HomeMy WebLinkAbout2603 Comet St - Disclosures/Blower Door Test - 03/20/2020Testing Company:
Name: GS Services Ltd
Address: 309 Lincoln Court
Fort Collins, CO 80524
Phone: 970-449-1612
www.GSServices.com
Technician:
Name: Paul Higman
Credentials:
Email:
Building Information:
Project ID: Hartford Homes - Mosaic
Address: 2603 Comet Street
Fort Collins, CO 80524
Geo-Tag Data: Latitude: 40.590172
Longitude: -105.028671
Timestamp: 2019-03-20 12:22:22
Customer Information:
Name: Hartford Homes
Address:
Test Results: Measured Leakage: 2.90 ACH50
Leakage Target: 3.00 ACH50
Compliance with Leakage Target: Pass
Test ID: Unit 1
Purpose of Test: IECC 12/15 Env. Leakage
Measured CFM50: 965.3 (+/- 5.4%) Effective Leakage Area: 16.1 in²
Building Volume: 19,954.0 ft³ Enclosure Surface Area: 0.0 ft²
Flow Coefficient (C): 12.0 (+/- 44.3%) Exponent (n): 1.123 (+/- 0.121)
Correlation Coefficient: 0.99425
Test Standard: ASTM E779 (single mode) Test Mode: Depressurize
Test Characteristics: Pre Indoor Temp: 69 °F
Pre Outdoor Temp: 53 °F
Altitude: 4,956.0 ft
Post Indoor Temp: 69 °F
Post Outdoor Temp: 53 °F
Time Average Period: 10 seconds
Test Date and Time: 2019-03-26 14:51:40
Envelope Leakage Test
Test Readings:
Target (Pa) Bldg (Pa) Adj Bldg (Pa) Fan (Pa) Flow (cfm) Config
Baseline -3.8
-60.0 -64.9 -62.2 -39.6 1,142.3 Ring A
-54.0 -58.0 -55.3 -30.3 1,003.6 Ring A
-48.0 -50.7 -48.0 -216.8 872.0 Ring B
-42.0 -47.3 -44.6 -180.9 797.1 Ring B
-36.0 -39.7 -37.0 -144.5 713.1 Ring B
-30.0 -34.4 -31.7 -94.1 576.7 Ring B
-24.0 -28.1 -25.4 -51.8 428.9 Ring B
-18.0 -23.7 -21.0 -29.8 326.3 Ring B
Baseline -1.6
Test Equipment:
Flow Device: Model 3 Fan
Pressure Gauge: DG700
Serial #: 41761
Calibration Date: 2018-12-26
Deviations from Standard:
n value is outside of normally accepted limits.
Comments:
House WRT Garage = -48.2 Pa
Envelope Leakage Test (Page 2)
Testing Company:
Name: GS Services Ltd
Address: 309 Lincoln Court
Fort Collins, CO 80524
Phone: 970-449-1612
www.GSServices.com
Technician:
Name: Paul Higman
Credentials:
Email:
Building Information:
Project ID: Hartford Homes - Mosaic
Address: 2603 Comet Street
Fort Collins, CO 80524
Geo-Tag Data: Latitude: 40.590172
Longitude: -105.028671
Timestamp: 2019-03-20 12:22:22
Customer Information:
Name: Hartford Homes
Address:
Test Results: Measured Leakage: 2.72 ACH50
Leakage Target: 3.00 ACH50
Compliance with Leakage Target: Pass
Test ID: Unit 2
Purpose of Test: IECC 12/15 Env. Leakage
Measured CFM50: 904.7 (+/- 2.5%) Effective Leakage Area: 36.5 in²
Building Volume: 19,954.0 ft³ Enclosure Surface Area: 0.0 ft²
Flow Coefficient (C): 44.0 (+/- 16.8%) Exponent (n): 0.773 (+/- 0.047)
Correlation Coefficient: 0.99816
