HomeMy WebLinkAbout2527 Spruce Creek Dr - Disclosures/Final Energy - 08/10/2018��•
THIS HOME IS CERTIFIED TO MEET THE
2015 INTERNATIONAL ENERGY CONSERVATION CODE
0%
•:• FF r■I�` + \y: •. O i ■1 ,tf: . \..,. {{ � ■r .:: ,"•. ■. tt� rl .,c !, ■{t i !•• . e.• , i{{ 1 »� .isi • 1., . ^il■ , ■■r. . • ✓.'v {
�, t. E _.•. s,1 � � .....•.. _''{v{ •■• .. i�•{ .. ■r� \■,1 . . i {r�k'.�■!'•.1!{{!•u"�i�er
l4• ...:.. '_•-' ..a.�b •r1•.. � ■r l.■ . ... t _i'. ..__•.. J. � •. .•..{... ii._ 1. a.•a •• •••: i. •.
RESNET HERS@ Index Confirmed Rating: 53
Address:
2527 Spruce Creek dr, Fort Collins, CO 80528
Ceiling Flat:
R-49
Slab:
Conditioned Area:
3,657 House Type: Single family detached
Vaulted Ceiling:
NIA
Window Type:
Conditioned Volume:
31,524 Foundation: More than one type
Above Grade Walls:
R-21
Infiltration:
Bedrooms:
5
Foundation Walls:
R-19
Method:
Exposed Floor:
R-49
Rate:
R-0
U-Value: 0.28, SHGC: 0.4
BI ower-door tested
1574 CFM50 (3 ACH50)
Heating: Furnace • Natural Gas • 96.1 AFUE Percent Interior Lighting: 82% Range/Oven Fuel: Natural Gas
Cooling: Air Conditioner • Electric • 13 SEER Percent Garage Lighting: 0% Clothes Dryer Fuel: Electric
Water Heating: Water Heater • Natural Gas • 0.72 Energy Factor Refridgerator: 722 Clothes Dryer EF: 3.1
Duct Leakage to Outside: 22.0 Dishwasher Energy Factor: 0.78 Ceiling Fan (cfmlWatt): NIA
Ventilation System: Air Cycler: 120 cfm, 120 watts.
Programmable Thermostat: Heat=Yes; Cool=Yes HERS Provider & Rater
Home Performance Solutions - Provider
Principle: Mike Broussard
* ' Location: FORT COLLINS, CO
a@ • •. mike@hpsenergy.com
This home has been inspected and ' �.e,,. w�" Website: www.hpsenergy.com
performance tested in accordance 4with Phone Number: HPSENERGY.com
RESNET standards.
RESNET has developed the HERS Indexto indicate the comparative efficiencies of homes. to learn more, go to chttp7/unvw.resnet-us>. This information does not constitute any guarantee or representation of energy or
utility usage and costs or savings. Actual energy or utility usage and costs and savings will vary and depend on many factors that. include, without limitation, rates and charges oflocal utility companies, the type and
source of energy or utility, actual household energy and utility consumption, standard and optional Features selected, alterations and retrofits made, and climatic conditions. Refer to the Energy Wise Program home
disclosure addendum to the purchase agreement for additional information- The Home Energy Rating. Standard Disclosure for this home is available from the rating provider. Ekotrope 2.2.0.10-84. 2011-20W Ekotrope,
Boston, Massachusetts
IECC 2015 Performance Compliance
Property
2527 Spruce Creek dr
Fort Collins, CO 80528
RAH D250-6 C bR Final
2527 Spruce Creek dr
Design
Organization
Home Performance Solutif
720-985-8445 Inspection Status
Mike Broussard 2018-08-07
Rater ID (RTIN): 6104548
Builder RESNET Registered (Confirmed)
Richmond American Homes
Heating
Cooling
Water Heating
SubTota- I - Used fc— de-termine _compliance
Lights 8r Appliances
Onsite generation _
Total__
Annual Energy Cost
IECC 2015
As Designed
Performance
$610
$477
$115
$88
$184
$184
- _ _ . — - -- - -- --- -- 019 -- - -
_
$9 09
-- ---
$0
$0
405.3 402.4.1.2 402.5
Performance -based compliance Air Leakage Testing Area -weighted average fenestration
passes by 1TG% ® ® SHGC
402.5 404 Mandatory Checklist
Area -weighted average fenestration Lighting Equipment Efficiency
12
1
0
Design exceeds requirements for IECC 2015 Performance compliance by 17.6%.
