Loading...
HomeMy WebLinkAbout2520 Nancy Gray Ave - Disclosures/Blower Door Test - 12/07/2020BUILDING LEAKAGE TEST L&L Home Performance 401 N Link Ln Fort Collins, CO 80524 Phone: 970.221.3180 Fax: 970.568.0690 Email: llinsulationjh@gmail.com Website: www.ll-insulation.com Date of Test: 12/7/2020 Test File: 2520 Nancy Gray Ave Technician: Justin Heldenbrand Project Number: Customer: Bellisimo Inc Nico Campana 3702 Manhattan Ave ste 201 Fort Collins, CO 80526 Phone: 970.402.0919 Email: ncampana@bellisimoinc.com Building Address: 2520 Nancy Gray Ave Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1244 CFM50 ( +/- 1.7 %) (50 Pa = 0.2 w.c.) 1.89 ACH50 2. Leakage Area: 68.4 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 103.2 ( +/- 13.0 %) Exponent (n) = 0.636 ( +/- 0.036 ) Correlation Coefficient = 0.99843 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 80.3 CFM 0.12 ACH 16.1 CFM per person 2. Estimated Design Infiltration Rate: Winter: 136.4 CFM 0.21 ACH Summer: 85.6 CFM 0.13 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 12/7/2020 Test File: 2520 Nancy Gray Ave Building Information Volume 39528 Surface Area 10239 Floor Area 3802 Height 28 # of Bedrooms 4 # of Occupants 5 Year of Construction 2020 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 43466-7-700 - Micromanometer Energy Conservatory DG700 43466 9/15/2016 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 12/7/2020 Test File: 2520 Nancy Gray Ave Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 64.0 54.0 5003.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -4.4 n/a n/a -64.4 -60.9 58.8 1385 1393 -1.3 Ring A -58.6 -55.2 51.6 1300 1308 -1.3 Ring A -51.2 -47.7 44.5 1210 1216 0.7 Ring A -46.8 -43.4 39.2 1136 1143 0.6 Ring A -40.5 -37.0 32.1 1032 1038 1.0 Ring A -34.5 -31.0 248.3 933 938 2.2 Ring B -28.5 -25.0 180.4 796 800 0.0 Ring B -23.0 -19.6 126.4 667 671 -2.0 Ring B -2.6 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 12/7/2020 Test File: 2520 Nancy Gray Ave Comments BPI BA and Infiltration & Duct Leakage Certification ID:5060608 Connection to Mech:-50pa Connection to Garage:-49pa