Loading...
HomeMy WebLinkAbout124 - 10/16/1979 - AMENDING SECTION 3302 OF THE UNFORM BUILDING CODE INSOFAR AS IT RELATES TO REQUIRED EXITS 4 OPDINANCE NO 124 , 1979 BEING AN ORDINANCE MENDINC SECTION 3302 OF'THE UNIFORM BUILDING CODE INSOFAR AS IT RELATES TO REQUIRED EXITS BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT COLLINS as follows Section 1 That Section 3302 (a) of the Uriform Building Code, 1976 Edition, be, ano the same hereby is, amendea to rear as follows "§3302 (a) Number of Exits Every building or usable portion thereof snall have at least one exit, and shall have not less than two exits where required by Table No 33-A In all occupancces, floors above the first story having occupant load of more than ten shall have not less than two exits Each mezzanine useo for other than storage purposes, if greater in area than 2,000 square feet, or if more than 60 feet in any dimension shall have not less than two stairways to an adjacent floor For a special requirement for Groups A, E , I , and H Occupancies, and oper parking garages, see Sections 3315, 3316, 3317, 3318, 3319, and 1109 (g) For stage exits, see Section 3907 Every story or portion thereof having an occupanct load of 500 to 999 shall not have less than three exits Every story or portion thereof, having an occupant load of 1 ,000 or more shall have not less than four exits The numDer of exits required from any story of a building shall be deierrrined uv usire the occupant load of that story , plus the percentages of occupant load of floorage which exits through the level under consideration as follows 1) Fifty percent (50/) of the occupant load in the first adjacent story above (and the first adjacent story below, when the story below exits through the level under consiaeratior) 2) Twenty-tive percent (25%) of the occupant load in the ,tort' iw wdi atel , OFjond the 'irsu an.1aue9t story The i, aximum number of exits requirea for any story shall be raintained until egress is provided from the structure (See Section 3311 ) For the purposes of tnis Section , basements or cellars ana occupied roofs shall oe provided %vith exits as reouirec, for storage Floors above the second story, basements anu cellars used for other than tna service of the building shill not have less than two exits EXCEPTIO41 1 ) Except as provided in Table ho 33-A, only one exit shall be equired rcr a nasenent or cellar of a Croup K , bivision 3 Occupancy - See Secticrr 14u4 for erreraency exits fiem sleeping rooms 2) An egi ess, rescue vnnoo,j meetinc the reautrements of Section 1304 may serve as one exit from a basement or cellar of a Group P, Division I arartment occupancy provided the folloti,mng conditions exist a The individual basement cr ea does not comprise a separate djelling unit b The incividual trsement area does not exceed /50 square feet or floor ar ee c The bese,ent or cellar exits are placed a dis- tance apart eoudl to and not less than one-half of the length of the maximum overall diagonal dimension of the area to be served measured in a straight line betveen exits d A products of combustion detector is located at the borerent stairudy e Basement areas of individual djelling units are seperated by one-hcur fire resistive de m sinq galls IntroarlCPd, considerca favorably on first reading, and orderea pub- lishen this 2nd day of October , A 0 1y79, and to ne presented for final nassaie or the 16th clay or Octob 197g J WCe CI y -2- Passed and cdorted ot, final icadiic this 16th dey October , h O 1979 i A T / Ci y Clerk -3-