Asa 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. if rating is Confirmed, I certify that the address referenced above has been
inspectedtlested and that the mandatory provisions of the IECC have been Installed to meet or exceed the intent of the IECC or vtill be verified as such by another party.
Name: Mike Broussard
Organization: Home Performance Solutions - Provider
Signature:' ;;W40
Digitally signed: 8/10/18 at 12:39 PM
Ekotrope RATER - Version 2.2.0.1984
IECC 2015 Performance compliance results calculated using Ekotrope s energy algodthm, which is a RESNET Accredited HERS Rating Tool.
Air Leakage Report
Property
2527 Spruce Creek dr
Fort Collins, CO 80528
RAHD250-B C bR Final
2527_Spruce Creek dr
Organization
Home Performance Solutic
720-985-8445
Mike Broussard
Builder
Richmond American Homes
Inspection Status
2018-08-07
Rater ID (RTIN): 6104548
RESNET Registered (Confirmed)
General Information
Conditioned Floor Area [sq. ft.]
3,657
Infiltration Volume [cu. ft.]
31,524
Number of Bedrooms
5
Air Leakage
Measured Infiltration
1574 CFM50 (3 ACH50)
ACH50 (Calculated)
3
ELA [sq. in] (Calculated)
86.6
ELA per 100 s.f. Shell Area (Calculated)
1.24
CFM50 (Calculated)
1574
Duct Leakage
System 1
Leakage to Outdoors [CFM @ 25 Pa]
22.0
Leakage to Outdoors [CFM25/ 100 s.f.]
0.6
Leakage to Outdoors [CFM25 / CFA]
0.006
Total Leakage Test Type
Rough -In, with Air Handler
Total Leakage [CFM @ 25 Pa]
128.0
Total Leakage [CFM25 / 100 s.f]
3.5
Total Leakage [CFM25 / CFA]
0.035
Mechanical Ventilation
Rate [CFM]
120.0
Hours per day
8.0
Fan Watts
120.0
Recovery Efficiency %
0.0
Runs at least once every 3 hrs?
true
Average Rate [CFM]
40.0
2010 ASHRAE 62.2 Req. Cont. Ventilation
81.6
2013 ASHRAE 62.2 Req. Cont. Ventilation
90.6
Ekotrope RATER - Version 2.2.0.1984
Existing
Homes
Reference
Home
Zero Energy
Home
Mom Em gy
Fort Collins, CO 80628
Rater: Mike Broussard
Registry ID: Unregistered
RESNET has developed the HERS Index to indicate the
comparative etficierims of homes. Typical resale hone is
based on the U.S. Department of Energy definition with a
HERS hdex of 130. Standard new hone is based on the
RESNET Reference Home defni8on with a HERS Index of
t0D (based on the 2006 International Energy Conservation
Code] This infonnaiion does not constitute any guarantee or
representation of energy or util3y usage and costs o savings.
Actual energy or unity usage and costs and savings wig vary
ano depend on many factors_ Refer to the Energy Wise
TItjS HomeProgram
home disclosure addendum to the purchase
5:3
agreement for additional information.
,��,•,' Home Performance Solutions - Provider
sre.-Home Performance Solutions -Provider
Fat Collins, CO
wwvr:hpsenergy.can
mike@hpseneigy.com
This home has been inspected and
tens Energy
performance tested in accordance
with RESNET standards