HomeMy WebLinkAbout2433 Spruce Creek Dr - Applications/Single Family New - 10/15/2018City of
II COMMUNITY DEVELOPMENT & NEIGHBORHOOD SERVICES
�t Collins 281 N. College Ave. • Fort Collins, CO 80524 • Phone: 970.416-2740
vvvvw fcgov corn/building
BUILDING PERMIT APPLICATION
APPLICATION NUMBER 11�) I V 1 APPLICATION DATE ol 15/1
Job Site Address 2433 Spruce Creek Dr Unit #
PROPERTY OWNER INFO: (All owner information is required — it is not optional) Phone # 720-977-3872
Last name Robbins First Name Amanda Middle
Street Address 4350 S. Monaco St. city Denver State CO Zip 80237
CONTRACTOR INFO: Company Name Richmond American Homes Contractor Phone # 720-977-3822
Lic Holder Name Tom Rigg City of Fort Collins License # D-342 Supervisor Cert #
Mailing Address same as owner City State Zip
LEGAL INFO:
Subdivision/PUD Mall Creek Crossing Filing # 1 Lot # 6 Block # 14 Lot Sq Ft 6312
CONSTRUCTION INFO: Total Building Sq Ft (not including basement) 3091 Total Garage Sq Ft 703
Residential Sq Ft 4375 Comm'I Sq Ft n/a # of Stories 2 Bldg Height 29.5' # Dwelling Units 1
1�' Floor Sq Ft 1392 2"d Floor Sq Ft 1699 31 Floor Sq Ft- Unfiished Bsmt Sq Ft 1284
Finished Bsmt Sq Ft - # of Bedrooms 4 # of Full Baths 2 3/4 Baths / Baths 1 # of Fireplaces 1
Air Conditioning: Yer✓ Non Energy info: ( Circle appropriate choice) 1. ComCheck 2. ResCheck w/Air Sealing11
3. ResCheck w/Blower Door ❑ 4. Simulated Performance Alternative 5. Prescriptive w/Air Sealing 6. Prescriptive w/ Blower Door
City of Fort Collins Stock Plan # SP02172 List appropriate option #s 2. 9, 12, 13.
UTILITIES INFO:
Water Tap Size 3/4" Sewer Tap Size 4" Metered: Yes 7No1_1 Temp. Pedestal Yes❑✓ No ❑
Type of Heat: FvJ Gas ❑Electric Electric Main Breaker Size (Residential only) W1150 Amp or Less ❑ 200 Amp DOther
Value of Construction (including labor, material & profit) $ 355,331
Description of Work:
D725, Elev A, Sunroonm, 3-Car, FP@FR, full SOG, A/C, Cov'd Patio@ Sun,
Contact Name & Phone # of JOESITE SUPERVISOR: Tom Rigg 970-381-8305
Subcontractor Info:
Electrical Courtesy Electric Mechanical Allied Heating & A/C Plumbing Confidence Plumbing
Framer Superior Image Construction Roofing D-7 Roofing Concrete J&C Foundations Fireplace Rio Grande Cc
Solar n/a Other Other Other
Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements
contained herein and City of Fort Collinfs ordinZand state laws regulating building construction.
Applicant Signature �LA4t.(1otiAr Print NameAmanda Robbins Phone 720-977-3872
Distribution: White — Office Yellow —Applicant Pink —WWW/Stormwater
THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE
City Of Updated 08/23/2017
F6rt Collins Planning, Development & Transportation Services
[� Community Development & Neighborhood Services -1,0910
2015 IRC —FORT COLLINS RESIDENTIAL ENERGY CODE COMPLIANCE FORM
FORM 1 — Use this form for single family houses, duplex, townhouses, or multi family up to 3 stories
Permit Number:
Address:2433 Spruce Creek Dr Lot 6/14 1
DIRECTIONS: Place a check (✓) next to Prescriptive, UA, SPA or ERI indicating the path chosen. An air
tightness Blower Door Test is required of all paths and must be equal to or less than 3 ACH50 (not applicable to
additions). Electrically heated buildings are required to use the prescriptive path (A).
(A) PRESCRIPTIVE compliance for house, 2015 IRC, section N1102.1,
Climate Zone 5
BUILDING ENVELOPE
INSULATION R-VALUE
ELECTRICALLY HEATED R-VALUE
Roof insulation in attic
R-49
R-49
Roof rafter insulation
R-30
R-30
Wood frame wall insulation
R-20 or R-13+R-5ci*
R-20 + R-5ci*
Crawl space wall
R-15ci*/19 or R-10ci*/13
w/ R-15 spray foam at rim joist
R-15ci*/19
Wood floor (over unconditioned space)
R-30
R-30
Walls below grade
R-15ci*/19 or R-10ci*/13
w/ R-15 spray foam at rim joist
R-15ci*/19
Slab on grade floor (insulation must
extend to top of slab)
R-10, 24" deep
R-10, 36" deep
Windows
U-0.32
U-0.30
*ci denotes Continuous Insulation (ie: insulation such as rigid foam board thaYs not broken by framing cavity)
(B) TOTAL UA ALTERNATIVE (REScheck), 2015 IRC, section N1102.1.5
Submit a passing UA calculation (REScheck) using 2015 IRC/IECC. The rating must be submitted at
time of application and must include address of residence, name of individual completing the rating
form, name and version of software tool (i.e. REScheck).
(C) SIMULATED PERFORMANCE ALTERNATIVE, 2015 IECC, section R405
An energy rating system (HERS rating) must be utilized using approved and current software tools
such as REM/Rate, Ekotrope, or EnergyGauge. A preliminary/projected rating passing 2015 IECC
must be submitted at time of application. Rating must include Address, Name of certified Energy
Rater, and version of software. Final ratings require a blower door test and must be submitted for
certificate of occuoancv.
(D) ENERGY RATING INDEX (ERI) COMPLIANCE ALTERNATIVE, 2015 IECC, section R406
An energy rating system must be utilized using approved and current software tools such as
REM/Rate, Ekotrope, or EnergyGauge. A preliminary/projected ERI analysis must be submitted and
shown to have an ERI index of less than or equal to 55. This is specific to climate zone 5 (found in
2015 IECC table R406.4).
Contractor or Applicant Name: Amanda Robbins for Richmond American Homes
Signature:
9/28/18
ne:(720 ) 977-3872
2015 IRC Residential Energy Code Compliance Form V2 08/23/2017