HomeMy WebLinkAbout017 - 02/20/1979 - AMENDING THE UNIFORM BUILDING CODE INSOFAR AS IT RELATES TO LIGHT AND VENTILATION L
ORDINANCE NO 17 , 1979
BEING AN ORDINANCE AMENDING THE
UNIFORM BUILDING CODE INSOFAR AS
IT RELATES TO LIGHT AND VENTILATION
BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT COLLINS as follows
Section 1 That Section 1305 (a) of the Uniform Building Code, 1976
Edition, be, and it hereby is, amended to read as follows
"§1305 (a) Liqht and Ventilation All guest rooms,
dormitories and habitable rooms within a
dwelling unit shall be provided with
natural light by means of exterior glazed
openings with an area not less than
one-tenth of the floor area of such rooms
with a minimum of 10 square feet All
bathrooms, water closet compartments,
laundry rooms and similar rooms shall be
provided with natural ventilation by
means of openable exterior openings with
an area not less than one-twentieth of
the floor area of such rooms with a
minimum of 1 112 square feet
EXCEPTION Artificial light may be
substituted for natural light for all
habitable rooms in basements other than
sleeping rooms provided such roons du nVAL
constitute a basement dwelling unit
All guest rooms, dormitories and habit-
able rooms within a duelling unit shall
be provided with natural ventilation by
means of openable exterior openings with
an area of not less than one-twentieth of
the floor area of such rooms with a
minimum of 5 square feet
EXCEPTION The area of openable exterior
openings for the purpose of natural
ventilation may be decreased to one (1 )
percent of the floor area for all habit-
able rooms with exterior walls in base-
ments, other than sleeping rooms provided
such rooms do not constitute a basement
dwelling unit
In lieu of required exterior openings for
natural ventilation, a mechanical venti-
lating system may he provided Such
system shall be capable of providing two
air changes per hour in all guest rooms,
dormitories, habitable rooms, and in
public corridors One-fifth of the air
supply shall be taken from the outside
In bathrooms, water closet compartments,
laundry rooms , and similar rooms a
mechanical ventilation system connected
directly to the outside, capable of
providing five air changes per hour,
shall be provided
For the purpose of determining light and
ventilation requirements, any room may be
considered as a portion of an adjoining
room when one-half of the area of the
common wall is open and unobstructed and
provides an opening of not less than
one-tenth of the floor area of the
interior room or 25 square feet, which-
ever is greater
Required exterior openings for natural
light and ventilation shall open directly
onto a street or public alley or a yard
or court located on the same lot as the
building
EXCEPTION Required windows may open
into a roofed porch where the porch
1) Abuts a street , yard , or court ,
and
2) Has a ceiling height of not less than
7 feet, and
3) Has the longer side at least 65
percent open and unobstructed "
Section 2 That Section 1405 (a) of the Uniform Building Code, 1976
Edition, be, and it hereby is amended to read as follows
"Sec 1405 (a) Light and Ventilation All guest rooms,
dormitories, and habitable rooms within a
dwelling unit shall be provided with
natural light by means of exterior glazed
openings with an area not less than one-
-2-
tenth of the floor area of such rooms with
a minimum of 10 square feet All bath-
rooms, water closet compartments, laundry
rooms and similar rooms shall be provided
with natural ventilation by means of
openable exterior openings with an area
not less than one-twentieth of the floor
area of such rooms with a minimum of 1 112
square feet
EXCEPTION Artificial light may be
substituted for natural light for all
habitable rooms in basements other than
sleeping rooms provided such rooms do not
constitute a basement dwelling unit
All guest rooms, dormitories and habit-
able rooms within a dwelling unit shall
be provided with natural ventilation by
means of openable exterior openings with
an area of not less than one-twentieth of
the floor area of such rooms with a
minimum of 5 square feet
EXCEPTION The area of openable exterior
openings for the purpose of natural
ventilation may be decreased to one (1 )
percent of the floor area for all habit-
able rooms with exterior walls in base-
ments, other than sleeping rooms provided
such rooms do not constitute a basement
dwelling unit
In lieu of required exterior openings for
natural ventilation, a mechanical venti-
lating system may be provided Such
system shall be capable of providing two
air changes per hour in all guest rooms,
dormitories, habitable rooms, and in
public corridors One-fifth of the air
supply shall be taken from the outside
In bathrooms, water closet compartments,
laundry rooms , and similar rooms a
mechanical ventilation system connected
directly to the outside , capable of
providing five air changes per hour,
shall be provided
For the purpose of determining lignt and
ventilation requirements, any room may be
considered as a portion of an adjoining
-3-
room when one-half of the area of the
common wall is open and unobstructed and
provides an opening of not less than
one-tenth of the floor area of the
interior room or 25 square feet, which-
ever is greater
Required exterior openings for natural
light and ventilation shall open directly
onto a street or public alley or a yard
or court located on the same lot as the
building
EXCEPTION Required windows may open
into a roofed porch where the porch
1 ) Abuts a street , yard , or court,
and
2) Has a ceiling height of not less
than 7 feet, and
3) Has the longer side at least 65
percent open and unobstructed "
Introduced, considered favorably on first reading, and ordered pub-
lished this 6th day of February, A D 1979, and�o be presented for
final passage on the 20ttr day of February, A D 7,9�
h1 ay r
T
Ci y Clerk
Passed and adopted on final reading this 20 day of February, A D
1979
7
Ma or
ALT T
CITY—Clerk
-4-