Loading...
HomeMy WebLinkAbout103 Frey Ave - Special Inspections/Engineering - 04/12/2019Gilbert Structural Engineering, LLC 3113 Meadowlark Ave Fort Collins, CO 80526 F, 970.377.3100 B�`��� April 12, 2019 Jim Keller 103 Frey Ave Fort Collins, CO Ref: Egress Window Opening Keller Remodel 103 Frey Ave Fort Collins, CO GSE Project Number: 19-007 Jim: SMOKE & CO ALARMS ARE REQUIRED PER CURRENT IRC / IBC ALL ELECTRICAL WORK SHALL BE IN COMPLIANCE WITH THE CURRENT N.E.C. As requested, I met with you at 103 Frey Ave on April 11, 2019 to observe and evaluate the structural support and adequacy of an egress window opening that is part of a remodel and in response to a Fort Collins Building Department inquiry. 103 Frey Ave is a single story, wood framed, single family residence that is over 75 years old. The new egress window is being installed in an existing basement window opening on the eastern side of the residence, and its support is carrying a portion of the existing main level floor framing. The opening is in a concrete block basement wall that has Code compliant width but will require increased depth. .:...... Only the opening width, applied load and A. structural support are relevant to this e�, ; inquiry, and all are unchanged in the = 02s§Ir1$ remodel. Based on•the International Residential Code (IRC) 2018, 40 psf main C•`1`j••, ; 'c�� , level live load, Vult (3sg), Risk Category 11,= 140 mph, Exp B, it is my professional opinion the window opening structure is safe and Code compliant. Sincerely, Glenn A Gilbert, PE