HomeMy WebLinkAbout006 - 03/13/1916 - CREATING AN ELECTRICAL INSPECTION DEPARTMENT FOR THE GENERAL INSPECTION AND REGULATION OF ELECTRICAL �Y ORDINANCE NO i1916 AN ORDINANCE CREATING AN ELECTRICAL IISPECTION DEPARTIMT FOR THE GENERAL INSPECTION AND REGULATION OF ELECTRICAL IN- STALLATIONS AND EQUIPTIENT WITHIN THE CITY OF FORT COLLINS AND PROVIDING PENALTIES FOR VIOLATION THEREOF BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF FORT COLLINS Section 1 That there is hereby created and established a department of city government to be known as the DLPARTEEITT OP ELECTRICITY said department to be in charge of the Commissioner of Safety Section 2 The Commissioner of Safety is hereby authorized empowered and directed to have general supervision over the arranging supporting and stringing of all electric light power telephone signal or otherwise and locating and general inspection of all poles lines and electrical appliances so as to prevent fires accidents or injuries to persons or property further it shall be the duty of the Commissioner of Safety to cause all such lines and equipment to be maintained and guarded so as not to endanger life or property and all such lines and equipment now existing aG well as those hereafter constructed and installed shall be subject to such supervision Section 3 The Commissioner of Safety is hereby authorized and empowered upon the approval of the Citj Council to appoint a deputy Electrical Inspector vhose duties shall be as provided in this ordinance and to receive such compensation as may be provided by the City Council It shall be the duty of the Commissioner of Safety or the Deputj Electrical Inspector to c ) make a thorough inspection of the outside lines of all com- panies o-vning wires in the city at least once in each year where such lines are in dangerous condition the Commissioner of Safety or the deputy inspector shall notify the company or person owning using or operating them to place them in a safe and secure condition fortlwith Any company or person failing or refusing within fort-17--eight (48) hours after such notice to begin necessary repairs or changes and have the said work completed within ten (10) days after the receipt of such notice shall upon conviction be subject to a penalty of Ten Dollars for each day until the Tires are repaired or changed as directed by the Commissioner of Safety or his. deputy Section 4 The Commissioner of Safety shall be deemed the sole ,judge as to the proper interpretation of the rules and regulations of this ordinance pertaining to the electrical inspection and is hereby authorized and empowered to make such additional rules and regulations as may be deemed necessary for the proper carrying out of the provisions of this ordinance Any such additional rules and regulations as shall be made by him shall be made in writing and duly printed and filed with the City Clerk of the City of Fort Collins and a copy thereof shall be duly furnished to all licensed electrical contractors in the city of Fort Collins and all persons and corporations desiring the same Provided that said Commissioner of Safety shall not make any rales or regulations that in any way modify or change the provisions of this ordinance Section 5 Every company firm co-partnership crrpora- tion or individual owning or controlling electrical wires and -2- c � 1 apparatus for the transmission of light heat or pourer shall in time of fire or case of severe storm wherein lives or property of the citizens of the City of Fort Collins may be endangered by the operation of such wires and apparatus upon the request of the Commissioner of Safety Commissioner of Public Works or the captain of the fire department disconnect; such wires as are designated by suer officials such company firm corporation or individual refusing and neglecting to com-oly with such request shall be subject to a fine of not less than Fifty Dollars nor mnre than One Hundred Dollars for each and every hour said request is not complied with Section 6 It shall be the duty of the Commissioner of Safety or his deputy to inspect all electrical wiring and apparatus in the City of Fort Collins when ordered by the City Council in order to ascertain whether such electrical wiring or apparatus is in anj respect dangerous to life or property and if any part of said electrical wiring or appar- atus shall be found to be in a defective or dangerous condition the Commissioner of Safety or his deputy shall notify in writing the owner of such wiring or equipment to rave buch defects corrected within such time as the Commissioner of Safety or his deputy may deem necessary If the owner of said defec- tive wiring or equipment shall refuse br fail to comply with the requirements of the Commissioner of Safety or his deputy- and correct all defects as directed within the specified time it shall be the duty of the Comnissioner of Safety or his deputy to notify the service company firm or