Loading...
HomeMy WebLinkAbout5927 Fall Harvest Way - Disclosures/Blower Door Test - 06/04/2020BUILDING LEAKAGE TEST Date of Test: 6/4/2020 Test File: 5927 Fall Harvest Wayfinal Technician: Jay- Burgess Construction Consultants Project Number: Customer: Toll Brothers Phone: Fax: Building Address: 5927 Fall Harvest Way Fort Collins, Colorado 80528 Test Results at 50 Pascals: cfm50 Airflow 1376 (+/- 0.9 %) ACH50 2.38 cfm/ft² (Floor Area) 0.3791 cfm/ft² (Surface Area) 0.1572 Leakage Areas: 104.6 in² (+/- 6.6 %) Canadian EqLA @ 10 Pa or 0.0120 in²/ft² Surface Area 46.8 in² (+/- 10.4 %) LBL ELA @ 4 Pa or 0.0054 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 51.5 (+/- 16.2 %) Exponent (n) = 0.840 (+/- 0.042) Correlation Coefficient = 0.99906 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/4/2020 Test File: 5927 Fall Harvest Wayfinal Building Information Volume (ft³) 34654 Surface Area: (ft²) 8752 Floor Area: (ft²) 3629 Height (ft) 18 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/4/2020 Test File: 5927 Fall Harvest Wayfinal Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 65.0 68.0 Post-Test 65.0 68.0 Average 65.0 68.0 4953.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -0.7 n/a n/a -65.0 -64.0 78.4 1595 1699 0.4 Ring A -60.0 -59.0 67.3 1480 1577 -0.2 Ring A -55.0 -54.0 57.4 1370 1460 -0.5 Ring A -50.0 -49.0 50.4 1286 1370 1.3 Ring A -45.0 -44.0 40.1 1150 1225 -0.8 Ring A -40.0 -39.0 32.6 1040 1108 -0.8 Ring A -35.0 -34.0 26.6 941 1003 0.8 Ring A -1.3 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/4/2020 Test File: 5927 Fall Harvest Wayfinal Comments Garage w/Respect to house @50PA = 45.4