HomeMy WebLinkAbout5915 Medlar Pl - Permits/Single Family New - 06/15/2020Owner: TOLL CO I LLC 250 GIBRALTAR RD 3RD FL HORSHAM, PA 19044-2323 Phone: 303-708-0730 Zoning: Front setback: 15.5' Rear setback: 26.6' Right setback: 6' Left setback: 6' Minor Amend #: Plat File #: ZBA Case #: Zoning district: LMN - LOW DENSITY MIXED-USE NEIGHBORHOOD DISTRICT Legal: Subdivision/PUD: KECHTER FARM FILING 2 Filing #: Lot #: 14 Block #: 4 Code: Res sq ft: 3387 Com sq ft: Ind sq ft: Basement sq ft: 0 # of stories: 2 Occ Group: Const Type: V-B Fire Sprklr: Stock plan #: Stock plan options: Contractor: TOLL BROTHERS 10 Inverness Dr. Suite 125 Englewood, CO 80112 License #: D-769 Phone: 970-901-0343 Supervisor cert #: 2125-D1 Subcontractor(s) Phone License Number Electrical: CHADWICK ELECTRIC INC 970-484-0544 ME-17 Mechanical: FORT COLLINS HEATING & AIR 970-484-4552 H-1309 Plumbing: DURANGO ENERGY AND MECHANI 303-295-3362 MP-891 Framing: NC BUILDERS, LLC 970-691-2547 F-291 Roofing: ADVANCED ROOFING TECH 970-663-0203 R-1161 Job Contact: Stephen Schwarzer 970-901-0343 Work Description: New 2 story 3387 sf single family detached residence with crawl space foundation and and 746 sf attached garage. FCLWD. Energy Compliance: Res Check with Blower Door. Job contact: Brian Kelly 970-305-0474. SCHEDULE INSPECTIONS: ** via Text Message: 888-406-6394 ** By Phone: 970-221-6769 ** Online Portal: fcgov.com/CitizenAccess ** Online Portal via Mobile Device: fcgov.com/CitizenAccess/mobile Possible Inspections Required: 103 204 105 202 102 104 203 205 201 206 207 302 300 303 200 301 TOTAL FEES PAID AS OF 06/15/20: $1,189.83 Payment method: Trust Account ** Fee Detail Displayed on Next Page As a condition for the issuance of a permit, I hereby declare that I am the owner or owner's agent, authorized to perform the proposed workonthepropertydescribedherein. I agree to comply with all the requirements contained herein, and City ordinances, and State laws associated with suchwork. I understand that such permit may be revoked in the event that issuance was basedonincorrectinformation. This permit shall become null and void if the work authorized by suchpermitisnotcommenced, suspended, abandoned or not inspected within 180 days fromthedateofsuchpermit. Carbon Monoxide Alarm required within 15 feet of each bedroom entrance. Community Development & Neighborhood Services 281 N. College Ave Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax Building Permit #: B2002450 Issued Full: 06/15/2020 Permit Type: New Single Family Detached Site Address: 5915 MEDLAR PL Job Valuation: $353,527.70 Category: Single Family Detach Res Signature: Print Name: Date: Form Revised Oct 2010 Transactions Method Check Number Date Paid Amount Paid Comments Trust Account 03/18/2020 $1,189.83 Receipt issued: 06/15/2020 Total Paid to Date: $1,189.83 Fee Description Account Code Fee Amount Amount Paid Date Paid Amount Due Plan Check Fee 1000.444010 $1,189.83 $1,189.83 03/18/2020 $0.00 TOTAL FEES: $1,189.83 $1,189.83 $0.00 TOTAL BALANCE DUE AS OF 06/15/2020: $0.00 Community Development & Neighborhood Services 281 N. College Ave Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax Building Permit #: B2002450 Issued Full: 06/15/2020 Permit Type: New Single Family Detached Site Address: 5915 MEDLAR PL Job Valuation: $353,527.70 Category: Single Family Detach Res Fee Amounts are valid for date of this document only. Fees subject to change without notice. Form Revised Oct 2010 BUILDING PERMIT APPLICATION FOR OFFICE USE APPLICATION NUMBER: APPLICATION DATE: Job Site Address Unit# 5915 Medlar Pl. PROPERTY OWNER INFO: (All owner information is required – NOT optional) Last Name First Name Middle Street Address City State Zip Phone # Email Name of Business (COMMERCIAL USE ONLY) CONTRACTOR INFO: Company Name License Holder Name LIC # CERT # LEGAL INFO: Subdivision/PUD Filing # Lot # Block # Lot Sq Ft CONSTRUCTON INFO: Total Building Sq Ft (NOT including basement) Total Garage Sq. Ft. # of Stories Bldg Ht # of Dwelling Units 1st Floor Sq Ft 1,702 2nd Floor Sq Ft 1,685 3rd Floor Sq Ft Unfinished Basement Sq Ft Finished Basement Sq Ft N/A # of Bedrooms # of Full Baths ¾ Baths ½ Baths 1 # Fireplaces ENERGY INFORMATION: (CHECK ONE) ComCheck ☐ UA (ResCheck) ☐ SPA (Simulated Performance Alternative) ☐ Prescriptive ☐ ERI (Energy Rating Index) ☐ Air Conditioning? YES ☐ NO ☐ City of Fort Collins Approved Stock Plan # List Option #s UTILITIES INFO: Gas ☐ Electric ☐ Electric Temp. Pedestal Yes ☐ No ☐ Electric Main Breaker Size (Residential Only): 150 amp or less ☐ 200 Amp ☐ Other ☐ ZONING INFO: (COMMERCIAL USE ONLY) Proposed Use: (i.e. medical, office, bank, retail, etc.) For Commercial remodels and tenant finishes, please answer the following questions: Is the remodel/tenant finishes for an existing or new tenant? (Please check one) Existing Tenant ☐ New Tenant ☐ If for a new tenant, is this the first tenant to occupy this space? Yes ☐ No ☐ If not for the initial tenant for this unit, what was the