Test Standard: ASTM E779 (single mode) Test Mode: Depressurize
Test Characteristics: Pre Indoor Temp: 68 °F
Pre Outdoor Temp: 58 °F
Altitude: 4,956.0 ft
Post Indoor Temp: 68 °F
Post Outdoor Temp: 58 °F
Time Average Period: 10 seconds
Test Date and Time: 2019-03-20 12:24:49
Envelope Leakage Test
Test Readings:
Target (Pa) Bldg (Pa) Adj Bldg (Pa) Fan (Pa) Flow (cfm) Config
Baseline -1.1
-60.0 -62.6 -59.9 -32.9 1,044.6 Ring A
-54.0 -54.9 -52.2 -231.1 900.0 Ring B
-48.0 -49.4 -46.7 -197.7 833.0 Ring B
-42.0 -43.8 -41.1 -155.2 738.8 Ring B
-36.0 -36.9 -34.2 -118.8 647.2 Ring B
-30.0 -30.8 -28.1 -95.8 581.7 Ring B
-24.0 -25.9 -23.2 -66.4 485.1 Ring B
-18.0 -19.2 -16.5 -39.6 375.6 Ring B
Baseline -4.3
Test Equipment:
Flow Device: Model 3 Fan
Pressure Gauge: DG700
Serial #: 41761
Calibration Date: 2018-12-26
Deviations from Standard:
None
Comments:
House WRT Garage = -47.8 Pa
Envelope Leakage Test (Page 2)
Testing Company:
Name: GS Services Ltd
Address: 309 Lincoln Court
Fort Collins, CO 80524
Phone: 970-449-1612
www.GSServices.com
Technician:
Name: Paul Higman
Credentials:
Email:
Building Information:
Project ID: Hartford Homes - Mosaic
Address: 2603 Comet Street
Fort Collins, CO 80524
Geo-Tag Data: Latitude: 40.590172
Longitude: -105.028671
Timestamp: 2019-03-20 12:22:22
Customer Information:
Name: Hartford Homes
Address:
Test Results: Measured Leakage: 2.96 ACH50
Leakage Target: 3.00 ACH50
Compliance with Leakage Target: Pass
Test ID: Unit 3
Purpose of Test: IECC 12/15 Env. Leakage
Measured CFM50: 985.8 (+/- 4.0%) Effective Leakage Area: 44.2 in²
Building Volume: 19,954.0 ft³ Enclosure Surface Area: 0.0 ft²
Flow Coefficient (C): 56.7 (+/- 29.5%) Exponent (n): 0.730 (+/- 0.082)
Correlation Coefficient: 0.99377
Test Standard: ASTM E779 (single mode) Test Mode: Depressurize
Test Characteristics: Pre Indoor Temp: 68 °F
Pre Outdoor Temp: 64 °F
Altitude: 4,956.0 ft
Post Indoor Temp: 68 °F
Post Outdoor Temp: 64 °F
Time Average Period: 10 seconds
Test Date and Time: 2019-03-20 13:05:32
Envelope Leakage Test
Test Readings:
Target (Pa) Bldg (Pa) Adj Bldg (Pa) Fan (Pa) Flow (cfm) Config
Baseline -4.6
-60.0 -65.1 -60.4 -34.9 1,075.1 Ring A
-54.0 -58.3 -53.6 -29.3 987.3 Ring A
-48.0 -47.8 -43.0 -240.7 918.0 Ring B
-42.0 -47.4 -42.7 -196.8 831.0 Ring B
-36.0 -41.1 -36.3 -159.2 748.1 Ring B
-30.0 -34.2 -29.4 -124.0 661.0 Ring B
-24.0 -29.4 -24.6 -88.1 558.1 Ring B
-18.0 -24.0 -19.3 -63.0 472.5 Ring B
Baseline -4.9
Test Equipment:
Flow Device: Model 3 Fan
Pressure Gauge: DG700
Serial #: 41761
Calibration Date: 2018-12-26
Deviations from Standard:
The interval between building pressures is greater than 10 Pa.
Comments:
House WRT Garage = -46.8
Envelope Leakage Test (Page 2)