Loading...
HomeMy WebLinkAbout033 - 03/22/2011 - AMENDING CHAPTER 5, ARTICLE IV OF THE CITY CODE FOR THE PURPOSE OF AMENDING THE 2009 INTERNATIONAL M ORDINANCE NO. 033, 2011 OF THE COUNCIL OF THE CITY OF FORT COLLINS AMENDING CHAPTER 5, ARTICLE IV OF THE CODE OF THE CITY OF FORT COLLINS FOR THE PURPOSE OF AMENDING THE 2009 INTERNATIONAL MECHANICAL CODE AS ADOPTED WHEREAS, the City Council has determined that it is the best interests of the health, safety and welfare of the City and its citizens to better align Fort Collins' built environment with community goals of improved indoor environmental quality, protection of the natural environment, reduced carbon emissions, reduced energy use and reduced water use, and; WHEREAS, City staff has conducted a significant public outreach program, working with three advisory committees comprised of representatives from the residential and commercial construction industries, housing industry, real estate and appraisal industries, construction recycling industry, specialized-trade contractors, and regional code officials; and WHEREAS, on February 2, 2011, the substance of the amendments was presented to the Electric Board, and the Electric Board recommended approval of the amendments; and WHEREAS, on February 3, 2011, the substance of the amendments was presented to the Affordable Housing Board, and the Affordable Housing Board recommended against approval of the amendments; and WHEREAS, on February 9, 2011,the substance of the amendments was presented to the Landmark Preservation Commission, and the Landmark Preservation'Commission recommended approval of the amendments; and WHEREAS, on February 16, 2011, the substance of the amendments was presented to the Economic Advisory Commission, and the Economic Advisory Commission recommended approval of the amendments; and WHEREAS, on February 16, 2011, the substance of the amendments was presented to the Natural Resources Advisory Board, and the Natural Resources Advisory Board recommended approval of the amendments; and WHEREAS, on February 17, 2011, the substance of the amendments was presented to the Water Board, and the Water Board considered water related elements and recommended approval of those amendments; and 1 WHEREAS, on February 24, 2011, the substance of the amendments was presented to the Building Review Board, and the Building Review Board recommended against approval of these amendments; and WHEREAS, on February 28, 2011, the substance of the amendments was presented to the Air Quality Advisory Board, and the Air Quality Advisory Board recommended approval of these amendments; and WHEREAS, based on the input obtained through this outreach process, together with City Council and advisory board review and comment, staff has developed proposed amendments to the 2009 International Mechanical Code ("IMC") as set forth in this Ordinance; and WHEREAS, the City Council has determined that it is in the best interests of the health, safety and welfare of the City and its citizens that the IMC as adopted be amended. NOW, THEREFORE, BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT COLLINS as follows: Section 1. That the opening paragraph of Section 5-107 of the Code of the City of Fort Collins is hereby amended to read as follows: Sec. 5-107 Amendments and deletions to code. The 20091nternational Mechanical Code adopted in § 5-106 is hereby amended in the following respects: Section 2. That Section 5-107 of the Code of the City of Fort Collins is hereby amended by the addition of a new subsection (6) which reads in its entirety as follows: "Section107.3 is hereby amended to read as follows: 107.3 Testing and verification. Mechanical systems shall be tested and performance verified as required in this code and in accordance with Section 107.3.1 through 107.3.3. Installed heating, cooling and ventilation systems shall be performance-tested by an approved agency and adjusted to operate within design specifications, in accordance with ANSI/ACCA QI 5-2007 HVAC Quality Installation Specification. Documentation of results shall be submitted to the Building Official prior to approval. Exception: Buildings subject to commissioning requirements in Section 3604.1 of the 2009 International Building Code as amended." Section 3. That Section 5-107 of the Code of the City of Fort Collins is hereby amended by the addition of a new subsection which reads in its entirety as follows: 2 Section 202 GENERAL DEFINITIONS, is hereby amended to add the following definitions in alphabetical sequence as follows: "MULTIFAMILY. Any building housing group R-1, R-2 or R-4 occupancies. Section 4. That Section 5-107 of the Code of the City of Fort Collins is hereby amended by the addition of a new subsection(9) which reads in its entirety as follows: (9) Section 407 is hereby added to read as follows: "SECTION 407 WHOLE-DWELLING UNIT VENTILATION. 