Loading...
HomeMy WebLinkAbout344 Zeppelin Way - Disclosures/Blower Door Test - 03/06/2019BUILDING LEAKAGE TEST Date of Test: 3/6/2019 Test File: 344 Zeppelin Way Tectite Technician: Trevor Donnelly - EnergyLogic Project Number: Customer: Building Address: 344 Zeppelin Way Fort Collins, CO 80521 Test Results at 50 Pascals: cfm50 Airflow 844 (+/- 3.4 %) ACH50 2.96 cfm/ft² (Floor Area) 0.6081 Leakage Areas: 80.8 in² (+/- 18.1 %) Canadian EqLA @ 10 Pa 41.2 in² (+/- 29.6 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 55.2 (+/- 47.1 %) Exponent (n) = 0.697 (+/- 0.126) Correlation Coefficient = 0.99161 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/6/2019 Test File: 344 Zeppelin Way Tectite Building Information Volume (ft³) 17087 Surface Area: (ft²) Floor Area: (ft²) 1388 Height (ft) 24 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/6/2019 Test File: 344 Zeppelin Way Tectite Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 75.0 45.0 Post-Test 75.0 45.0 Average 75.0 45.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -55.0 -55.0 236.8 911 897 -0.6 Ring B -50.0 -50.0 202.5 843 830 -1.7 Ring B -44.0 -44.0 183.1 802 789 2.2 Ring B -39.0 -39.0 149.4 725 714 0.5 Ring B -35.0 -35.0 132.4 683 672 2.1 Ring B -31.0 -31.0 101.6 599 590 -2.5 Ring B 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3/6/2019 Test File: 344 Zeppelin Way Tectite Comments House to garage: -45 PA