HomeMy WebLinkAbout4803 Boardwalk Dr - Special Inspections/Engineering - 02/17/2017February 17, 2017
Aspen Summit, LLC
1223 Red Oak Court
Fort Collins, Colorado 80525
Attn: Mr. Jesus Martin-Roman (martinj(a1forrcollin ·peri donti ·t.com)
EARTH ENGINEERING
CONSULTANTS, LLC
Re: Construction Observation and Materials Testing Report - Final Summary Report
Angie Lee Periodontics - 4803 Boardwalk Drive
Fort Collins, Colorado
EEC Project No. 1164091
Mr. Martin-Roman:
As you are aware, during vanous construction phases for the recently completed Angie Lee
Periodontics project located at 4803 Boardwalk Drive in Fort Collins, Colorado, Earth Engineering
Consultants, LLC (EEC) personnel, provided construction observation and testing services of
requested items on a part-time/periodic, as-needed/on-call basis as scheduled by the project's
general contractor, Elder Construction as per the project specifications. Bi-monthly construction
materials testing (CMT)/quality control (QC) reports concerning the services provided by EEC
personnel were submitted to Aspen Summit, LLC (owner) and to Elder Construction, (the general
contractor and owner's representative) during the appropriate time period(s) as the test results
became available. We have recently been asked by Mr. Justin Robinson, project superintendent
with Elder Construction, to provide a summary letter addressing the services performed by EEC
personnel regarding but not limited to the foundation system, the interior floor slab, any structural
related elements, and structural steel erection components/non-destructive testing/NOT services for
the project.
During the foundation construction phase for the referenced project, EEC personnel provided site
observations and testing services of the foundation/footing system, including the over-excavation
and replacement concept to allow for conventional spread footings as a swell mitigation approach
for the new building footprint addition. The site observations and testing services during the
foundation and interior floor slab construction phases were performed and completed, as
recommended in the project-specific subsurface exploration report, (please refer to EEC's
"Subsurface Exploration Report" dated November 2, 2015, EEC Project No. 1152104).
4396 GREENFIELD DRIVE
WINDSOR, COLORADO 80550
(970) 545-3908 FAX (970) 663-0282
Angie Lee Periodontics - 4803 Boardwalk Drive
Fort Collins, Colorado
EEC Project No. 1164091
February 17, 20 l 7
Page 2
Earth Engineering Consultants, LLC
EEC personnel provided site observations and field density testing during the over-excavation and
replacement approach for the building footprint backfill zone material, which was placed and
compacted as engineered fill material to enhance the bearing strata and underslab subgrades as per
the project specifications. EEC personnel provided observation of the foundation system, (i.e., the
conventional-type spread footings), and the interior floor slab reinforcement requirements. EEC
personnel also provided testing of cast-in-place concrete for the foundation system and the interior
floor slab.
EEC personnel provided reinforcement observation of the foundation system(s) including the
conventional spread footings placed on approved engineered/controlled fill material, cast-in-place
foundation walls, and interior floor slab. EEC personnel provided testing of all cast-in-place
concrete for the foundation system, interior floor slab and the exterior concrete flatwork areas.
Based on our review of the outlined testing, as directed by the general contractor and completed by
EEC personnel on an as-needed basis, the final field density test results within the building
footprint, and associated exterior flatwork, along with site utilities, met the project compaction
requirements for fill materials placed and compacted to redevelop the foundation bearing strata,
interior floor slab elevations, backfill placed adjacent to foundation walls and within on-site utility
trenches. Laboratory compressive strength tests completed on the cast-in-place concrete for
foundation elements and floor slabs, conformed to the project specified minimum 28-day
compressive strengths requirements.
Observations of reinforcement within each of the foundation systems for the project, (i.e., the cast-
in-place conventional spread footings, cast-in-place foundation walls/stem walls) were completed
by EEC personnel and reports were submitted to your attention during the appropriate periods as the
results became available. Based on our review of the outlined observations, we believe the
reinforcement within the foundation system and structural related elements were placed and
constructed in general compliance with the project plans and specifications and associated RFI's
specific to the project.
Observations for the structural steel erection, welding and bolt connections were completed by
EEC's in-house ICC Bolt and Weld *Inspector, and reports were submitted to your attention during
the appropriate period as the results became available. Based on information received, we believe
Angie Lee Periodontics - 4803 Boardwalk Drive
Fort Collins, Colorado
EEC Project No. 1164091
February 17, 2017
Page 3
Earth Engineering Consultants. LLC
the structural steel, weld, and bolted connections were in general compliance with the project plans
and specifications.
Additional copies of our six (6) periodic/bi-monthly construction materials testing (CMT)/quality
control (QC) test reports dated October 15, 2016 - Submittal No. 1, November 8, 2016 - Submittal
No. 2, November 18, 2016 - Submittal No. 3, December l, 2016 - Submittal No. 4, December 15,
2016- Submittal No. 5, and January 4, 2017 - Submittal No. 6 are available upon request.
We appreciate the opportunity to be of service to you on this project. If you have any questions
regarding this report or if we can be of further service to you in any other way, please do not
hesitate to contact us.
Very truly yours,
David A. Richer, P.E.
Senior Geotechnical Engineer
"fnspectorllnspection: The visual observation of constmction to permit the Consultant (EEC). as an experienced and qualified
professio11al, to determine that the Work. when completed by tire Contractor. generally confom1s 10 tire Contract Documents. In
making such inspections, the Consultant makes 110 guarantees for, and has no authority or control over. the Contractor's
performance or failure IO perfom1 the Work in accordance with the Contract Documents. The Consultant has 110 responsibility for
tire means. methods. techniques, sequences or procedures selected by the Contractor or for the Contractor's safety precautions a11d
programs norforfailure by the Contractor to comply ll'ith any laws or regulations relating to the perfomiance orfi1rnishing of the
Work by tire Contractor.
cc: Elder Construction - Mr. Justin Robinson (1ustin.r hin~unca eldt:n.:onstructioninc.com)
Elder Construction - Mr. Dale Wellmon (dalc.wellmonra d<ll.!r 'lln tru ·t i nin ·. 'lm )