROW (15 S.F. EA.)PREFORMED PLASTIC PAVEMENT MARKING30'10'30'10'EASEMENTR4 D1SITE DETAILS17CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRSheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICT100CURB AND GUTTER101103104STREET INTERSECTION CROSSPANASPHALT PAVING DETAIL (CROSSPAN)105SIGN POST1061076"2"R.2"6"6"12"1 1/2"R.2'-6"6"4 1/2"30"9"R 0.5"4.5"18"3.63"21.75"R 0.13"7"2"3.75"12"ROLL-OVERVERTICAL(LOVELAND)Gutter edge may betapered or battered.(Typical for all Curb && Gutter Types)SECTION A-A PAVEMENT DESIGN + 1/2" FOR COLLECTOR 8" MIN. FOR RESIDENTIAL. USE CONCRETE 10' MINIMUM (ARTERIAL) 8' MINIMUM (COLLECTOR) PLAN VIEW 6' MINIMUM (LOCAL) COLD JOINT (See Standard Drawing 714) AT 10' O.C. TOOL JOINT FOR PANS OVER 40' CONTROL JOINT REQUIRED CONTROL ROADWAY WIDTH ALL INTERSECTIONS TO HAVE ACCESS RAMPS NOTE:**& ARTERIALS. SIDES. TO PAN SECTION, TYPICAL BOTH TRANSITION FROM C & G SECTION WALK 8' DOWELL IF JOINTS TOOL JOINTA A JOINTS (TYP.) CONTROL PARALLEL STREET CLASSIFICATION LOVELAND DEPTH OF INVERT W WIDTH CROSS PAN Arterial 10'1 1/4"1 1/2" Collector 8'1"1 1/8" Local 6'3/4"7/8" d (MAX.)d (MIN.) 1 1/2" 2 1/2" 2" DEPTH OF INVERT FT. COLLINS d d 8' MIN. WIDTH WHERE CROSSING A COLLECTOR ROADWAY.**** LENGTH (for monolithic pour)THICKNESSASPHALTDESIGNED2T*WASPHALT2T*WTW P.C.CROSSPANTHICKENEDASPHALTTHICKENEDASPHALTTHICKNESSDESIGNEDAND WALKCURB, GUTTERT = THICKNESS OF CROSSPANW = WIDTH OF CROSSPANP.C.*-If subgrade is flyash treated, use T instead of 2T.Max. Sign Panel1. Attach the sign panels tightly to the post and use oversized washers to keep the sign from breaking loosefrom the post when hit by a vehicle.2. Sign panels should be mounted a minimum of 7 feet above the pavement or ground.Cross section of post3" - 6" ABOVE GRADE2 1/4" Anchor3. Signs larger than 36 inches in length or width require wind bracing and special post design.NOTES:4. Anchor Stub and post are square steel tube (perforated).Anchor/StubPost SizeCRITERIA FOR SINGLE POST36" x 36"2.25" x 2.25" x 3'-0"2" x 2" x 12'-0"5. All "No Parking" signs shall be installed at 45° from Flow Line.**2" x 2" x 10' OR 12'12 GAUGE TELESPAR POST(22F12A31)7'-0" MIN. CLEARANCE2' - 3'FROM FStreet CurbSee Figure 16-1SWSAMPLEAVE2400R1-1 "STOP" SIGN 30" HIGH DENSITY/DIAMONDGRADE. SIGN MOUNTED TO POST WITH 1 EACHDRIVE RIVET WITH NYLON WASHER AGAINST SIGNFACE (ON TOP OF THE SIGN). THE BOTTOM OF THESIGN SHALL BE MOUNTED WITH 1 EACH5/16"x2-1/2" HEW BOLT WITH METAL AND FROMNYLON WASHERS (NYLON WASHER AGAINST SIGNFACE) AND SECURED WITH 1 EACH 5/16" HEX NUTON THE BACK SIDE OF POST.L2-1/4" x 2-1/4" x 3'ANCHOR/STUB2 EACH 8" BLADESMOUNTED TO POSTWITH 4 EACH DRIVERIVETS WITHNYLON WASHERS*12 Gauge30"8"8"or equivalent. (typical both sides)With curb walk, cover plate extendsfrom property line to top of walk face.6" VERTICAL CURB, GUTTER, AND SIDEWALKSECTION A-A (2 VIEWS)COMBINATION CURB, GUTTER, AND SIDEWALKcenter, Nelson Standard Anchor3" #4 Bar Welded at 12" onL = 1 1/4" x 1 1/4" x 1/4"5/8" Rolled Steel Tread PlateSECTION C-C1.0' (minimum) approved