inaividual furnishing the electric current to such defective wiring or equipment to cease to supply electric current to the same and upon the receipt of such notice the service company firm or individual furnishing electric current to such defective wiring or -3- l � equipment shall immediately disconnect the service or feed wires as directed by the Commissioner of Safety or his deputy and cease to supply current to tre defective instal- lation until notified in writing by the Commissioner of Safety that the defects have been corrected in a satisfactory manner Section 7 All companies firms corporations or individuals engaged in the business of installing electrical wires or appliances inside of or on antr building or ouildings within the corporate limits of the City of Fort Collins exce»t central stations power houses substation or car barns for the purpose of transmitting or utilizing the electrical current for light heat or power house annunciators burglar alarms electric bells electric signal systems private telephone telegraph or messenger call system lighting fixtures or installing electrical apparatus of any nature kind or description shall upon form of application to be prescribed by the Commissioner of Safety apply to the City Council for a license which application shall be accompanied by a good and sufficient bond in the sum of One Thousand Dollars con- ditioned that all electric work installed by said company firm corporation its emplojes or individual shall be in accordance with the requirements of this ordinauice and if such license shall be granted said company firm corporation or individual shall cause to be paid to the City Clerk the sum of Twenty-five Dollars in advance as the annual fee for such license and upon tha presentation of a receipt for said fee to the Commissioner of Safety or his deputy said license shall be duly issued to the corporation or person entitled thereto Section 8 The following fees shall be charged and col- lected by the Commissioner of Safety or his deputy for inspection -4- t ) services as follo*vs For roughing in" of concealed wiring or for open wiring first five outlets or fraction thereof fifty cents (50�) each adaitional outlet five cents (5¢) For installing conduit first five outlets or fraction thereof fifty cents (50¢) each additional outlet five cents (51) For installing fixtures fans arc lamps drop lights or switches on concealed or conduit wiring for the first five or fraction thereof fifty cents M ) each additional fixture fan are lamp drop light or switch five cents (5h) ITO charge to be made for switch when located in approved cabinets For signs one dollar (�l 00) each r.�F�or each electric stove or neater For motors and generators one-fourth to three-horse power one dollar (�l 00) over three-horse power to five-horse power One dollar and fifty cents (�l 50) each over five-horse noier two dollars (V2 00) each For addition to old work for one outlet, twenty-five cents (25¢) two outlets fifty cents ( 50�) for more than two and not more than five one dollar (q�l 00) in excess of five ten cents (10�) for each outlet The term "outlet" in this ckause is intended to mean either the outlet fixture or both when installed at the same time and only requires one inspection If for any reason after a permit has been issued as herein provided it is necessary to construct additional outlets a fee of fifty cents ( 50�) shall be charged for the firs' five additional outlets or fraction thereof and five cents ( 5¢) for each additional outlet not included In the permit and a new permit must be taKen out to cover the same For inspection of apparatus or reinspection made necessary because of defects in work for which no fee is herein nrescrioed -5- the insroector shall charge one dollar Uil 00) for the first hour or part thereof and one dollar (�l 00) for each additional full hour engaged in making the inspection When any addition or change is made to work for which a certificate has been issued and where a permit was not issued for the addition the original certificate shall he cancelled and the regular fee charged for reinspection of the original and additional work, which fee shall be paid to the City Clerk before a new certificate can be issued for the entire instal- lation Section 9 Any person firm or corporation engaged in the business of electrical construction and the installation of wiring or apparatus for electric light heat or power in the City of Fort Collins wY o shall fail to promptly correct any defect or defects in his or their work after having been duly notified in writing by the Commissioner of Safety or his deputy shall not be entitled to receive any further permit until such defect or defects have been corrected and any case in which anj person shall continue to or persistently violate the ordinance of the city in regard to electrical affairs or the orders of the Commissioner of Safety or his deputy respecting the same