HomeMy WebLinkAbout2520 Owl Creek Dr - Disclosures/Blower Door Test - 03/04/2019BUILDING LEAKAGE TEST Date of Test: 3/4/2019 Customer: RAH Test Results 1. Airflow at 50 Pascals (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: Test File: 2520 Owl Creek dr bd Technician: Michael Broussard Project Number: Building Address: 2520 Owl Creek dr Fort Collins, CO 1684 CFM50 (+/- 0.9 %) 2.82 ACH50 92.6 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 180.0 (+/- 5.9 %) Exponent (n) = 0.572 (+/- 0.016) Correlation Coefficient = 0.99959 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/4/2019 Test File: 2520 Owl Creek dr bd Building Information Location Climate Information Volume 35834 Surface Area Floor Area Height # of Bedrooms # of Occupants Year of Construction 2019 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 37915-7 4/6/2017 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/4/2019 Test File: 2520 Owl Creek dr bd Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 62.0 28.0 5500.0 Data Points -Automated Test (TT 4.0.53.0) Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration 2.1 n/a n/a -57.7 -59.0 114.2 1915 1851 -0.0 Ring -52.0 -53.4 101.6 1809 1749 0.0 Ring A -45.2 -46.5 87.4 1681 1625 0.5 Ring A -39.6 -41.0 75.2 1562 1510 0.5 Ring A -33.7 -35.1 61.8 1420 1373 -0.2 Ring A -28.1 -29.4 49.4 1273 1230 -1.1 Ring A -22.1 -23.5 38.2 1123 1085 -0.7 Ring A -16.1 -17.4 27.9 963 931 1.0 Ring A 0.6 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi -Point Test - Test Parameters None No Text