Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1651 Freewheel Dr - Disclosures/Final Energy - 05/15/2016
AIR LEAKAGE REPORT Date: May 15, 2016 Rating No.: 39553 Building Name: Cross Creek Builders LLC Rating Org.: EnergyLogic, Inc Owner's Name: Cross Creek Builders LLC Homeo Phone No.: (970) 556-0839 Property: 1651 Freewheel Dr Rater's Name: Brad Smith Address: Ft Collins, CO 80525 Rater's No.: 8809000 Builder's Name: Cross Creek Builders LLC Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 1651 Freewheel Dr Cross Creek Builders LLC RE Rating Date: 5/3/16 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. Whole House Infiltration Blower door test Heating Cooling Natural ACH: 0.14 0.11 ACH @ 50 Pascals: 2.93 2.93 CFM @ 25 Pascals: 913 913 CFM @ 50 Pascals: 1432 1432 Eff. Leakage Area: [sq.in] 78.6 78.6 Specific Leakage Area: 0.00018 0.00018 ELA/100 sf shell: [sq.in] 1.21 1.21 Duct Leakage Leakage to Outside Units Main CFM @ 25 Pascals: 0 CFM25 / CFMfan: 0.0000 CFM25 / CFA: 0.0000 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 0 Eff. Leakage Area: [sq.in] 0.00 Thermal Efficiency: N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage: 0.0000 Ventilation Mechanical: Exhaust Only ASHRAE Sensible Recovery Eff. (%): 0.0 62.2-2010 Total Recovery Eff. (%): 0.0 Rate (cfm): 61 61 Hours/Day: 24.0 24 Fan Watts: 15.0 Cooling Ventilation: Natural Ventilation Regarding ASHRAE 62.2 Ventilation Compliance The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. COMPONENT LOAD SUMMARY Date: May 15, 2016 Rating No.: 39553 Building Name: Cross Creek Builders LLC Rating Org.: EnergyLogic, Inc Owner's Name: Cross Creek Builders LLC Homeo Phone No.: (970) 556-0839 Property: 1651 Freewheel Dr Rater's Name: Brad Smith Address: Ft Collins, CO 80525 Rater's No.: 8809000 Builder's Name: Cross Creek Builders LLC Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 1651 Freewheel Dr Cross Creek Builders LLC RE Rating Date: 5/3/16 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. Cross Creek Builders LLC HEATING SEASON (MMBtu/yr) Ceilings/Roofs 4.7 Rim/Band Joists 1.2 Above Grade Walls 17.1 Foundation Walls 7.9 Doors 1.1 Windows/Skylights 10.2 Floors 0.0 Crawl Space/Unht Bsmt 0.0 Slab Floors 3.5 Infiltration 4.5 Mechanical Ventilation 9.3 Ducts 0.0 Active Solar 0.0 Sunspace 0.0 Internal Gains -15.2 Total 44.3 Cross Creek Builders LLC 2012 IECC ANNUAL ENERGY COST COMPLIANCE Date: May 15, 2016 Rating No.: 39553 Building Name: Cross Creek Builders LLC Rating Org.: EnergyLogic, Inc Owner's Name: Cross Creek Builders LLC Homeo Phone No.: (970) 556-0839 Property: 1651 Freewheel Dr Rater's Name: Brad Smith Address: Ft Collins, CO 80525 Rater's No.: 8809000 Builder's Name: Cross Creek Builders LLC Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 1651 Freewheel Dr Cross Creek Builders LLC RE Rating Date: 5/3/16 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. Annual Energy Cost ($) 2012 IECC As Designed Heating: 363 342 Cooling: 127 95 Water Heating: 98 98 SubTotal - Used to Determine Compliance: 589 535 Lights & Appliances: 637 626 Photovoltaics: -0 -0 Service Charge: 240 240 Total: 1466 1401 * Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.302 Home Infiltration (Section 402.4.1.2): PASSES Duct Leakage (Section 403.2.2): PASSES Mechanical Ventilation (Section 403.5): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2012 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 9.2%. Name: Brad Smith Signature: Organization: EnergyLogic, Inc Date: May 15, 2016 * Design energy cost is based on the following systems: Heating: Fuel-fired air distribution, 56.0 kBtuh, 92.1 AFUE. Water Heating: Conventional, Gas, 0.68 EF. Cooling: Air conditioner, 12.9 kBtuh, 13.0 SEER. Window-to-Floor Area Ratio: 0.10 2012 IECC ANNUAL ENERGY COST COMPLIANCE Cross Creek Builders LLC Page 2 REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado. Blower door test: Htg: 1432 Clg: 1432 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2012 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. 2012 IECC Certificate 1651 Freewheel Dr, Ft Collins, CO 80525 Building Envelope Insulation Ceiling: R-38.0 Above Grade Walls: R-23.0 Foundation Walls: R-23.0 Exposed Floor: NA Slab: R-0.0 Edge, R-0.0 Under Infiltration: Htg: 1432 Clg: 1432 CFM50 Duct: NA Total Duct Leakage: 0.00 CFM @ 25 Pascals Window Data U-Factor SHGC Window: 0.300 0.250 Mechanical Equipment HEAT: Fuel-fired air distribution, Natural gas, 92.1 AFUE. COOL: N/A DHW: Conventional, Natural gas, 0.68 EF, 48.0 Gal. Builder or Design Professional Signature _________________________________________ REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 Cross Creek Builders LLC 1651 Freewheel Dr Ft Collins, CO 80525 5 Stars Plus Confirmed Registry ID: 263233639 Rating Number: 39553 Certified Energy Rater: Brad Smith Rating Date: 5/3/16 Rating Ordered For: Cross Creek Builders LLC Homeo Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 49.3 $324 25% Cooling 0 $0 0% Hot Water 16.4 $99 8% Lights/Appliances 23.8 $626 49% Photovoltaics -0.0 $-0 -0% Service Charges $240 19% Total 90.9 $1288 100% This home meets or exceeds the minimum criteria for all of the following: 2012 International Energy Conservation Code Home Energy Rating Provider EnergyLogic, Inc. P.O. Box N Berthoud, CO 80513 Phone # 1-800-315-0459 www.nrglogic.com Certified Energy Rater Uniform Energy Rating System 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less Energy Efficient HERS Index: 52 General Information Conditioned Area: 3116 sq. ft. HouseType: Single-family detached Conditioned Volume: 29279 cubic ft. Foundation: Conditioned basement Bedrooms: 3 Mechanical Systems Features Heating: Fuel-fired air distribution, Natural gas, 92.1 AFUE. Water Heating: Conventional, Natural gas, 0.68 EF, 48.0 Gal. Duct Leakage to Outside: 0.00 CFM25. Ventilation System: Exhaust Only: 61 cfm, 15.0 watts. Programmable Thermostat: Heating: Yes Cooling: Yes Building Shell Features Ceiling Flat: R-38.0 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: NA Vaulted Ceiling: NA Window Type: U-Value: 0.300, SHGC: 0.250 Above Grade Walls: R-23.0 Infiltration Rate: Htg: 1432 Clg: 1432 CFM50 Foundation Walls: R-23.0 Method: Blower door test Lights and Appliance Features Percent Interior Lighting: 100.00 Range/Oven Fuel: Natural gas Percent Garage Lighting: 100.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 563.00 Clothes Dryer EF: 3.01 Dishwasher (kWh/yr): 260.00 Ceiling Fan (cfm/Watt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. © 1985-2015 Noresco, Boulder, Colorado.