the City Council upon proper showing to that effect snall revoke such license Section 10 All companies firms co-partnerships corporations or individuals licensed to do electric wiring in or on any building or buildings within the corporate limits of the City of Fort Collins shall procure a wiring permit from the Commissioner of Safety or his deputy but in order to procure such permit shall exhibit to the Commissioner of -6- Y � Safety or his deputy a receipt showing that tbp fees required for the issuance of said permit have been duly paid to said clerk The term "electric wiring" herein used is intended to mean the installation of electric wires fixtures appliances or apparatus used or to be used for the purpose of transmitting regulating controlling or utilizing electric current for light heat or power No permit shall he issued except to persons or corporations having a license as provided in this ordinance and no work shall be done prior to the issuance of the permit herein provided which said permit shall be duly issued after payment of the fees upon application duly filed with the Com- missioner of Safety or his deputy the form of which application shall be prescribed by the Commissioner of Safety Section 11 Where from good and sufficient causes properly presented and shown to the Commissioner of Safety or his deputy it becomes necessary to have electricity on any installation before final certificate can be issued the Commissioner of Safety or his deputy may issue a temporary permit provided that all parts to which current is applied are in a safe and satisfactory condition to said Commissioner of Safety or his deputy, said permits to expire in thirty days If at the end of thirty days the installation is still incomplete another permit may be issued for the next thirty days and for each succeeding thirty days until said work is completed and accepted Provided such temporary permit shall not cover a total period of more than ninety days Section 12 It shall be unlamful for any owners con- tractors or workmen to in any manner interfere with any electric wiring in or on any building in any manner whatsoever If in any case the wiring is in such position as to interfere with the completion of the building as called for by the pla.nd and -7- } specifications the wiring contractor must be notified to have it changed No wood or metal work is to be placed within one inch of any unprotected electrical conductor On inspecting the electric wiring of any building the Com- missioner of Safety or his deputy shall leave a written or printed notice in the form of a tag or label attached to or near the service cabinet This notice shall clearly state wl^ether the wiring is approved or is to be kept open for cor- rection and no workman shall lathe veil or in any manner conceal any electric wiring until he knors positively that it has been approved The Commissioner of Safety or his deputy shall in all cases inspect any electric viring within the corporate limits of the City of Fort Collins within forty-eight hours of the receipt of written notice from the electric wiring contractor that the work is completed holidays and Sundays not included in this time All steam fitting furnace work gas fitting and telephone wiring which is to be concealed must be installed before the electric wiring is completed and no wiring will be considered as complete until the above work referred to is in place Section 13 On the completion of the wor.E covered by the hermit in accordance with the provisionsof this ordinance and to the satisfaction of the Commissioner of Safe% or his deputy said Commissioner of Safety or his deputy shall issue a certificate which shall certify that the work is in accordance with the provisions of this ordinance and the rules established respecting said matters and to the class to which it belongs Whenever agy permit is issued for an addition to the old work which does not conform to the requirements of this ordinance and upon the satisfactory completion of the addition the -8- additional certificate shall be issued by the Commissioner of Safety or his deputy which said certificate shall state that the new work complies with the provisions of the ordinance but a final certificate cannot be issued owing to its connection with old work which does not comply with this ordinance Section 14 No alteration or change shall be made in the electric wiring of any building nor shall any building be wired for lights motors or heating devices or any other electrical apparatus of whatever character, nor shall any electrical apparatus be installed without first paying to the City Clerk the fees provided in Section 8 of this ordinance and thereafter presenting the receipt secured from the City Clerk to the Commissioner of Safety or his deputy for the issuance of a permit whereby said alterations or installations can he installed Mien any alterations or changes are made in the wiring of any building