HomeMy WebLinkAbout125 - 10/16/1979 - AMENDING SECTION 3802 OF THE UNFORM BUILDING CODE INSOFAR AS IT RELATES TO AUTOMATIC FIRE EXTINGUISH ORUINMICE 110 125 , 1979 BEING AN ORDINAvCE ANENDINC SECTION 38u2 OF THE UNIFORM BUILDING CODE INSOFAR AS IT RELATES TO AUTOMATIC FIRE EXTINGUISHING SYSTEM BE IT trRDAI.,'FU BY ThE COUNCIL OF THE CITY OF FORT COLLINS as follows Section 1 That Section 3302 (b) (1 ) of the Uniform Building Code, 1976 Edition, be, and the same hereby is, amenaed to read as follows "§3802 (b) Where Reauired ( 1 ) In every story, basement or cellar of all buildinas except Groups R, Division 3 and M occupancies where floor area exceeds 1500 square feet and there is not provided at least 20 square feet of opening entirely above the adjoininq ground level in each 50 lineal feet or fraction thereof of exterior wall in the story, Dasement or cellar on at least one side of the ouIluing Openings shall have the minimum aimension of not less tnan 30 inches Such openings shall be maintained readily accessible to the fire departrr.nt and shall not be obstructed in a manner that fire fighting or rescue cannot be accomplished from the exterior EXCEPTION An automatic fire extinguishing system shall not be requirea in a Group R, Division I aoartm erit , basement or cellar provided the following conditions exist a The individual basement area does not comprise a separate dwelling unit b The > >dividual basement area does not exceed 750 square feet of floor area c The basement or cellar exits are placed a dis- tance apart eaual to not less than one-half of the length of the maximum overall diagonal dimprision of the area to be served measured in a straight line between exits d A prcoucts of combustion detector is located at the oasernent of the stairway e Basement areas of individual dwelling units are separated by one-hour fire-resistive demising Jalls Then openings in a story are provided on only one side and the opposite wall of such story is more than 75 feet fron such openings , the story shall De provided with an approved automatic fire extinguishing system, or openings as specified above shall be provided on at least t<%o sides of the exterior galls of the story If any porticn of a basement or cellar is located more than 75 feet from opEninds required in this section, the baseneiit or cellar shall be provided with an approved autorratic fire extinguishinq system " Introduced , considered favorably on first reading, and ordered pub- lished this 2nd day of October , A D 1979, and to be preserted for final passage on the 16th day of October A D 1979 Vayor EST "y C e r Passed and adopted on final reading this 16th day of October , A D 1979 Pia ST tify 0 er k -2-