407.1 Whole-dwelling unit ventilation. For new multifamily buildings, a mechanical exhaust system, supply system, or combination thereof shall be installed for each dwelling unit to provide whole-dwelling unit ventilation. Such system shall comply with Sections 407.1.1 through 407.1.5. 407.1.1 Whole-dwelling unit ventilation rate. The mechanical ventilation system shall provide outdoor air at no less than the rate specified in Table IRC M1507.4.1.1. TABLE 407.1.1.1 DWELLING UNIT VENTILATION AIR REQUIREMENTS, CFM' CONDITIONED NUMBER OF BEDROOMS FLOOR AREA 0-1 2-3 4-S 6-7 >7 (square feet) < 1,500 30 45 60 75 90 11501-3,000 45 60 75 90 105 3,001-4,500 60 75 90 105 120 4,501-6,000 75 90 105 120 135 6,001-7,500 90 105 120 135 150 >7,500 105 120 135 150 165 l.Equation M1507.4.1 can be used as an alternative to Table M1507.4.1.1 Equation M1507.4.1: Qfan = O.OlAfloo,+ 7.5(Nb,+ 1) Where: Qfan,= fan flow rate in cubic feet per minute (cfm). Afloor= conditioned floor area in square feet (ft). Nb,= number of bedrooms; not to be less than one. 407.1.2 System design. The design of the required whole dwelling unit ventilation system shall comply with the requirements of this Section. System 3 design documents shall be submitted, as required by the Building Official, at the time of application for a building permit. 407.1.2.1 System type. The system shall consist of one or more supply or exhaust fans, or a combination thereof, and associated ducts and controls. Exhaust fans shall be permitted to be part of a mechanical exhaust system. Outdoor air ducts connected to the return duct of a forced air furnace shall be sized to provide adequate mechanical ventilation in accordance with ASHRAE 62.2 and shall meet the manufacturer's requirements for minimum return air temperature to the furnace heat exchange. 407.1.2.2 Outdoor air intakes. Outdoor air intakes shall have automatic dampers that close when the ventilation system is not operating. 407.1.2.3. Exhausts. Exhausts shall have gravity dampers that close when the ventilation system is not operating. 407.1.2.4 Air circulation fan motors. Motors for air circulation fans used in the ventilation system, rated at one-quarter horsepower or greater, shall meet at least one of the following criteria: 1. Where the furnace serves as an air handler for the ventilation system, the furnace shall be certified as an "Electrically Efficient Furnace" by the Air-conditioning, Heating and Refrigeration Institute (AHRI). 2. The blower motor shall be specified as a "Brushless DC" (BL or BLDC) motor by the manufacturer. 3. The blower motor shall be specified as "Brushless Permanent Magnet" (BPM) motor. 4. The blower motor shall be specified as "Electronically Commutated Motor(ECM)". 5. The blower shall meet equivalent criteria acceptable to the Building Official. 407.1.2.5 System controls. The mechanical ventilation system shall be provided with readily accessible and labeled controls that enable occupant override. 407.1.2.6 Sound ratings for fans. Whole-building ventilation fans shall be rated for sound at a maximum of 1.0 sones, in accordance with the procedures of the Home Ventilating. Institute (HVI 915, Procedure.for Loudness Rating of Residential Fan Products). Exception: Heating, ventilating and air conditioning air handlers and remote-mounted fans need not meet sound requirements. To be considered for this exception, a remote-mounted fan must be mounted 4 outside the habitable spaces, bathrooms, toilets and hallways, and there must be at least 4 ft (1 m) of ductwork between the fan and the intake grille. 407.1.3 System installation. The installation of the whole-dwelling unit ventilation system and equipment shall be carried out in accordance with the manufacturers' design requirements and installation instructions. 407.1.4 Performance verification. Performance of installed mechanical ventilation systems shall be verified in accordance with Section 107.3." 407.1.5 Dwelling unit isolation. All doors between dwelling units and common hallways shall be gasketed or otherwise substantially airtight with weather stripping, except when the ventilation system explicitly requires transfer air from corridors into units." Section 5. That Section 5-107 of the Code of the City of Fort Collins is hereby amended by renumbering subsections 8 through 17 accordingly. ' Section 6. That the requirements will be effective as to all applications for building permits filed on or after January 1, 2012. Introduced, considered favorably on first reading, and orddd published this 1st day of ' March, A.D. 2011, and to be presented for final passage on the 2-2nd day o March, A.D. 11. Mayo ATTEST: City Clerk " Passed and adopted on final reading on the 224day ch, A.D. 2011. ATTEST: City Clerk 5