HomeMy WebLinkAbout2232 Friar Tuck Ct - Disclosures/Final Energy - 12/19/2016Air Leakage Property LC Home Homeowner 2232 Friar Tuck Ct Ft Collins, CO 80524 Weather:Ft. Collins, CO LC Home 2232 Friar Tuck Ct LC Home REM 14.6.4.blg Organization EnergyLogic, Inc (970) 556-0839 Neal Girard Builder LC Home Whole House Infiltration ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v14.6.4 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Confirmed 12/19/16 Rating No:41690 Rater ID:4606190 Duct Leakage Ventilation Blower Door Test Heating Cooling Natural ACH 0.11 0.09 ACH @ 50 Pascals 1.82 1.82 CFM @ 25 Pascals 578 578 CFM @ 50 Pascals 907 907 Eff. Leakage Area (sq.in) 49.8 49.8 Specific Leakage Area 0.00011 0.00011 ELA/100 sf shell (sq.in) 0.74 0.74 Leakage to Outside Units CFM @ 25 Pascals 19 CFM25 / CFMfan 0.0157 CFM25 / CFA 0.0061 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 30 Eff. Leakage Area (sq.in) 1.64 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0233 Mechanical Exhaust Only ASHRAE Sensible Recovery Eff. (%) 0.0 62.2-2010 Total Recovery Eff. (%) 0.0 Rate (cfm) 70 69 Hours/Day 24.0 24.0 Fan Watts 15.0 Cooling Ventilation No Ventilation 2012 IECC Energy Cost Compliance Property LC Home Homeowner 2232 Friar Tuck Ct Ft Collins, CO 80524 Weather:Ft. Collins, CO LC Home 2232 Friar Tuck Ct LC Home REM Organization EnergyLogic, Inc (970) 556-0839 Neal Girard Builder LC Home HERS Confirmed 12/19/16 Rating No:41690 Rater ID:4606190 REM/Rate - Residential Energy Analysis and Rating Software v14.6.4 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Annual Energy Cost $/yr 2012 IECC As Designed Heating 434 391 Cooling 134 105 Water Heating 434 434 SubTotal - Used to Determine Compliance 1001 930 Lights & Appliances 737 723 Photovoltaics -0 -0 Service Charge 240 240 Total 1978 1893 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2) PASSES Window U-Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.1.2) PASSES Duct Leakage (Section 403.2.2) PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy (Section 403.5.1) PASSES Mandatory Requirements Check Box (2012 IECC) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 7.1%. Name Neal Girard Signature Organization EnergyLogic, Inc Date 19 December 2016 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 2232 Friar Tuck Ct, Ft Collins, CO by LC Home exceeds the minimum requirements for the 2012 International Energy Conservation Code The 2012 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v14.6.4 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in compliance with Chapter 4 based on Climate Zone 5B and with all mandatory requirements. Building Features Ceiling Flat R-38.0 Duct Uninsulated Name Neal Girard Signature Sealed Attic: NA Duct Leakage to Outside: 19.00 CFM @ 25 Pascals Organization EnergyLogic, Inc Date December 19, 2016 Vaulted Ceiling NA Total Duct Leakage: 73.00 CFM @ 25 Pascals Above Grade Walls R-23.0 Infiltration: Htg: 907 Clg: 907 CFM50 Foundation Walls R-19.0 Window U-Value: 0.340, SHGC: 0.310 Exposed Floor R-50.4 Heating Fuel-fired air distribution, Natural gas, 92.1 AFUE. Slab R-0.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Conventional, Electric, 0.95 EF, 50.0 Gal. Home Energy Rating Certificate HERS Index: 55 REM/Rate - Residential Energy Analysis and Rating Software v14.6.4 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. General Information Conditioned Area 3130 sq. ft. House Type Single-family detached Mechanical Systems Features Heating: Fuel-fired air distribution, Natural gas, 92.1 AFUE. Building Shell Features Ceiling Flat R-38.0 Slab R-0.0 Edge, R-0.0 Under Lights and Appliance Features Percent Interior Lighting 100.00 Range/Oven Fuel Electric Home Energy Rating Provider Estimated Annual Energy Cost Use MMBtu Cost Percent Heating 31.2 $365 20% Criteria This home meets or exceeds the minimum criteria for the following: EPA ENERGY STAR Version 3 Home Conditioned Volume 29883 cubic ft. Foundation Conditioned basement Cooling: Air conditioner, Electric, 13.0 SEER. Sealed Attic NA Exposed Floor R-50.4 Percent Garage Lighting 100.00 Clothes Dryer Fuel Electric EnergyLogic, Inc. Cooling 5.6 $57 3% 2012 International Energy Conservation Code Bedrooms 4 Water Heating: Conventional, Electric, 0.95 EF, 50.0 Gal. Vaulted Ceiling NA Window Type U-Value: 0.340, SHGC: 0.310 Refrigerator (kWh/yr) 709 Clothes Dryer EF 3.01 P.O. Box N Hot Water 14.0 $434 24% Duct Leakage to Outside 19.00 CFM25. Above Grade Walls R-23.0 Infiltration Rate Htg: 907 Clg: 907 CFM50 Dishwasher (kWh/yr) 260 Ceiling Fan (cfm/Watt) 0.00 Berthoud, CO 80513 Lights/Appliances 24.7 $723 40% Ventilation System Exhaust Only: 70 cfm, 15.0 watts. Foundation Walls R-19.0 Method Blower door test Phone # 1-800-315-0459 Photovoltaics -0.0 $-0 -0% Programmable Thermostat Heat=Yes; Cool=Yes www.nrglogic.com Service Charges $240 13% Total 75.5 $1819 100% Property HERS LC Home Rating Type: Confirmed Certified Energy Rater: Neal Girard LC Home Homeowner Rating Date: 12/19/16 Rating Number: 41690 2232 Friar Tuck Ct Registry ID: 182274557 Ft Collins, CO 80524 Certified Energy Rater: