HomeMy WebLinkAbout1057 Buckingham St - Correspondence/Building Code - 09/25/2017 (2)5/2/2016 Mike Gebo Fort Collins Building Services 281 Fort N Collins, College CO 80524 Re: Lemay Ave Self Storage - Request for Multiple Variances Dear Mr. Gebo, After our recent pre-submittal plan review meeting with Russ Hoveland with the City of Fort Collins Building Department, we are requesting you consider variances for the following code requirement items for this project: 1.) Fire Area Separation Requirement 2.) Foundation Insulation at Conditioned Edge Requirement 3.) Restroom Requirement 4.) Commission Agent Requirement 1.) 707 .3.10 - Fire Area Separation: 3 Hours between S-1 Occupancies. Table 903.1- Maximum / Allowable · Building Fire-Containment A is 16,000sf Area with no sprinklers which exceeds the 12,000sf allowance in 903.2.9 for 5- il ;&J? 1 occupancy. The storage facility has been designed and compartmentalized into 4 separate containment exit door. ln lieu areas of each using divided a 3 Hour by fire a 1 wall Hour required wall with per 20 Chapter Min doors. 9 of Each the IBC area we is are designed requesting with a its own variance to allow the building to be designed with 4 separate containment areas each below SOOOsf required by table 903.1 of the FJ ollins amendmeni' separated b� wa11. See�n below: /SD . . /'f /� a,� ( ; -f:o f ! I . 'j. ({ . .: '(Z-. �� °' · . ' '- 'rffil !513 SF I fl·:-!, � . · .. ' " 1H ..... ._ • n ' I 4962 AREA Sf I �l 9HF � L ·- -- - .. �� 12SF -··- J _ I - i, .. ..... � !- '- '- I-- - - - I-- � I-- f-- - ......., - ' -·� . '1111 ,,- q' fl. - 2- 5 - I 7 .• Galloway & Company, In::.• 303.770.8684• 6162 S. Wtllow Drive, Suite 320 • Greenwood Village, CO 80111 • www.GallowayUS.com 1057 Buckingham St l� Mike Gebo Fort Collins - Lemay Ave Storage 05/02/2016 - Additional concern is the potential of flooding. Bathrooms increase the risk of flooding and water damage to the personal property of the customers. The customers would likely rather reduce this risk, and would be satisfied with a bathroom in the office area. ' ' f L£t,V.Y AVE 1 i \,. ' ,-:.,- --·-1 r- --·- _! i__ _______ ........., 4.) 2902.3.2 - IBCC 3604.1- Commissioning Agent Requirement P ��<I!, I,.. �t fli.l!I �r..;.�1')1 �� - Per Ft Collins Amendment, section 3604.1, new buildings with a gross floor greater than 15,000sf require commissioning. The Mechanical designer of record requests a variance to the commissioning requirement for the following reasons: 1. The building in question is a storage facility, all of which is considered unoccupied space per the building and mechanical code. 2. Because it is considered unoccupied space with no building occupant load, heating, ventilation and air conditioning are provided only to the mandatory code minimums, mainly for weather protection. 3. Because occupant comfort was not a consideration in this design. equfpment startup should be considered sufficient for building functionality. We hope that this variance request letter is sufficient to provide justification for these 4 items. Please do not hesitate to reach out to us if further explanation is needed. Galloway & Company, Inc. • 303.770.8884 • 6162 S. W illow Drive, Suite 320 • Greenwood Village, CO 80111 • www.GallowayUS.com Mike Gebo Fort Collins - Lemay Ave Storage 05/02/2016 2.)- Foundation Insulation at Conditioned Edge ltv O.h�rt HIN".l.:ftt""1 In lieu of providing foundation insulation at the buildings edge where unconditioned storage units are provided per Ft Collins IECC C402.2.6 we are requesting a variance to instead provide 2" continuous insulation at the back wall of the storage unit that will be the conditioned wall of the building. We intend to have the insulation extend 2' on either side of the wall to limit any thermal bridging per detail below. --n·\r-·· I I I l:f i / 11 1 ' I ' i I i ' I I WALLSECTION t,iS • J:..,1 I . > 1' I I I 1'¥-r�UHOA"l.H.(,Jrr,UI. r'Yl,- ,:ui i:rr-'f'1-.�ru1u� 1 � I ... ,.a:�. , .. ••r• 3.) 2902.3.2 - Location of toilet facilities in occupancies other than covered mall buildings: - In lieu of providing restrooms in the 3 story storage Building C, we are requesting a variance to limit the location of the restrooms to Building A where they can be monitored near the office. The distance from the elevator lobby to restrooms in building A is 444' .Q. The distance from inside the building max to elevators is 181'-6';. + Providing bathrooms in the 3 story facility where there is no office brings up many concerns for our client, but the main concern is customer security. Storage facilities have problems with people trying to live out of units while sleeping elsewhere. This is especially true for climate-controlled storage facilities. Having the bathrooms in·close proximity of the office gives management of the opportunity to monitor and stop this type of behavior. The owner is especially concerned about the security of female customers, who will likely be responsible for renting approximately 60% of the storage units. Customers would gladly trade a bathroom in the 3 story for the enhanced security, while still having the nearby convenience of a bathroom in the office area. GaUovmy & Company, Inc. • 303.770.8884 • 6162 S. Willow Drive, Suite 320 • Greenwood Village, CO 80111 • www.GallowayUS.com