HomeMy WebLinkAbout1404 E Pitkin St - Correspondence/Rental Housing - 08/07/2018y �l
City of Planning, Development, and Transportation
Fort Collins Community Development &Neighborhood Services
281 N. College Ave. - PO Box 580
=
Fort Collins, CO 80522
970.416.2740
970.224.6134 - fax
fcgov.com/nbs
Rental Housing Inspection Results
8/7/2018
The Source Property Management
504 S. College Ave. Unit B
Fort Collins, CO 80524
RE A404 E. Pitkin, Fort Collins, Co 80524
Parcel Number: 8718305037
Dear Cesilie,
Records indicate you are the manager of the above referenced address.
This letter is to inform you that an inspection of this property was performed on 8/6/2018 the purpose of which
was to verify compliance with the Structure and Premises Condition Code of the City of Fort Collins, (Rental
Housing Code, 2006 International Property Maintenance Code, (IPMC)) as adopted by the City.
The inspection determined items that are not in compliance with the Rental Housing Code that need to be
corrected:
1. Need to repair or replace concrete going up to house. Causing trip hazard
2. Need to GFCI 2 outlets in garage, 3 outlets in laundry room and exterior
3. Replace water damaged base trim in bathroom off laundry
4. Need to spring load garage service door
5. Paint is chipping on ceiling of main bath need to re -paint. Recommend testing for lead before removing
paint chips.
6. Need to have screens on all windows
7. Hire pest control company to remove all hornet nests on or around house. And spray for spiders due to
cobwebs on house
8. Replace broken window in basement
9. Need to fix drainage away from house. Causing water issues inside basement windows.
10. Patch basement ceiling due to water damage.
11. Remove all plastic from room in basement that was converted to a grow and verify no mold issues exist.
If it does need to mitigate mold.
12. Install door on back sun room
13. Clean all gutters
14. Remove any tree limbs that are touching the house or gutters
15. Fix grading east side of garage causing settling on garage wall
16. Large crack in brick east side of house also same location in garage wall and concrete floor. Need
engineer to evaluate structural condition and make recommendations to correct. then have contractor
make repairs.
The above -mentioned items are considered General Maintenance items and must be repaired within (30) days of
the date of this notice.