HomeMy WebLinkAbout316 Tigercat Way - Disclosures/Blower Door Test - 07/16/2019BUILDING LEAKAGE TEST
Date of Test: 7/16/2019 Test File: 316 Tigercat Way 2.95ACH 7.16.2019
Technician: Greydon Studer - EnergyLogic
Project Number:
Customer: Building Address: 316 Tigercat Way
Fort Collins, CO 80521
Test Results at 50 Pascals:
cfm50 Airflow 1215 (+/- 2.3 %)
ACH50 2.95
Leakage Areas: 105.3 in² (+/- 21.4 %) Canadian EqLA @ 10 Pa
50.8 in² (+/- 33.6 %) LBL ELA @ 4 Pa
Building Leakage Curve: Flow Coefficient (C) = 62.5 (+/- 52.1 %)
Exponent (n) = 0.758 (+/- 0.134)
Correlation Coefficient = 0.99205
Test Standard: E779-10
Test Mode: Depressurization
4 5 6 7 8 9 10 20 30 40 50 60 70 80
Building Pressure (Pa)
100
200
300
400
500
600
700
800
900
1000
2000
Building
Leakage
(cfm)
Depressurize ____
BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 7/16/2019 Test File: 316 Tigercat Way 2.95ACH 7.16.2019
Building Information
Volume (ft³) 24693
Surface Area: (ft²)
Floor Area: (ft²)
Height (ft) 28
Year of Construction 2019
Equipment Information
Type Manufacturer Model Serial Number Custom Calibration Date
Fan Energy Conservatory Model 3 (110V) -
Micromanometer Energy Conservatory DG700
BUILDING LEAKAGE TEST Page 3 of 4
Date of Test: 7/16/2019 Test File: 316 Tigercat Way 2.95ACH 7.16.2019
Depressurization Test:
Environmental Data
Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft)
Pre-Test 62.0 86.0
Post-Test 62.0 86.0
Average 62.0 86.0 5000.0
Data Points - Data Entered Manually (TTE 5.0.8.4)
Nominal
Building
Pressure
(Pa)
Baseline
adjusted
Building
Pressure
(Pa)
Fan
Pressure
(Pa)
Nominal
Flow
(cfm)
Adjusted
Flow
(cfm) % Error
Fan
Configuration
-1.4 n/a n/a
-65.0 -62.6 55.6 1349 1477 2.5 Ring A
-60.0 -57.6 45.2 1219 1335 -1.3 Ring A
-55.0 -52.6 38.1 1122 1229 -2.7 Ring A
-50.0 -47.6 35.1 1078 1181 0.9 Ring A
-45.0 -42.6 28.9 980 1074 -0.2 Ring A
-40.0 -37.6 231.6 901 987 0.8 Ring B
-3.4 n/a n/a
Deviations from Standard ASTM E779-10 - Test Parameters
- Pressurization test not included.
BUILDING LEAKAGE TEST Page 4 of 4
Date of Test: 7/16/2019 Test File: 316 Tigercat Way 2.95ACH 7.16.2019
Comments
House to garage -48p