or any new wires or electric apparatus are installed it shall be the duty of the company firm corporation or individual doing or having such work done to notify in writing the Commissioner of Safety or the: deputy electrical inspector immediately after the completion of said work that the worK is ready to inspect On business blocks hotels apartment houses an inspection will be made of different sections of the work at the discretion of the inspection department in order not to delay the other work in connection with the construction of the building Proper conveniences such as ladders must be provided the inspector by the firm corporation or individual desiring inspection Permits issued under this section shall be upon forms prescribed by the Commissioner of Safety or the Deputy Electrical Inspector and all forms required for the purpose of operating the Electrical Inspection Department shall be prepared and provided by the Commissioner of Safety or the Deputy Electrical Inspector -9- 1 f Section 15 It shall be unlawful for any electric service company to make connection to any electrical installation or supply current to same until the certificate of approval has been issued by the Commissioner of Safety or his deputy Provided that if at any time any electrical installation or any portion of the same is found by the electrical inspector to be in an unsafe or defective condition the electric service company stall upon written notice from the Commissioner of Safety or his deputy disconnect from such installation or portion thereof as directed by said Commissioner of Safety or his deputy and cease to furnish electric current to the same until permission for re-connection in writing is granted by the Commissioner of Safety or his deputy When the service has been disconnected on any electrical installation or part of same for any reason whatsoever and such wiring or apparatus ap»ears to be in a dangerous or defective condition the service company shall not be required to again connect or supply current for the same until notified by the Commissioner of Safety or his deputy that the installation is in a safe and secure condition \� Section 16 The electrical contractor applying for a wiring permit shall be required to furnish such plans and specifi- cations for proposed work as may be deemed necessary by the Commissioner of Safety or his deputy before any permit for the same shall he issued Section 17 All electric wiring hereafter installed including additions extensions or changes to existing wiring used for transmission of current for light heat or power in or on all buildings located within the fire limits of the City of Fort Collins shall be installed in approved steel conduits or metal mouldings All electric services hereafter installed -10- } / 6 for brildings located either within or outside the fire limits and within the corporate limits of the City of Fort Collins shall be in approved steel conduit equipped at outer end with an approved service or condulet fitting and run continuously without outlet or ,unction bog into a service cabinet of approved steel construction with Underwriters label of approval attached thereto said cabinet shall be located inside the walls of building in the nearest accessible places to the rooxnt where the wires enter building but in no case over fifteen (15) feet from the point of entrance The cabinets shall be so arranged that the handle of service sw_tch located therein shall not be over seven (7) feet above a permanent floor The cabinet and conduit to be securely bonded and grounded but in no case shall the conduit system be used to ground secondary system Conductors for all underground services and all con- ductors it or beneath basement floors will be considered as subject to moisture and must be lead-sheathed Section 18 All meter loops shall be run in steel conduit and equipped with aronroved outlet boxes or condulet fittings with covers arranged with separate porcelain bushed holes for each wire Where service type cabinets are used and meters located in close p raximity to same meter-loops may be run directly from cabinet to meter each wire to be run separately through side of cabinet and protected with approvea porcelain bushings designed for such purpose Section 19 For general lighting inside builaings with concealed conduit or knob and tube work not over eight (8) light outlets will be permitted on any one circuit and with exposed conduit or metal moulding cork not over eleven (11) outlets will be permitted on any one circuit Each and every lamp socket or receptacle v7111 be assumed as using not less than -11. a sixty (60) watt lamp and there shall not be over eleven (11) socYets or receptacles on any one circuit excepting as where permitted under special rules Section 20 For all electric mator installations the capacity of conductors shall not be less and the size of fuses shall not be greater than provided for in the following