Loading...
HomeMy WebLinkAbout175 - 01/06/1981 - AMENDING CERTAIN SECTIONS OF THE UNIFORM BUILDING CODE, 1979 EDITION ORDINANCE NO 175 , 1980 OF THE COUNCIL OF THE LIP—OF FORT COLLINS BEING AN ORDINANCE AMENDING CERTAIN SECTIONS OF THE UNIFOPM BUILDING, CODE, 1979 EDITION BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT COLLINS as folloGNs Section 1 That Section 1205(a) of the Uniform Building Code 1979 Edition is amended by adaing an exception after the fourth paragraph to read as follows EXCEPTION Light and ventilation for an interior room may be supplied from an adjoining exterior room provided the following conditions are met (1) The common wall is provided with openable interior openings with an aggregate area of not less than one-twentieth of the floor area of the interior room (2) The adjoining exterior room has openable exterior openings for light and ventilation as requirea in this section, plus additional such openings not less in area than twice the amount required for the interior room Section 2 That Table No 29A of the Uniform Building Code 1979 Edition is amended to read as follows TABLE NO 29A FOUNDATION! FOR STUD BEARING WALLS - MINIMUM REQUIREMENTS DEPTH OF THICKNESS OF FOUNDATION FOUNDATION WALL BELOW NATURAL (INCHES) HEIGHT OF SURFACE OF UNIT FOUNDATION WIDTH OF THICKNESS GROUND AND NUMBER OF1 MASONRY WALL FOOTING OF FOOTING FINISH GRADE STORIES CONCRETE (NOMINAL) (IN FEET) ( INCHES) ( INCHES) ( INCHES) 1 5-1/2 6 2 3 or less 5 16 8 30 7-1/2 8 2 3-9 4 5 2 Same as Same as Same as 20 10 30 Required Required Required for 1 for 1 for 1 Story Story Story 3 9-1/2 10 Same as 24 12 30 Required for 1 Story 1 For the purpose of Table No 29A only, one (1) story means one (1) roof load plus one (1) floor load, two (2) stories means one (1) roof load plus two (2) floor loads, and three (3) stories means one (1) roof load plus three (3) floor loads 2 The minimum reinforcement for masonry foundations shall be as follows (a) Footing shall be reinforced with two #4 bars located not less than three inches (3") from the bottom or sides of the footing (b) Foundation walls shall be reinforced with #4 vertical bars spaced a maximum of four feet (4' ) on center Vertical bars shall be bent so as to form a minimum horizontal extension of six inches (6") and shall be tied to a longitudinal bar All cells containing the vertical reinforcement shall be filled solidly with grout (c) Horizontal reinforcement shall consist of approved wire reinforce- ment with a minimum of 9 gauge side and cross runs Such rein- forcement shall be laid continuously in alternate bed joints -2- (d) The top course of foundation walls shall be a bond beam course Bond beam courses for ► alls three feet (3' ) or less in height snalI be reinfor ced with one #4 bar Bond beam courses for walls three (3' ) to nine feet (9' ) in height shall be reinforced tiiith two #4 bars Vertical bars shall be tied to the bond beam longitudinal bars 3 Concrete foundation walls three feet (31 ) or less in height shall be reinforced with one (1) #4 bar located not less than th, ee inches (3") nor more than six inches (6") from the top of the wall and one (1) #4 bar located not less than three inches (3") nor more than sic incnes (6") from the bottom of the wall The bars shall be centered within the width of the wall 4 Concrete foundation walls three feet (3' ) to nine feet (9' ) in height shall be reinforced with two #4 bars located not less than three inches (3") nor more than six inches (6") from the top of the wall and two (2) #4 bars located not less than three inches (3") nor more tnan six inches (6") from the bottom of the wall The bars shall be placed not less than one and one-half inches (1-112") from the vertical edges of the wall 5 Minimum reinforcing for normal conditions Walls subject to excessive surciiar ge loads or lateral pressures created by unstable soil or ground water conditions shall be designed with accepted engineering practices Section 3 That the Appendix to Chapter 11 of the Uniform Building Code 1979 Edition is amended by adding an exception at the end of Item 4 of Section 1107 to read as follows EXCEPTION Greenhouses and similar structures attached to Group R occupancies for the purpose of providing light and ventilation not exceed- ing 15/ of the floor area of the dwelling unit may be classified as Group R occupan- cies Section 4 That the Appendix to Chapter 32 of the Uniform Building Code 1979 Edition is amended by adding to the last sentence of Section 3212 Item 1 , the following "or other approved methods" and by changing Item No 3 to read as follo� s #3 Wood Shingle Application Wood shingles shall not be applied over existing wood sningles " and by changing Item 5 to read as follows -3- 11 5 Rusted, danagPd or inadequate flashing, vent caps and metal edgings shall be replaced with nerr mates ials as necessary and as approved by the Building Official " Introduced, considered favorably on first reading and o dered pub- lished this 16th day of December 198 d to be present for final passage on the Ith day o January 81 Mayor �ATTEST City Clerk 1981 Passed and adopted on final reading thi 6th day of January , r/ NATTEST City Clerk -4-