by the Engineer. Right of Way line to flow line unless2. Chase and cover plate run from1. Length of steel plate varies.Notes:Dimension Variable(diamond pattern)5/8" Rolled Steel Tread Plate4'-0" or as DirectedRetaining Screws atTop of Curb CBABCPLAN VIEWAStreet SECTION B-B10 3/8"6"1 1/4"AttachedFt. Collins onlyDetached Sidewalkfinish 12" on centerScrew Brass or Electro-galv.1/2" x 1" Flat Head Mach.threaded to receive screw.Angle iron to be drilled andscrew to extend into theConcrete to be drilled to allowLip of Gutter concrete(typical both sides).(typical both sides)LF Sidewalk X (Varies, See PlansXmax=2.0')d (Varies,See Plans)DRAINAGE UNDER SIDEWALK7 3/8" (L)1 3/8"17"6"3 3/8"14"FL R 16"R 16"DRIVE-OVER CURB, GUTTER AND DETACHED SIDEWALK31"See Drawing 160110 3/4"(L)R 16"DRIVE-OVER CURB, GUTTER AND ATTACHED SIDEWALK 18"18"3 3/8"1 3/8"6"R 16"FL 14"6"17" 1 1/2" 5' (L)8 5/8" (F.C.)7 1/4" F.C.12" (F.C.)Slope to curb 1/4"/Ft.1' min. (F.C.)48:1 min.4:1 max. Excavation Fill 1' min. 2' min. 1/4"/Ft. CURB & GUTTER IN A CUT OR FILL 6"3'-9" (F.C.) For Thickness2' min. (L)CURB AND GUTTER / SIDEWALKSTANDARD SIDEWALKDrivewayDrivewaySidewalkSECTION A-ADetached SidewalkAttached SidewalkAttachedDetachedAll Sidewalk Thickness Shall Be 6" minimum.SidewalkNOTE:1. Sidewalk grade shall remain consistent across driveway2. For driveway design requirements, see CONST. DWG. Series 706 & 7073. This detail applies to Residential & Commercial driveways.6"2'-0"6'-0"T.C.F.L.Lip1/2" ExpansionJoint Material1/2" ExpansionJoint Material8" Commercial6" ResidentialAASidewalkMin. D2SITE DETAILS18SheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICT200201202203SIDEWALK DETAILSTREET ACCESS RAMPSTRUNCATED DOME WARNINGDIRECTIONAL ACCESS RAMP DETAIL& DETACHED SIDEWALKATTACHED SIDEWALK DETAILSlope sidewalk to curb 1/4" per foot.NOTE: Construct sidewalk with joints at 10' intervalsR 1/8"WEAKENED PLANE JOINTEXPANSION JOINTR1/4"and aligned with scoring on curb.INSTALL IN LOCATIONS SPECIFIEDIN CHAPTER 221/2"1/4"1/4 SLAB THICKNESS1/4"1/2" ExpansionJoint materialDETACHED SIDEWALK DETAILVariableLandscapingSlope sidewalk to curb 1/4" per foot.2' min.Slope: Minumum 14"/ft Maximum 3"/ftRadius = 8"1. No joints are allowed in the flowline. Six inch wide curb or "dummy joint" may be tooled no closer than 6 inchesfrom flow line as shown.2. Pedestrian landing area required 4 ft length x 4 ft width, max slope in any direction is 1:50 or 14" per foot.3. Joint pattern to be according to intersection gutter detail' or as determined by the local entity.4. Wood float finish is required over the sloped surface of ramp and flares.5. A 6" wide curb option may be poured along side of the ramp as shown if required. If curb is used it shall matchstyle of adjacent curb and gutter.6. Minimum ramp width shall be four feet, or the same as the widest adjacent sidewalk, whichever is greater, up to amaximum width of 8 feet.7. Detectable warning is to extend full width of the ramp and be a minimum of 2.0' in the direction of travel. Materialto