Loading...
HomeMy WebLinkAbout2420 Ridge Top Dr - Disclosures/Blower Door Test - 11/17/2020BUILDING LEAKAGE TEST Date of Test: 11/17/2020 Test File: 2420 Ridge Top Dr Unit 1 3.00 ACH 11.17.2020 Technician: Sam Chaney/ EnergyLogic Project Number: Customer: Saint Aubyn Phone: Fax: Building Address: 2420 Ridge Top Dr Unit 1 Fort Collins, CO 80526 Test Results at 50 Pascals: cfm50 Airflow 868 (+/- 2.5 %) ACH50 3.00 Leakage Areas: 65.1 in² (+/- 7.0 %) Canadian EqLA @ 10 Pa 28.9 in² (+/- 11.5 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 31.4 (+/- 18.6 %) Exponent (n) = 0.848 (+/- 0.051) Correlation Coefficient = 0.99947 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 11/17/2020 Test File: 2420 Ridge Top Dr Unit 1 3.00 ACH 11.17.2020 Building Information Volume (ft³) 17334.0 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 27 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 11/17/2020 Test File: 2420 Ridge Top Dr Unit 1 3.00 ACH 11.17.2020 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 66.0 66.0 Post-Test 66.0 66.0 Average 66.0 66.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -20.0 -20.0 38.9 372 395 -1.0 Ring B -30.0 -30.0 82.1 539 572 1.7 Ring B -40.0 -40.0 128.5 673 714 -0.6 Ring B -50.0 -50.0 193.9 825 876 0.9 Ring B -60.0 -60.0 26.8 945 1003 -1.0 Ring A 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 11/17/2020 Test File: 2420 Ridge Top Dr Unit 1 3.00 ACH 11.17.2020 Comments 48 Pa house to garage connection