HomeMy WebLinkAbout4701 Strauss Cabin St - Correspondence/Building Inspection - 04/11/2019 (4)April 9, 2019 To: Project: Subject: A AMERICAN GYPSUM Shaw Construction b l�Jo ��lo0 3 l r) ��lG t -;?o�y6z !3 » o to� (0 3 Attn.: Jon Steinway g/ �2o 4, C/ G C/ The Wyatt 7 p 6 el 40 5 ' Fort Collins, CO �l iU 6(o American Gypsum wallboard installed backwards / To Whom It May Concern; I understand on the project listed above that the contractor has installed American Gypsum's 1/2" FireBloc Type C wallboard on the ceiling to ensure the specified fire rating (see below), with one piece of wallboard installed backwards - or with the back of the panel facing towards the floor. American Gyp§um's 1/2" FireBloc Type C wallboard UL classified panels like our 1/2" FireBloc Type C wallboard have a front and a back - with the front of the panel having tapers along the long edges to help with finishing using joint compound and tape. But the fire resistance of these UL classified panels is the same from either direction, and the inadvertent application of drywall with the back of the panel facing out - does not take away from the fire rating of a ceiling or wall assembly. Please let me know if you have any additional questions. Regards, 1 Bob Ek CSI, CDT Director of Systems Development and Technical Services American Gypsum Company 1-800-545-6302 ext. 5607 214-530-5607 - direct NOTE: This letter is valid only for the project listed above.