tables Services and mains for alternating current systems feeding a IV group of tao or more motors must have a safe carrying capacity,-- Twenty-five per cent in excess of the total normal rating of all motors attached thereto but in no case less than specified for the largest motor of the group which said table is as follows being Rule 18 of Table A Rational Electrical Code ALLWABLE CAI'RYING CAPACITIES OF SIRES Table A Table B B & S. Diameter of Area in Rubber Other Gage TTo Solid Wire Circular Insulation Insulation in Mils Hils Amperes Amperes 18 40 3 1 624 3 5 16 50 8 2 583 6 10 14 64 1 4 107 15 20 12 80 9 6 530 20 25 10 101 9 10 380 25 30 8 128 5 16 510 35 50 6 162 0 26 250 50 70 5 181 9 33 100 55 80 4 204 3 41 740 70 90 3 229 4 52 630 80 100 2 257 6 66 370 90 125 1 289 3 83 690 100 150 0 325 105 500 125 200 00 364 8 133 100 150 225 0000 409 6 167 800 175 275 200 000 200 300 0000 460 211 600 225 325 300 000 275 400 400 000 325 500 5009000 400 000 600 OOC 0 450 680 700 000 500 760 800 000 550 840 900 000 600 920 1 000 000 650 1 000 1 100 000 690 1 080 1 200 000 730 1 150 1 3000000 770 1 220 1 400 000 810 1. 290 1 5000000 850 1 360 1 600 000 890 1 430 1 -fil = 0 001 inch 1 700 000 930 1 490 1 800 000 970 11 550 2 00 000 1 050 1 G70 All electric motors shall be installed and maintained in strict accordance with the tables rules and requirements as provided in Electfical Bulletin No 2 issued by the Rocky Y ountain Fire Underwriters under date January 1914 as follows to-tint SINGLE PHASE Alternating Current Motors 110 Volts Current Ika.43.m17m Ma.&Imum Size Rating Size Wire Starting Running P Amperes B Ec 3 Gauge Fuse 1 use 5 6 6 12 25 15 1 14 8 40 25 2 24 6 70 40 3 32 4 90 50 5 52 1 150 75 7 5 80 0 200 100 10 100 000 250 125 15 140 300 000 C Id 350 175 20 192 400 000 C Ij 475 250 25 216 500 000 C 2 550 275 30 280 600 000 Q TA * 350 35 310 700 000 C 7d * 400 50 440 1 100 000 C Id * 550 * Automatic overload circuit breaker required SINGLE PHASE Alternating Current motors 220 Volts Current Liam-,mum Idaximmm Size Rating Size Aire Starting Running H P ATnperes B & o Gauge Fuse Fuse 5 3 3 14 15 10 1 7 12 25 15 2 12 8 40 20 3 16 8 50 25 5 26 5 80 40 7 5 40 3 100 50 10 50 2 125 60 15 70 0 175 90 20 96 00 225 125 25 108 000 275 150 30 140 0 000 325 175 35 155 300 000 C M 400 200 50 220 400 000 C ICI 500 275 -13- I ► THREE PHASE Alternating Current Motors 220 Volts Current Maximum riapimum Size Rating Size Wire Starting Running H P Amperes B & S G-auge F-L_se Fuse 5 2 14 10 5 1 3 7 14 15 10 2 6 6 14 20 15 3 9 3 10 30 20 5 15 8 50 30 7 5 22 6 60 35 10 29 4 75 40 15 41 2 110 60 20 55 1 150 75 25 62 0 175 90 30 81 0 200 100 35 92 00 225 125 50 127 0 000 325 175 75 192 400 000 C M 500 250 100 248 500 000 C I4 600 325 150 366 700 000 C M * 475 200 475 900 000 C Id * 600 THREE PHASE Alternating Current Motors 440 Volts Current Maximum Maximum Size Rating Size 171re Starting Running H P Amperes B a S Cauge Fuse Fuse 1 1 8 14 5 3 2 3 3 14 10 6 3 4 7 14 15 10 5 7 5 12 25 15 7 5 11 10 30 15 10 14 8 40 20 15 20 8 50 25 20 27 6 70 35 25 31 4 80 40 30 40 2 100 50 35 46 2 125 60 50 64 0 160 80 75 96 00 225 125 100 124 000 275 175 150 183 300 000 C d 375 225 200 237 400 000 C M * 300 * Automatic overload circuit breaker required —14— w ► THREE PHASE Alternating Current Iotors 2200 Volts Current Circuit Breakers Size Rating Size Tire Adjusted for H P Amperes B & S Gauge Amperes* 15 4 12 6 20 6 12 8 25 7 12 10 35 10 10 13 50 14 8 18 75 21 6 27 100 27 4 35 150 41 2 53 200 54 0 70 *Motors equipped with only automatic circuit breaker protection with adjustment as per table to protect motors should have breakers equipped vith special inverse time limit element designed and adjusted to, operate in approximately one-half minute with a load of 200 per cent of the calibration setting of the breakers to take care of the b igh starting current TCIO PHASE Alternating Current i+iotors 220 volts Current Maximum ivlaximum S1Ze Rating. Size Wire Starting Running F P Amperes B & S Gauge Buse Fuse 1 3 14 10 5 2 5 14 15 10 3 7 5 12 25 15 5 13 8 40 20 7 5 20 8 50 25 10 25 6 70 35 15 35 4 90 50 20 48 2 125 60 25 54 1 150 75 30 70 0 175 90 35 82 0 200 100 50 110 000 275 150 75 165 300 000 C wI 400 200 100 215 400 000 C 1 450 275 150 320 600 000 C Id * 400 200 410 800 000 C M * 500 *Automatic overload circuit breaker required -15- M i TWO LuASE Alternating Current rlotors 440 Volts Current R Maximum Maximum Size Hating Size hires Starting Running H P Amperes B & S Gauge Fuse Fuse 1 1 5 14 6 3 2 2 6 14 8 5 3 3 8 14 15 8 5 6 5 14 20 15 7 5 10 12 25 15 10 12 5 10 30 20 15 18 8 50 25 20 24 6 60 30 25 27 6 70 35 30 35 4 90 50 35 41 2 110 60 50 55 1 150 75 75 83 0 200 100 100 108 00 225 150 150 160 0 000 325 200 200 205 300 000 C id 400 250 DIRECT CURRENT MOTORS 110 Volts CURRLN Size Rating Size Wire Idaximum H P Amperes B & S Gauge Size Fuse 5 5 14 10 1 9 12 15 2 17 10 25 3 26 6 35 5 40 6 50 7 5 60 3 75 10 76 1 100 15 112 