HomeMy WebLinkAbout3032 Sykes Dr - Disclosures/Blower Door Test - 07/02/2018BUILDING LEAKAGE TEST GS ���er ices GS Services, LTD. 2000 S College Ave #308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 7/2/2018 Test File: Hartford Homes - 3032 Sykes Drive - Newton - BD1 Customer: Hartford Homes Technician: Nick Hiseler Project Number: Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Infiltration Estimates Building Address: 3032 Sykes Drive Fort Collins, CO 1504 CFM50 (+/- 2.3 %) 2.83 ACH50 82.7 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 34.9 ( +/- 17.2 %) Exponent (n) = 0.962 ( +/- 0.048 ) Correlation Coefficient = 0.99877 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Cr"�� GS'S�S BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 7/2/2018 Test File: Hartford Homes-3032 Sykes Drive-Newton-BD1 Building Infortnation Location Climate Infortnation Volume 31920 Ventilation Weather Factor 0.87 Surtace Area Energy Climate Factor 17.00 FloorArea , 3420 Heating Degree Days 6128 Height Cooling Degree Days 297 #of Bedrooms Design Winter Wind Speed 7.3 mph #of Occupants Design Summer Wind Speed 9.4 mph Year of Construction Design Winter Temp Diff 73 deg F Wind Shield M Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency% Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110� 19247 Default Micromanometer Energy Conservatory DG700 42530 1/22/2016 � �SY�S��� BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 7/2/2018 Test File: Hartford Homes-3032 Sykes Drive- Newton-BD1 Depressurization Test: Environmental Data indoor Temperature (A°F) Outdoor Temperature(A°F) Altitude(ft) 84.0 76.0 5000.0 Data Points Nominal BaselineAdjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Con£guration 2.7 n/a n/a -56.6 -57.9 71.8 1527 1677 -3.2 Ring A -50.3 -51.6 67.8 1420 1560 0.6 Ring A -45.9 -47.2 53.6 1325 1455 2.3 Ring A �1.2 -42.5 42.2 1179 1294 0.6 RingA -35.8 -37.1 31.2 1017 1117 -1.1 Ring A -29.2 -30.5 216.6 872 957 2.3 Ring B -24.1 -25.4 145.7 716 786 0.2 Ring B -16.7 -18.0 71.9 505 554 -1.5 Ring B -0.0 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test-Test Parameters None n p"� �^s��� BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 7/2/2018 Test File: Hartford Homes-3032 Sykes Drive-Newton-BD1 Comments House WRT Garage=-45.7 Pa