be approved by local engineer8. T = Concrete thickness, 6" minimum for entire ramp area.SECTION A-APLAN VIEWN.T.S.N.T.S.NOTES:2' Transition (TYP.)4' (min)6"2'1:20 (max)1:12 (max)T, See Note 80" CurbLip of GutterDetectableWarningAA1/2" per ft.1" per ft.FlareCurbFlareDetectable WarningCurb Option,See Note 5Curb (TYP.)SIDEWALKSIDEWALK 0" Curb Height,See Section A-A(TYP)Standard Curband Gutter,See StandardDwg 701 (TYP)PedestrianLanding Area,See Note 22' (min)FORT COLLINS ONLYNotes: 1. Set ramp slopes using the center of the ramp. 2. Truncated dome warning panel: Install panels along with the concrete pour for the ramp. Specifications for the panel material will be provided upon request. 3. Each ramp shall align perpendicular to the street in which the ramp is provided to cross. 4. Refer to standard drawing 1606 in the Laimer County urban area street standards for other necessary criteria needed to construct these ramps that is not specified on this drawing. 5. Construct the ramps and walk so the corner area all drains to the street. 6. If curb and gutter are poured monolithic with ramp, place dome edge at back of curb as shown. If not poured monolithic, place dome edge 6" from back of curb. PLAN VIEW NTS RampFlare Gutter Ramp Ramp Flare Curb Curb Conc. Flare PanelsPanels Truncated dome panels: 1-2'x2.5' 1-2'x2' Truncated Dome Warning Detection Plan Locations LEGEND: BOC- Back of curb ⅊ Property Line PT - Point of TangencyFlow lineSection A-A NTS 4'-6"2'-0"2'-6" 2'-0"tVariesVaries4.5' 6.0' .5' 1.5'4.5'1.5 ' 12.0' 12.0' 4.5' .5' 6.0'4.5'Landscaped AreaPT Curb A A 6" Curb (TYP) 0" Curb Full height curb Truncated dome warning detection ⅊ PT of walk R15.0' ⅊ ⅊ & BOW 5'-6" BOC to walk w/ vertical curb 5'-7" BOC to walk w/ drive over curb Conc. Sidewalk Area to be landscaped Conc. walk Gutter or Apron Truncate Dome Warning Panel 1:12 Max slope1:20 Slope PT of curb return 6" Conc. Flare 6" Curb (TYP)See note 6CurbFlareVariesCurbFlareRamp Curb CurbFlareRampVariesPanelsPanels6"RampWidth:4.5'5.0'6.0'7.0'8.0'Note:Truncated dome panels areavailable in 2'x2' squaresand 2'x2.5' rectangles.Combine the widths to fitthe ramp. Panels may becut to no less than a 2'x1.5'size.Panel WidthCombinations:2'+2.5'2.5'+2.5'2'+2'+2'2.5'+2'+2.5'2'+2'+2'+2'Notes: 1. Truncated dome warning panel: Install panels along with the concrete pour for the ramp. Specifications for the panel and installation instructions will be provided upon request. 2. This drawing shows vertical curb.For Drive Over Curb the warning detection location shall be placed inthe same position 6" back from theback of curb. 3. If curb and gutter are poured monolithic with ramp, place domeedge at back of curb as shown. Ifnot poured monolithic, place domeedge 6" from back of curb.Case 1-Directional Ramps Case 2-Non-Directional Ramps VariesPanelsRampPanels FlareCurbCase 3-Mid-Block Ramps6"Panels Panels Flare 6"FlareVaries FORT COLLINS ONLYAligned withPedestrian flowGutterorApron ℄Center line of rampBOC-Back of CurbFOC -Face of Curb-Flow