HomeMy WebLinkAbout401 Linden St - Disclosures/Blower Door Test - 01/08/2020Testing Company:
Name: GS Services Ltd
Address: 309 Lincoln Court
Fort Collins, CO 80524
Phone: 970-449-1612
www.GSServices.com
Technician:
Name: Nick Hiseler
Credentials:
Email:
Building Information:
Project ID: Saunders Heath
Address: 401 Linden Street
Fort Collins, CO 80524
Geo-Tag Data: Latitude: 40.590942
Longitude: -105.072921
Timestamp: 2019-12-19 11:14:37
Customer Information:
Name: Saunders Heath
Address: 1212 Riverside Ave
Suite 130
Fort Collins, CO 80524
Test Results: Measured Leakage: 0.25 CFM50/ft² (enclosure area)
Leakage Target: 0.30 CFM50/ft² (enclosure area)
Compliance with Leakage Target: Pass
Test ID: Unit 312
Purpose of Test: CFM/sq ft
Measured ACH50: 0.00 (+/- 0.6%) Effective Leakage Area: 38.0 in²
Building Volume: 0.0 ft³ Enclosure Surface Area: 3,014.0 ft²
Flow Coefficient (C): 51.8 (+/- 4.6%) Exponent (n): 0.685 (+/- 0.013)
Correlation Coefficient: 0.99983
Test Standard: ASTM E779 (single mode) Test Mode: Depressurize
Test Characteristics: Pre Indoor Temp: 68 °F
Pre Outdoor Temp: 40 °F
Altitude: 5,006.0 ft
Post Indoor Temp: 68 °F
Post Outdoor Temp: 40 °F
Time Average Period: 10 seconds
Test Date and Time: 2020-01-08 11:02:50
Envelope Leakage Test
Test Readings:
Target (Pa) Bldg (Pa) Adj Bldg (Pa) Fan (Pa) Flow (cfm) Config
Baseline -2.0
-60.0 -60.5 -59.1 -212.3 862.9 Ring B
-54.0 -56.8 -55.4 -193.0 823.1 Ring B
-48.0 -50.7 -49.3 -165.7 763.1 Ring B
-42.0 -44.1 -42.6 -136.8 694.0 Ring B
-36.0 -38.2 -36.8 -111.5 627.1 Ring B
-30.0 -32.8 -31.4 -90.4 565.3 Ring B
-24.0 -25.9 -24.5 -63.5 474.7 Ring B
-18.0 -19.3 -17.8 -40.1 377.7 Ring B
Baseline -0.9
Test Equipment:
Flow Device: Model 3 Fan
Pressure Gauge: DG700
Serial #: 41761
Calibration Date: 2018-12-26
Deviations from Standard:
None
Comments:
Envelope Leakage Test (Page 2)