HomeMy WebLinkAbout3032 Sykes Dr - Disclosures/Blower Door Test - 07/02/2018BUILDING LEAKAGE TEST
GS ���er ices
GS Services, LTD.
2000 S College Ave #308
Fort Collins, CO 80525
Email: buildingperformance@gsservices.com Website: gsservices.com
Date of Test: 7/2/2018 Test File: Hartford Homes - 3032 Sykes Drive - Newton - BD1
Customer: Hartford Homes Technician: Nick Hiseler
Project Number:
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
4. Test Settings:
5. Accuracy Level
Infiltration Estimates
Building Address: 3032 Sykes Drive
Fort Collins, CO
1504 CFM50 (+/- 2.3 %)
2.83 ACH50
82.7 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 34.9 ( +/- 17.2 %)
Exponent (n) = 0.962 ( +/- 0.048 )
Correlation Coefficient = 0.99877
Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
Standard Level of Accuracy Test
1. Estimated Average Annual Infiltration Rate:
2. Estimated Design Infiltration Rate:
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
Cr"��
GS'S�S BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 7/2/2018 Test File: Hartford Homes-3032 Sykes Drive-Newton-BD1
Building Infortnation Location Climate Infortnation
Volume 31920 Ventilation Weather Factor 0.87
Surtace Area Energy Climate Factor 17.00
FloorArea , 3420 Heating Degree Days 6128
Height Cooling Degree Days 297
#of Bedrooms Design Winter Wind Speed 7.3 mph
#of Occupants Design Summer Wind Speed 9.4 mph
Year of Construction Design Winter Temp Diff 73 deg F
Wind Shield M Design Summer Temp Diff 15 deg F
Heating and Cooling Cost and Efficiency Information
Heating Fuel Gas
Heating Fuel Cost
Heating Efficiency%
Cooling Fuel Cost
Cooling SEER
Equipment Information
Type Manufacturer Model Serial Number Custom Calibration Date
Fan Energy Conservatory Model 3 (110� 19247 Default
Micromanometer Energy Conservatory DG700 42530 1/22/2016
�
�SY�S��� BUILDING LEAKAGE TEST Page 3 of 4
Date of Test: 7/2/2018 Test File: Hartford Homes-3032 Sykes Drive- Newton-BD1
Depressurization Test:
Environmental Data
indoor Temperature (A°F) Outdoor Temperature(A°F) Altitude(ft)
84.0 76.0 5000.0
Data Points
Nominal BaselineAdjusted Fan Nominal Adjusted
Building Pressure Building Pressure Pressure Flow Flow Fan
(Pa) (Pa) (Pa) (cfm) (cfm) % Error Con£guration
2.7 n/a n/a
-56.6 -57.9 71.8 1527 1677 -3.2 Ring A
-50.3 -51.6 67.8 1420 1560 0.6 Ring A
-45.9 -47.2 53.6 1325 1455 2.3 Ring A
�1.2 -42.5 42.2 1179 1294 0.6 RingA
-35.8 -37.1 31.2 1017 1117 -1.1 Ring A
-29.2 -30.5 216.6 872 957 2.3 Ring B
-24.1 -25.4 145.7 716 786 0.2 Ring B
-16.7 -18.0 71.9 505 554 -1.5 Ring B
-0.0 n/a n/a
Time Averaging Period: 0
Deviations from Standard RESNET Multi-Point Test-Test Parameters
None
n p"�
�^s��� BUILDING LEAKAGE TEST Page 4 of 4
Date of Test: 7/2/2018 Test File: Hartford Homes-3032 Sykes Drive-Newton-BD1
Comments
House WRT Garage=-45.7 Pa