lineVaries2'-0"2'-0"AAFOC or ℄2'-0"BOC BOC1:12 max slope1:20slope Panels embedded in theconcrete ramps Section A-A (Center line of ramp)NTSFlow line Curband GutterBOCSee Note 3CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR D3UTILITY DETAILS19SheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICT300TRENCH AND BEDDING301302303GATE VALVESINGLE METER PIT304305FIRE HYDRANTDOUBLE METER PITUTILITY SERVICE LOCATIONCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR D4UTILITY DETAILS20SheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICT300301302303OUTSIDE-DROP MANHOLETYPICAL MANHOLEGROUNDWATER BARRIERC:\Work\MAPPING\BLOCKS\Logos\SS-New\SFCSD.bmp304305SANITARY SEWER SERVICE CONNECTIONTRENCH AND BEDDINGUTILITY SERVICE LOCATIONCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR D5DRAINAGE DETAILS21SheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICT500CURB OPENING501502CURB OPENING REINFORCEMENTMETAL CULVERTMETAL END SECTIONSPLAN VIEWSECTION A-ASECTION B-BGENERAL NOTES:BAABDETAIL "A"303305BACK OF CURBEDGE OF STREET58" GALV. STEEL PLATE21213"x2"x38" GALV. ANGLESEE DETAIL 1#4@12"O.C.#4@12"O.C.#4@12"O.C.3"x2"x38"GALV. ANGLE58" GALV.STEEL PLATE#3 REBARANCHOR18 O.C.38" BRASS SCREW18 O.C. WITHCOUNTERSUNK HEADFLUSH WITH PLATE6" 6"VARIES2'3'SECTION B-BDETAIL 1SECTION A-APLANSECTION C-CSLOPEVARIES0.5% SLOPE (MIN.)VARIESVARIES2' DEPRESSED GUTTERVARIES EXPANSIONMATERIAL58" GALV.STEELPLATEEDGE OFSTREET12" R12" R2' OPENING3'-3"3'-3"6" (TYP.)BACKOFCURB3" (TYP.)3' (TYP.)SIDEWALK (TYP.)EXTEND WALK 6" ONBOTH SIDES OF WALKVARIESVARIES SLOPE CCBBAA8'-6"EXPANSIONMATERIAL38" BRASS SCREW 18" O.C.WITH COUNTERSINKHEAD FLUSH WITH PLATE2'6"304SIDEWALK CHASEAABBAASINGLE CURB INLETCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR VAULTELECVAULTELECGASSVAULTELECFESCONTROLIRRCONTROLIRR CONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRLIDSVAULTELECFESDSSSSCONTROLIRRCONTROLIRRCONTROLIRRDEVAULTELECTVAULTELECCXX XXXXXX XXXXXXXXXXXXXXXXXXELECT T TT E E EEEE TTE E E E E E EE TT TEEEEEEEEEEEEEEEEEEE E E E E E E EEE EE EEEEEEEEEEETCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CFCFCFCFCFCFPARCEL XWILLOW BROOKPARCEL WWILLOW BROOKPARCEL RWILLOW BROOKPOUDRE R-1SCHOOLDISTRICTPARCEL NO.8604000904ECLIPSE LANE(53' PUBLIC ROW)KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)STREET B (53' PUBLIC ROW)STREET C(53' PUBLIC ROW)STREET D (53' PUBLIC ROW) QUASAR WAY (53' PUBLIC ROW)STREET A(53' PUBLIC ROW)SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFEC1OVERALL EROSION CONTROL PLAN22 NORTH( IN FEET )1 inch = ft.Feet040404080120SheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICTKEYMAPKECHTER RD (C.R. 36)QUASAR WAY ECLIPSELANEEC2EC3LEGEND:PROPOSED CONTOURPROPOSED STORM SEWERPROPOSED SWALEEXISTING CONTOURPROPOSED CURB & GUTTERPROPERTY BOUNDARYPROPOSED INLETROCK SOCKINLET PROTECTIONVEHICLE TRACKING CONTROL PADSILT FENCESF1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BYCRIMP MULCHING OR SIMILAR METHODS.2.SWMP