HomeMy WebLinkAbout5926 Tilden St - Disclosures/Blower Door Test - 05/16/2019Envelope Leakage Test
Testing Company: Technician:
Name: Home Performance Solutions Name: Paul Trosclair
Address- Credentials: RFI
Email:
Building Information: Customer Information:
Project ID: 5926 Tilden St Name: RAH
Address: 5926 Tilden Street Address:
Fort Collins, Colorado 80528
Geo-Tag Data: Latitude: 40.504132
Longitude:-105.033204
Ti mestam p: 2019-05-16 16:51:11
Test Results: Measured Leakage: 2.99 ACH5O
Leakage Target: 3.00 ACH5O
Compliance with Leakage Target: Pass
Test ID:
Purpose of Test:
Measured CFM50:
Building Volume:
Flow Coefficient (C):
Correlation Coefficient:
Test Standard:
Test Characteristics:
Test Date and Time:
Test 1
IECC 12/15 Env. Leakage
2,133.8 (+/-1.8%)
42,866.0 ft3
154.1 (+/-13.0 %)
0.99856
ASTM E779 (single mode)
Pre Indoor Temp: 76 OF
Pre Outdoor Temp: 77 OF
Altitude: 4,893.0 ft
2019-05-16 16:53:27
3000
2000
E
U
N
01
Y 1000
a 900
0n 800
700
T' 600
m 500
mul
300 , -
4 5 6 7 8 910
Effective Leakage Area: 111.0 in
Enclosure Surface Area: 0.0 ft2
Exponent (n): 0.672 (+/- 0.036)
Test Mode: Depressurize
Post Indoor Temp: 76 OF
Post Outdoor Temp: 77 OF
Time Average Period: 10 seconds
20 30 40 50 6070
Building Pressure (Pa)
-48.2 Pascals to garage Passed
Envelope Leakage Test (Page 2)
Test Readings:
Target (Pa),
Bldg
Adj Bldg_(Pa),
Fan (Pa).
Flow (cfm),
Config
Baseline
0.0
-60.0
-61.0
-60.7
-166.4
2,301.2
Ring A
-54.0
-54.1
-53.9
-149.2
2,182.5
Ring A
-48.0
-48.5
-48.3
-128.4
2,028.1
Ring A
-42.0
-42.0
-41.8
-102.0
1,812.8
Ring A
-36.0
-37.1
-36.8
-83.7
1,645.9
Ring A
-30.0
-28.9
-28.6
-64.5
1,449.8
Ring A
-24.0
-25.3
-25.1
-50.5
1,286.8
Ring A
-18.0
-18.3
-18.0
-31.7
1,025.1
Ring A
Baseline
-0.5
Test Equipment:
Flow Device:
Model 3 Fan
Pressure Gauge:
DG700
Serial #: 29496
Calibration Date: 2019-04-01
Deviations from Standard:
• None