Loading...
HomeMy WebLinkAbout316 Tigercat Way - Disclosures/Blower Door Test - 07/16/2019BUILDING LEAKAGE TEST Date of Test: 7/16/2019 Test File: 316 Tigercat Way 2.95ACH 7.16.2019 Technician: Greydon Studer - EnergyLogic Project Number: Customer: Building Address: 316 Tigercat Way Fort Collins, CO 80521 Test Results at 50 Pascals: cfm50 Airflow 1215 (+/- 2.3 %) ACH50 2.95 Leakage Areas: 105.3 in² (+/- 21.4 %) Canadian EqLA @ 10 Pa 50.8 in² (+/- 33.6 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 62.5 (+/- 52.1 %) Exponent (n) = 0.758 (+/- 0.134) Correlation Coefficient = 0.99205 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 7/16/2019 Test File: 316 Tigercat Way 2.95ACH 7.16.2019 Building Information Volume (ft³) 24693 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 28 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 7/16/2019 Test File: 316 Tigercat Way 2.95ACH 7.16.2019 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 62.0 86.0 Post-Test 62.0 86.0 Average 62.0 86.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.4 n/a n/a -65.0 -62.6 55.6 1349 1477 2.5 Ring A -60.0 -57.6 45.2 1219 1335 -1.3 Ring A -55.0 -52.6 38.1 1122 1229 -2.7 Ring A -50.0 -47.6 35.1 1078 1181 0.9 Ring A -45.0 -42.6 28.9 980 1074 -0.2 Ring A -40.0 -37.6 231.6 901 987 0.8 Ring B -3.4 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 7/16/2019 Test File: 316 Tigercat Way 2.95ACH 7.16.2019 Comments House to garage -48p