previous use of this tenant space? Are there any exterior building changes (including mechanical) associated with the work? Yes ☐ No ☐ If yes, please describe: COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES 281 N. College Ave. • Fort Collins, CO 80524 • Phone: 970.416.2740 • www.fcgov.com/building Toll Brothers TollCO1 LLC Stephen Schwarzer D-769 Kechter Farm 10 Inverness Dr. E Suite 125 Englewood CO 80112 303-708-0730 2 30' 4 3 1 1 N/A Crawl 746 2 14 4 6,900 Residential Sq Ft 3,387 Commercial Sq Ft N/A 3,387 B2002450 3/16/2020 JOBSITE SUPERVISOR CONTACT INFO: Name Phone SUBCONTRACTOR INFO: Electrical Mechanical Plumbing Framing Roofing Fireplace Solar Other ASBESTOS STATEMENT DISCLOSURE: In accordance with the State of Colorado Senate Bill 13-152, property owners, applying for a remodel permit, shall indicate their awareness about their property having been inspected for Asbestos Containing Materials (ACM's). ☐ I do not know if an asbestos inspection has been conducted on this property. ☐ An asbestos inspection has been conducted on this property on or about (enter date) ☐ An asbestos inspection has not been conducted on this property. Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements contained herein and City of Fort Collins ordinances and state laws regulating building construction. Applicant Signature Type or Print Name Phone # Email THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE Chadwick Electric Ft. Collins Htg & Air DEMA Plumbing NC Builders Advanced Roofing AMI Fireplace Brian Kelly 970-305-0474 Brittanny Markle 970-223-4704 ext. 0 bross@tollbrothers.com Value of Construction (materials and labor): $ Description of Work: Hayden Craftsman- 629-Gas Fireplace Brittanny Markle 353,527.70 Drawings depicting the scope of work Building Permit Application Plans must reflect current adopted codes and standards: Mechanical Design Form and Load Calcs www.fcgov.com/building/codes.php Homeowner Affidavit (homeowner builders only) Energy Code Compliance Form Construction Waste Management Plan Form All footing and foundation work (new or altered). Existing Drawings showing pre‐demo condition www.fcgov.com/historicpreservation Proposed Floor Plans with room labels and areas Exterior Elevations, Building Section, Details Townhomes only: Accessibility plan CRS 9‐5 WaterUtilitesEng@fcgov.com Sheer: wall bracing and method used, wind speed used, wind speed method, wind speed exposure. Grading plan may be required if impervious area on lot is greater than 350sf. Loads: Floor and roof loads used. Framing Plans: Floor, Roof, Girders and Headers https://www.fcgov.com/utilities/what‐we‐ do/stormwater/flooding/floodplain‐maps‐documents Connections and details. (provide stair details) Contact Zoning for questions on: Setbacks, easements, buildable area per lot, and short term rentals. Manual J,D,S (ACCA approved only) zoning@fcgov.com Outlets, lighting, panel, equipment. https://www.poudre‐fire.org/online‐services Show distance from new work to property lines, and adjacent structures on the same lot. Submit for full permit with an additional F&F set Alterations to, or Demolitions of buildings more than 50 years old will be reviewed for Historic Eligibility Building Permit Submittal Checklist: New Single Detached Family Homes, Duplexes, Townhomes, and Additions Incomplete or deferred submittals will not be accepted Required at the time of permit submittal ‐ Electronic submittal required. Required Drawings NA=Not Applicable NIS=Not in scope Additional Requirements (may require a separate submittal, or review process) Stamped & Signed Drawings by a Colorado Licensed Engineer/Architect are required for: Separate Demo Permit: Required for Full or Partial demolition of exterior elements. Separate Solar Permit: Required for all new solar Architectural Drawings: Historic Preservation Review Plan Check Fee (Payment by check only) Additional fee is required for an F&F permit. Structural Drawings: Are you building in a Floodplain? Zoning: 281 N College / (970) 416‐2745 Grading Applicant Name: Job Site Address: Phone: Email (Required): Mechanical Load Calcs (required for new forced air systems including new secondary systems for additions) Electrical Drawing Site Plan Fire Details Poudre Fire Authority: 102 Remington / (970)‐416‐2891 Townhomes and Duplexes only : Fire separation details and fire sprinkler systems under P2904 must be submitted for review. If using NFPA 13D, 13R or 13 Fire Suppression Systems, a separate submittal is required through the Poudre Fire Authority website. Optional Footing & Foundation Permit (new homes only, not allowed for additions) F&F Set: Structural Foundation Plans (stamped), Underground plumbing and electric (for townhomes only). Planning, Development & Transportation Services Community Development & Neighborhood Services 281 North College Avenue Fort Collins, CO 80524 970.416.2740 ✔ ✔ ✔ ✔ . . ✔ . X Select ✔ ✔ . . Brittanny Markle 2721 Heron's Nest Pl. 970-223-4704 bross@tollbrothers.com