Loading...
HomeMy WebLinkAbout630 Yarrow Cir - Disclosures/Final Energy - 01/28/2020Planning, Development & Transportation Services Community Development & Neighborhood Services Updated 11/09/2012 Simulated Performance Alternative (SPA) Cover Sheet Submittal and Rating Type  Stock Plan Permit – Projected Worst-Case Rating Builder Model: ________________________________  Lot-specific Permit - Projected Rating Address: ____________________________________  Completed Home – Confirmed Rating Address: ____________________________________ Data Required for All SPA Ratings Builder: ____________________________________ Rating Firm: _________________________________ Energy rater: ________________________________ Date: _______________________________________ Duct Location Inputs Location Supply Return % Area R-Value % Area R-Value Utility Rates Energy Source Service charge Rate Electricity $/month $/kWh Natural gas $/month $/therm Spaces considered outside the thermal boundary: _________________________________________________ Additional Information for Stock Plan Permit – Projected Worst-Case Rating “Worst-case” configuration: Foundation type(s)________________________________________________________________________ Options included _________________________________________________________________________ Orientation of front elevation ___________  Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report  Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot-Specific Permit – Projected Rating  Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report  Attach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home – Confirmed Rating  Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report (Utility rates reflected in this report must be City-approved rates on lot-specific permit application date.)  Attach Home Energy Rating Certificate 2018 IECC Energy Cost Compliance Property Mighty Hand Construction 630 Yarrow Circle Fort Collins, CO Weather:Ft. Collins, CO Mighty Hand - 630 Yarrow - Confirmed v158.blg Organization GS Services LTD 970-449-1612 Nick Hiseler Builder Mighty Hand Construction HERS Rater ID: REM/Rate - Residential Energy Analysis and Rating Software v15.8 This information does not constitute any warranty of energy costs or savings. © 1985-2019 NORESCO, Boulder, Colorado. Annual Energy Cost $/yr 2018 IECC As Designed Heating 231 239 Cooling 69 58 Water Heating 107 107 Mechanical Ventilation Fan 11 12 SubTotal - Used to Determine Compliance 418 415 Lights & Appliances (minus MechVent) 359 457 Photovoltaics -0 -0 Service Charge 240 240 Total 1017 1113 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2) PASSES Window U-Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.1) PASSES Duct Testing (Section 403.3.3) PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1) PASSES Mandatory Requirements Check Box (2018 IECC) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2018 International Energy Conservation Code based on a climate zone of 5B. In fact, this home surpasses the requirements by 0.7%. Name Nick Hiseler Signature Organization GS Services LTD Date 28 January 2020 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2018 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2018 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 630 Yarrow Circle, Fort Collins, CO by Mighty Hand Construction exceeds the minimum requirements The 2018 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.8 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in compliance with Chapter 4 based on Climate Zone 5B and with all mandatory requirements. Building Features Ceiling Flat R-49.0 Duct NA Sealed Attic: NA Duct Leakage to Outside: 30.00 CFM @ 50 Pascals Vaulted Ceiling NA Total Duct Leakage: 30.00 CFM @ 50 Pascals Above Grade Walls R-19.0 Infiltration: Htg: 748 Clg: 748 CFM50 Foundation Walls R-19.0 Window U-Value: 0.300, SHGC: 0.300 Exposed Floor NA Heating Fuel-fired air distribution, Natural gas, 96.0 AFUE. Slab R-0.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Instant water heater, Natural gas, 0.96 EF, 0.0 Gal. Name Nick Hiseler Signature Organization GS Services LTD Date 28 January 2020 2018 IECC Certificate 630 Yarrow Circle, Fort Collins, CO Building Envelope Insulation Ceiling R-49.0 Above Grade Walls R-19.0 Foundation Walls R-19.0 Exposed Floor NA Slab R-0.0 Edge, R-0.0 Under Infiltration Htg: 748 Clg: 748 CFM50 Duct NA Total Duct Leakage 30.00 CFM @ 50 Pascals Window Data U-Factor SHGC Window 0.300 0.300 Mechanical Equipment HEAT: Fuel-fired air distribution, Natural gas, 96.0 AFUE. COOL: Air conditioner, Electric, 13.0 SEER. DHW: Instant water heater, Natural gas, 0.96 EF, 0.0 Gal. Builder or Design Professional Signature REM/Rate - Residential Energy Analysis and Rating Software v15.8 Testing Company: Name: GS Services Ltd Address: 309 Lincoln Court Fort Collins, CO 80524 Phone: 970-449-1612 www.GSServices.com Technician: Name: Nick Hiseler Credentials: Email: Building Information: Project ID: Mighty Hand Construction Address: 630 Yarrow Cir Fort Collins, CO 80524 Geo-Tag Data: Latitude: 40.601328 Longitude: -105.065856 Timestamp: 2020-01-02 11:09:23 Customer Information: Name: Address: Test Results: Measured Leakage: 2.59 ACH50 Leakage Target: 3.00 ACH50 Compliance with Leakage Target: Pass Test ID: 630 Yarrow Purpose of Test: Env. Leakage Measured CFM50: 748.1 (+/- 0.9%) Effective Leakage Area: 33.3 in² Building Volume: 17,340.0 ft³ Enclosure Surface Area: 0.0 ft² Flow Coefficient (C): 42.4 (+/- 6.5%) Exponent (n): 0.733 (+/- 0.018) Correlation Coefficient: 0.99970 Test Standard: ASTM E779 (single mode) Test Mode: Depressurize Test Characteristics: Pre Indoor Temp: 63 °F Pre Outdoor Temp: 44 °F Altitude: 4,991.0 ft Post Indoor Temp: 64 °F Post Outdoor Temp: 45 °F Time Average Period: 10 seconds Test Date and Time: 2020-01-02 11:20:08 Envelope Leakage Test Test Readings: Target (Pa) Bldg (Pa) Adj Bldg (Pa) Fan (Pa) Flow (cfm) Config Baseline -5.4 -60.0 -65.5 -60.9 -213.7 865.7 Ring B -54.0 -59.4 -54.8 -181.6 798.7 Ring B -48.0 -53.9 -49.3 -154.8 738.0 Ring B -42.0 -46.6 -42.1 -128.0 671.6 Ring B -36.0 -40.8 -36.2 -100.4 595.4 Ring B -30.0 -35.5 -31.0 -79.1 528.9 Ring B -24.0 -29.8 -25.2 -58.2 454.5 Ring B -18.0 -23.4 -18.9 -37.5 365.4 Ring B Baseline -3.7 Test Equipment: Flow Device: Model 3 Fan Pressure Gauge: DG700 Serial #: 41761 Calibration Date: 2018-12-26 Deviations from Standard: None Comments: House WRT Garage = -47.5 Pa Envelope Leakage Test (Page 2)