Loading...
HomeMy WebLinkAbout1984-087-06/05/1984-AMENDING RULES AND REGULATIONS FOR THE OPERATION OF MUNICIPAL CEMETERIES RESOLUTION 84- 87 OF THE COUNCIL OF THE CITY OF FORT COLLINS AMENDING RULES AND REGULATIONS FOR THE OPERATION OF MUNICIPAL CEMETERIES WHEREAS, in Resolution 84-61, the City Council amended the Rules and Regulations for the Operation of Municipal Cemeteries relating to burial receptacle requirements; and WHEREAS, it is in the public interest and advancement of the general welfare that certain portions of Section 4-i of the Rules and Regulations for the Operation of Municipal Cemeteries be amended. NOW, THEREFORE, BE IT RESOLVED BY THE COUNCIL OF THE CITY OF FORT COLLINS that the Rules and Regulations for the Operation of Municipal Cemeteries be, and the same hereby are, amended as follows: Section 1. Section 4-i (1) (b) and (c) are repealed and readopted as follows: 4-i . Burial Receptacle Requirements. (1) (b) Polyesterine Plastic or Fiberglass - Poly- esterine plastic or fiberglass burial receptacles shall be made of commercial grade resin. The plastic or resin must be a type recommended by the manufacturer for such use based upon the strength, impact, corrosion and life requirements . The manufacturer shall substantiate their recommendation from test data developed by the manufacturer, by the manufacturer' s experience in related environments and service requirements, or by 5 years experi- ence in the manufacturing of fiberglass or plastic burial receptacles with successful case histories of their use. Plastic or fiberglass resins shall not contain any fillers or extenders, except as required for viscosity control . Pigments , dyes and colorants shall not be used in an build-up. P• Reinforcing for fiberglass shall be a commercial grade of fiberglass having a coupling agent which will provide a suitable bond between the fiberglass reinforcement and the resin. Resin and reinforcing should be measured to ascertain proper rate and volume of material applied . The finished surface shall be clean , smooth and uninterrupted with no cracks, crazes , resin spills/runs , dry spots , foreign matter or concentration of air bubbles . No air bubbles or pits larger than 1/16" in diameter or 1/32" in depth are allowed. All sanded areas shall be resin coated and no exposed fiber rein- forcement shall be allwed. Upon approval of the Cemetery Superintendent , poly- esterine plastic and fiberglass receptacles may be used in double depth burials as well as single depth burials provided that if such receptacles are used in double depth burials , no concrete, steel or copper burial receptacles shall be placed in the upper burial space. (c) Steel - Steel burial receptacles shall be manufactured from steel sheeting . A minimum sheet thickness of 12 gauge shall be used in the manufacturing of steel burial receptacles. Galvanized coating, painting or other corrosion protection may be used, as well as increased metal thick- ness, to provide the durability required. Bent, cracked or damaged steel receptacles may not be accepted. Passed and adopted at a regular meeting of the Council of the City of Fort Collins held this 5th day of June, 1984. ,� / Mayor ATTEST: City -2-