ADMINISTRATOR:Contact________________________________Company________________________________Address________________________________Phone________________________________3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETEWASHOUT AREA IF ACCESS IS OFF PAVEMENT.4.REFER TO THE "PRELIMINARY DRAINAGE AND EROSION CONTROL REPORTFOR "KECHTER TOWNHOMES" BY NORTHERN ENGINEERING, DATED JULY 22,2020 FOR ADDITIONAL INFORMATION.5.HYRDOMULCH ALL SLOPES 6:1 OR GREATER WHERE RUNON IS ANTICIPATEDOR SLOPE AREA IS LONGER THAN 50'. INSTALL ECF WHERE HYDROMULCHDOES NOT CONTROL EROSION TO THE SATISFACTION OF THE INSPECTOR.6.SEDIMENTATION BMP FREQUENCY IS SCHEMATIC. ADD BMPs AS NEEDED TOENSURE NO GREATER THAN 2% SLOPE FROM BOTTOM OF UPSTREAM TO TOPOF DOWNSTREAM STRUCTURE.GENERAL NOTES:WATTLE DIKECONCRETE WASH AREAOUTLET PROTECTIONCONSTRUCTION FENCECFCFCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR VAULTELECVAULTELECGASSVAULTELECFESCONTROLIRRCONTROLIRR CONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRCONTROLIRRLIDCONTROLIRRCONTROLIRRCONTROLIRRXXX X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXT T TT E E E E EEEEEEE E TETEE E E E E E E E E E E E EEE E E EEEEE E E E EEE ESTREET ACFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CFCFCFCFCFCFCFCFCFCFCFCF LOT 6LOT 4LOT 4LOT 2LOT 3LOT 3LOT 6LOT 1LOT 1LOT 2LOT 5LOT 4LOT 1LOT 4LOT 4LOT 2LOT 3TRACT DLOT 1LOT 1LOT 2LOT 3LOT 4LOT 5TRACT ALOT 5LOT 1LOT 2LOT 3LOT 4LOT 5LOT 6LOT 1LOT 5LOT 4LOT 3LOT 2LOT 1LOT 2BLOCK 7BLOCK 1BLOCK 2BLOCK 8BLOCK 11BLOCK 6STREET D STREET B 6' UTILITY &DRAINAGEEASEMENT6' DRAINAGEEASEMENT9' UTILITY EASEMENTPARCEL XWILLOW BROOKPARCEL WWILLOW BROOKPARCEL RWILLOW BROOKPOUDRE R-1 SCHOOL DISTRICTPARCEL NO. 8604000904ECLIPSE LANEQUASAR WAY SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFEC2EROSION CONTROL PLAN23 NORTH( IN FEET )1 inch = ft.Feet02020204060SheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICTKEYMAPKECHTER RD (C.R. 36)QUASAR WAY ECLIPSELANEEC2EC3MATCH LINE - SEE SHEET EC3LEGEND:PROPOSED CONTOURPROPOSED STORM SEWERPROPOSED SWALEEXISTING CONTOURPROPOSED CURB & GUTTERPROPERTY BOUNDARYPROPOSED INLETROCK SOCKINLET PROTECTIONVEHICLE TRACKING CONTROL PADSILT FENCESF1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BYCRIMP MULCHING OR SIMILAR METHODS.2.SWMP ADMINISTRATOR:Contact________________________________Company________________________________Address________________________________Phone________________________________3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETEWASHOUT AREA IF ACCESS IS OFF PAVEMENT.4.REFER TO THE "PRELIMINARY DRAINAGE AND EROSION CONTROL REPORTFOR "KECHTER TOWNHOMES" BY NORTHERN ENGINEERING, DATED JULY 22,2020 FOR ADDITIONAL INFORMATION.5.HYRDOMULCH ALL SLOPES 6:1 OR GREATER WHERE RUNON IS ANTICIPATEDOR SLOPE AREA IS LONGER THAN 50'. INSTALL ECF WHERE HYDROMULCHDOES NOT CONTROL EROSION TO THE SATISFACTION OF THE INSPECTOR.6.SEDIMENTATION BMP FREQUENCY IS SCHEMATIC. ADD BMPs AS NEEDED TOENSURE NO GREATER THAN 2% SLOPE FROM BOTTOM OF UPSTREAM TO TOPOF DOWNSTREAM STRUCTURE.GENERAL NOTES:WATTLE