Loading...
HomeMy WebLinkAbout129 - 10/16/1979 - AMENDING SECTION 2517 OF THE UNIFORM BUILDING CODE INSOFAR AS IT RELATES TO FOUNDATION VENTILATION ORDINANCE NO 129 , 1979 BEING AN OPDINA110E APPENDING SECTIOri 2517 OF THE UNIFORM BUILDING CODE INSOFAu AS IT RELATES TO FOUNDATION VENTILATION FE IT ORLAINED BY THE COUVCIL OF THE CITY OF FORT COLLINS as follows Section 1 That Section 2517 (c) (6) of the Uniform Building Code, 1976 Eaition be, and it the same hereby IS, anienaea to read as follows "§2517 (c) (6) Foundation ventilation Underfloor areas shall be ventilated Ly an approved mechanical means or by openings in exterior foundation walls Sucn openings shall have a net area of not less Van 1-1/2 square feet fo, each 25 linear feet of exterior wall Openings shall be locatea as close to corners as practicable and shall provide cross ventilation on at least two approximately opposite sides They shall be covered with corrosion resistant wire mesh not less than 1/4 inch nor more than 1/2 inch in any dimension As an alternate to the required fol�ndation openings or mechanical ventilation system, a ground cover consisting of a mnninum 6 mils thick plastic with a minirium six inch lap at all ,joints may be substi- tutea Where extreme moisture problems are en- countered, the Fuiloinq Official may require a four inch cranular Linder I ayment and ventilation as deemed necessary " Introduced , considered favorauly on tirst reading, ann ordered published this 2nd day of October , A D 1579, and to be presented for final passage on the 16th day of October D 1979 7 A S1 Ci y er x Passed and adopted on final reading this 16th_ day of October , A D 1979 �'aT 0 r 1z)e Z-f H T City' lerk -2-