Loading...
HomeMy WebLinkAbout414 Skyraider Way - Disclosures/Blower Door Test - 06/17/2020BUILDING LEAKAGE TEST GS Services, LTD. 309 Lincoln Court Fort Collins, CO 80524 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 6/17/2020 Test File: Hartford - 414 Skyraider Way Unit 1 - Akin - BDma Technician: Nick Hiseler Project Number: Customer: Hartford Homes Building Address: 414 Skyraider Way Unit 1 Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 1032 CFM50 ( +/- 1.3 %) (50 Pa = 0.2 w.c.) 2.87 ACH50 2. Leakage Area: 56.7 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 143.0 ( +/- 11.1 %) Exponent (n) = 0.505 ( +/- 0.030 ) Correlation Coefficient = 0.99774 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/17/2020 Test File: Hartford - 414 Skyraider Way Unit 1 - Akin - BDma Building Information Volume 21558 Surface Area Floor Area Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/17/2020 Test File: Hartford - 414 Skyraider Way Unit 1 - Akin - BDma Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 79.0 65.0 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.5 n/a n/a -60.0 -60.5 40.2 1151 1137 0.1 Ring A -55.0 -55.5 37.6 1114 1101 1.2 Ring A -50.0 -50.5 33.4 1052 1039 0.2 Ring A -45.0 -45.5 28.9 980 968 -1.6 Ring A -40.0 -40.5 25.4 920 909 -2.0 Ring A -35.0 -35.5 225.4 889 878 1.2 Ring B -30.0 -30.5 194.8 827 817 1.6 Ring B -25.0 -25.5 155.3 739 730 -0.6 Ring B -20.0 -20.5 125.5 665 657 -0.1 Ring B 0.5 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/17/2020 Test File: Hartford - 414 Skyraider Way Unit 1 - Akin - BDma Comments House WRT Garage = -45.0 Pa