DIKECONCRETE WASH AREAOUTLET PROTECTIONCONSTRUCTION FENCECFCFTYP.CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRTYP. SVAULTELECF ESDSSDEVAULTELECTXXXXXXXXXXXXXXXXXXXXELECT T TEE E ETT TEEEEEEEEEEEEEEEEEEEEE E E E E E E E E E E E E E E EEEEE EEE EEEEEEEEEEEEEEEEEEEEEEETSTREET CSTREET D CFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCFCF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF TRACT BLOT 4LOT 1LOT 2LOT 5LOT 1LOT 1LOT 4LOT 1LOT 5LOT 2LOT 3LOT 1LOT 6LOT 4LOT 2LOT 3LOT 1LOT 3LOT 2LOT 3LOT 4LOT 5TRACT CLOT 2LOT 3LOT 4LOT 1BLOCK 3BLOCK 4BLOCK 9BLOCK 10BLOCK 5STREET B 14' DRAINAGEEASEMENT9' UTILITY EASEMENT9' UTILITY EASEMENT9' UTILITY EASEMENTPARCEL XWILLOW BROOKCITY OF FORT COLLINSPARCEL NO. 8609128901POUDRE R-1 SCHOOL DISTRICTPARCEL NO. 8604000904KECHTER ROAD (C.R. 36)(70' PUBLIC ROW)SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFEC3EROSION CONROL PLAN24 NORTH( IN FEET )1 inch = ft.Feet02020204060SheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICTKEYMAPKECHTER RD (C.R. 36)QUASAR WAY ECLIPSELANEMATCH LINE - SEE SHEET EC2TYP.LEGEND:PROPOSED CONTOURPROPOSED STORM SEWERPROPOSED SWALEEXISTING CONTOURPROPOSED CURB & GUTTERPROPERTY BOUNDARYPROPOSED INLETROCK SOCKINLET PROTECTIONVEHICLE TRACKING CONTROL PADSILT FENCESF1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BYCRIMP MULCHING OR SIMILAR METHODS.2.SWMP ADMINISTRATOR:Contact________________________________Company________________________________Address________________________________Phone________________________________3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETEWASHOUT AREA IF ACCESS IS OFF PAVEMENT.4.REFER TO THE "PRELIMINARY DRAINAGE AND EROSION CONTROL REPORTFOR "KECHTER TOWNHOMES" BY NORTHERN ENGINEERING, DATED JULY 22,2020 FOR ADDITIONAL INFORMATION.5.HYRDOMULCH ALL SLOPES 6:1 OR GREATER WHERE RUNON IS ANTICIPATEDOR SLOPE AREA IS LONGER THAN 50'. INSTALL ECF WHERE HYDROMULCHDOES NOT CONTROL EROSION TO THE SATISFACTION OF THE INSPECTOR.6.SEDIMENTATION BMP FREQUENCY IS SCHEMATIC. ADD BMPs AS NEEDED TOENSURE NO GREATER THAN 2% SLOPE FROM BOTTOM OF UPSTREAM TO TOPOF DOWNSTREAM STRUCTURE.GENERAL NOTES:WATTLE DIKECONCRETE WASH AREAOUTLET PROTECTIONCONSTRUCTION FENCECFCFTYP.EC2EC3CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR EC4EROSION CONROL DETAILS25SheetKECHTER TOWNHOMES These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 25All changes, addendums, additions, deletions andmodifications to these drawings must be approved,in writing, by the Fort Collins-LovelandWater District and the South Fort Collins Sanitation District.District EngineerDateFORT COLLINS - LOVELANDWATER DISTRICTSOUTH FORT COLLINSSANITATION DISTRICT000SILT FENCE001002003CONSTRUCTION FENCEVEHICLE TRACKING CONTROL PADINLET PROTECTION004WATTLE DIKE005OUTLET PROTECTIONTEMPORARYCHAIN-LINK FENCEROCK SOCKTEMPORARYCHAIN-LINK FENCEROCK SOCKSIDE VIEWCFXCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR GAS CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR S VAULT ELEC W FE S D S SS HY DCONTROL