Loading...
HomeMy WebLinkAbout310 Vicot Way - Disclosures/Blower Door Test - 03/02/2020BUILDING LEAKAGE TEST Date of Test: 3/2/2020 Test File: 310 Vicot Way 2.98ACH 3.10.2020 Technician: Trevor Donnelly (EnergyLogic) Project Number: Customer: Lennar Phone: Fax: Building Address: 310 Vicot Way Fort Collins, CO 80521 Test Results at 50 Pascals: cfm50 Airflow 929 (+/- 4.9 %) ACH50 2.98 Leakage Areas: 63.0 in² (+/- 13.9 %) Canadian EqLA @ 10 Pa 26.4 in² (+/- 22.9 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 26.4 (+/- 36.8 %) Exponent (n) = 0.910 (+/- 0.101) Correlation Coefficient = 0.99818 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 90 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/2/2020 Test File: 310 Vicot Way 2.98ACH 3.10.2020 Building Information Volume (ft³) 18705 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 20 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/2/2020 Test File: 310 Vicot Way 2.98ACH 3.10.2020 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 65.0 35.0 Post-Test 65.0 35.0 Average 65.0 35.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -60.0 -60.0 36.8 1103 1078 -1.7 Ring A -50.0 -50.0 26.6 941 920 -1.0 Ring A -40.0 -40.0 180.8 797 779 2.7 Ring B -30.0 -30.0 106.1 612 598 2.5 Ring B -20.0 -20.0 45.7 403 394 -2.3 Ring B 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3/2/2020 Test File: 310 Vicot Way 2.98ACH 3.10.2020 Comments House to garage: -49 pass