ORDINANCE NO 23 1975
BEING AN ORDINANCE AMENDING ARTICLE I
OF CHAPTER 38 OF THE CODE OF THE CITY
OF FORT COLLINS AND THE BUILDING CODE
ADOPTED THEREBY
BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT COLLINS
That the Uniform Building Code, 1973 Edition adopted by
Article I of Chapter 38 of the Code of the City of Fort Collins
be and the same hereby is amended by amending Section 1711(a)
of said Uniform Building Code to read as follows
' Section 1711(a) Floors and Walls--Non-dwelling
Units
"In other than dwelling units toilet room floors
shall have a smooth hard non-absorbent surface
such as Portland cement concrete ceramic the
quarry the sheet vinyl inlay not less than
075 thickness - wear thickness not less than
035" monolithic seamless floor systems (when
installed over concrete) ceramic floor system
incorporating non-absorbent backing materials
when installed with Waterproof adhesives and
other approved materials Non-absorbent materials
shall extend upward onto the walls at least 4"
' Where vinyl inlay or seamless systems are
extended upwards the junction at floor and
wall shall be coved Ceramic and quarry type
bases may be installed with vinyl or seamless
coverings if set with waterproof adhesives
Walls within water closet compartments and
walls within two (2) feet of the front and sides
of urinals shall be similarly finished with
approved materials to a height of four (4)
feet and except for structural elements the
materials used in such walls shall be of a
type which is not adversely affected by
moisture
"EXCEPTION
1 In heavy traffic area with uncontrolled
use of toilet facilities such as service stations
transportation terminals, food and drink estab-
lishments public toilet facilities and open
mall toilets floor covering shall not include
sheet vinyl inlay
12 Carpet and other floor coverings may be
installed in private individual toilets with
restricted access "
Said Uniform Building Code is further amended by changing
Exception 4 in Section 503 (d) of the Uniform Building Code
to read as follows
14 In the indicated one hour occupancy separa-
tion between Group I and J occupancy the
separation may be limited to the installation
of materials having a U L Class F-45 rating
and a tight fitting solid wood door 1-3/8
inches in thickness will be permitted in lieu
of a rated fire assembly Fire dampers shall
not be required in ducts piercing this
separation provided they are constructed
of number 26 gauge galvanized steel
Introduced considered favorably on first reading and
ordered published this 18th day of March A D 1975 'and to be
presented for final passage on the 1st day of April A D 1975