00 150 20 150 200 000 C J 200 25 190 300 000 C M 250 30 226 400 000 C M 300 40 300 500 000 C 1 375 50 368 600 000 C I 450 75 550 1 100 000 C M 100 736 1 700 000 C ICY *Automatic overload circuit breaker required -16- r � DIRECT CURRENT MOTORS 220 to 250 Volts Bur re nt Siee H P Rating Size Wire Idiaximum Amperes B & S Gauge Size Fuse 5 2 5 14 5 1 4 5 14 10 2 8 5 14 15 3 13 12 20 5 20 10 25 7 5 30 6 40 10 38 6 50 15 56 4 70 20 75 1 100 25 95 0 125 30 113 00 150 40 150 200 000 C t: 200 50 184 300 000 C 1A 250 75 275 500 000 C M 350 100 368 600 000 C m 450 DIRECT CURRENT L OTORS 500 to 550 Volts Current Size F P Rating Size Wire Maximum Amperes B & S Gauge Size Fuse 5 1 14 3 1 2 14 5 2 3 7 14 8 3 5 6 14 10 5 8 a 14 15 7 5 13 12 20 10 17 10 25 15 25 8 35 20 33 6 40 25 42 6 50 30 50 4 60 40 66 2 80 50 81 1 100 75 122 00 150 100 162 200 000 C M 200 150 244 400 000 C M 300 200 324 500 000 C M 400 T17— Section 211 It shall be unlawful for any company firm corporation co--partnership or individual to construct use or permit to be used within the fire limits of the City of Fort Collins any lines for the transmission of electric current for light heat or power with a potential in excess of five thousand (5 000) volts Provided that all such lines now existing or hereafter erected or placed along any alle„ or street outside of said fire 1 imi is and within the corporate limits of the City of Fort Collins with a potential in excess of five thousand volts shall be placed in approved underground ducts or upon substantial poles of sufficient height to maintain such lines at least three (3) feet above all other lower potential lines and shall be constructed maintained and guarded in accordance with the rules and requirements adopted by this ordinance Section 22 All electrical construction all material 4 is� and all appliances used in connection with electrical work and the operation and arrangenert of all electrical apparatus shall be in conformity with the rules and regulations published in what is known as the "TTational Electrical Code of 1915 " which said rules and regulations are hereby approved and adopted as a part of this ordinance Section 23 The Commissioner of Safety or his deputy inspector shall have the tight to enter upon any premises at all reasonable hours for the purpose of inspecting the same Section 24 This ordinance shell not be construed to relieve from or lessen the responsibility or liability of any person owning operating or installing any electrical tires appliances apparatus construction or equipment from damages to person or property due to any defect therein nor shall the -18- � F City of Fort Collins or any agent thereof be held as assuming any liability by reason of the inspection authorized herein or in the certificate of inspection issuea by the Commissioner of Safety or his deputy Section 25 Any person or corporation who shall violate any of the urovisions of this ordinance for which a penalty is not herein otherwise provided and any occupant or oviner of premises wYere electric % firing or apparatus is used or to be used who shall refuse to allow or shall prevent or interfere with the Commissioner of Safety or his deputy inspector in the discharge of their duties under this ordinance he or they shall upon conviction for each offense forfeit and pay a fine of not less than ten dollars (�10 00)a nor more than one hundred dollars (9100 00) and each and every day' s continuance of any violation of the rorovisions of this ordinance shall constitute and be deemed a separate offense Section 26 All ordinances or parts of ordinances of the City of Fort Collins in conflict herewith are hereby repealed �,o0 r, - VY� Passea and adopted this ,�h. day of Fe4_u� A D 1916 mmissioner of Safety an Ex-Officio Mayor ATTEST 2_tg�6 CCAb --� dity Clerk � r STATE OF COLORADO } ss COUNTY OF DARIiIER I I Ray Baxter City Clerk of the CitS of Fort Collins do hereby certify and declare that the foregoing ordinance consisting of 215 sections duly proposed and read at length at a meeting of the City Council held on the day of February A D 1916 was duly ordered by "Aye' and "Nay" vote to be published in the Fort Collins Express a daily newspaper of the City of Fort Collins in accordance with the provisions of Section 7 of Article IV of the City Charter that thereafter and on to-wit the 1t�-', 15 day of xy 1916 at a regular meeting of the City Council 9-tid ordinance came before said Council on its final passage a period of more than ten days having elapsed since the publication as above set forth and that said ordinance was upon second reading ,padopted as an ordinance and thereafter and on to-vast the 1 �tK. day of ' I 04� 1916 said Ordinance Teo L, as finally massed and adopted vas duly published in the Fort Collins Express a daily newspaper published in the City of Fort Collins Colorado In Witness Whereof have hereunto set my hand this S�day of 1I` 1916 U / Cit T Clerk APPROVED Mayor