IRR CONTROL IRR CONTROL IRR D E VAULT ELEC T VAULT ELECCXGTTE EWW W W W W WT T T E E E E E XXXXXXXXXXXXXXE E EX G G G G G GWST ST ST ST ST ST ST ST ST ST ST ST STSTSS SS SS SS SS SS SS SS SSSSSS SS SSX X X X X X X X X XXXXXXXXXELEC WWTTTTEEEEEEEETE TEEEEEEEEE E ETT T EEEEEEEEEEEEEEEEEEEEEEEE E EEEE EEEEEEEEEEEEEEETEXTENDED DETENTION BASIN REQUIRED VOL=35,357 CF PROVIDED VOL=37.005 CF CURB INLET STORM DRAIN POND OUTLET STORM SYSTEM W/ INLINE DRAINS PROPOSED SWALE PROPOSED SWALE PROPOSED SWALE STORM SYSTEM W/ INLINE DRAINS RAIN GARDEN OUTLET ECLIPSE LANE STREET B)QUASAR WAYPROPOSED CULVERT (IRRIGATION DITCH) PARCEL X WILLOW BROOK PARCEL W WILLOW BROOK PARCEL R WILLOW BROOK POUDRE R-1 SCHOOL DISTRICT PARCEL NO. 8604000904 CURB & GUTTER (TYP.)EX DRIPLINE CANOPY (AREA UNDEERNEATH TO REMAIN UNDISTURBED) UPPER DETENTION WALL TO BE RAISED TO MATCH EX GRADE AT DRIPLINE UPPER DETENTION WALL TO BE RAISED TO REDUCE SLOPE FROM ROAD TAPER TOP WALL TAPER TOP WALL EX DRIPLINE CANOPY (AREA UNDEERNEATH TO REMAIN UNDISTURBED) CURB INLET STORM SYSTEM W/ INLINE DRAINS STORM SYSTEM W/ INLINE DRAINS A.2 0.85 AC C.1 0.62 AC C.2 0.35 AC C.3 0.52 AC C.5 0.63 AC B.1 1.18 AC C.4 0.07 AC A.1 0.49 AC RAIN GARDEN B 6' DRAINAGE & UTILITY EASEMENT 6' DRAINAGE & UTILITY EASEMENT 6' DRAINAGE & UTILITY EASEMENT TRACT D DRAINAGE EASMENT RAIN GARDEN A TRACT C DRAINAGE EASEMENT TRACT B DRAINAGE EASMENT A B C FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION HYDROLOGY SUMMARY CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH LID SUMMARY EXTENDED DETENTION BASIN SUMMARY A 1.62 AC LEGEND: PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET ADESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 11 NOTES: 1.REFER TO THE FINAL DRAINAGE REPORT FOR WILLOW BROOK, JULY 27, 2001 BY TST, INC. CONSULTING ENGINEERS FOR ADDITIONAL INFORMATION. UDPROPOSED UNDERDRAIN BENCHMARK PROJECT DATUM: NAVD88 BENCHMARK #1: City of Fort Collins Benchmark 2-03 Location: South side Kechter Road approximately 0.6 miles west of Strauss Cabin Road on the east end of the south parapet wall of the bridge over the Dixon Canyon Lateral. Elevation= 4898.14 (NAVD88) BENCHMARK #2: City of Fort Collins Benchmark 13-13 Location: On the west side of Strauss Cabin Road, approximately 90-ft south of Kechter Road, on the northwest corner of a storm inlet. Elevation= 4887.05 (NAVD88) Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) for their vertical datums. If NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) = NAVD88 - 3.18' Basis of Bearings South line of the Southeast Quarter of Section 4-6-68 as bearing South 88°11'39" East. EXISTING NATURAL HABITAT BUFFER ZONE PROPOSED NATURAL HABITAT BUFFER ZONE EXISTING WETLAND SheetKECHTER TOWNHOMESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealedby a ProfessionalEngineer in the employ ofNorthern EngineeringServices, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 25 All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT DR1 DRAINAGE EXHIBIT26 DESIGN POINT SUMMARY