Loading...
HomeMy WebLinkAbout2750 Illinois Dr - Disclosures/Blower Door Test - 06/25/2018 (4)Sye BUILDING LEAKAGE TEST GS Services LTD 2000 S College Ave Suite 308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 6/25/2018 Technician: Nick Hiseler Test File: Landmark Homes - 2750 Illinois Drive Unit :Project Number: BDexp Customer: Landmark Homes Building Address: 2750 Illinois Drive Unit 204 Fort Collins, CO Phone: Fax: Test Results at 50 Pascals: cfm50 Airflow 1175 (+/- 2.7 %) ACH50 cfm/ft2 (Floor Area) 0.8733 cfm/ftZ (Surface Area) 0.2722 Leakage Areas: 91.7 in (+/- 2.8 %) Canadian EgLA @ 10 Pa or 0.0212 in2/ft2Surface Area 41.6 in (+/- 4.8 %) LBL ELA @ 4 Pa or 0.0096 inZ/ftZ Surface Area Building Leakage Curve: Flow Coefficient (C) = 46.8 ( +/- 8.1 %) Exponent (n) = 0.824 ( +/- 0.025) Correlation Coefficient = 0.99931 Test Standard: E779-10 Test Mode: Depressurization 1 Building Leakage (cfm) 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) � BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/25/2018 Test File: Landmark Homes-2750 Illinois Drive Unit 204-Princeton-BDexp Building Information Volume(ft) Surtace Area: (ft2) 4316 Floor Area: (ft2) 1345 Height(ft) 10 Year of Construction Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 1/23/2017 Micromanometer Energy Conservatory DG700 19028-7 9/9/2014 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/25/2018 Test File: Landmark Homes-2750 Illinois Drive Unit 204-Princeton -BDexp Depressurization Test: Environmental Data Indoor Temperature(°F) Outdoor Temperature(°F) Altitude(ft) Pre-Test 76.0 81.0 Post-Test 76.0 81.0 Average 76.0 81.0 5000.0 Data Points Nominal BaselineAdjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.0 n/a n/a -59.5 -59.2 44.5 1210 1314 -2.6 Ring A -55.0 -54.6 40.8 1160 1260 -0.3 Ring A -50.5 -50.1 35.7 1087 1181 0.3 Ring A -45.0 -44.7 30.1 1000 1086 1.5 Ring A -38.7 -38.4 23.5 886 962 1.9 Ring A -11.6 -11.3 200.0 324 352 2.4 Ring C -11.2 -10.9 186.3 312 340 1.5 Ring C -11.1 -10.8 160.1 289 314 -5.5 Ring C -11.8 -11.5 197.9 322 350 0.1 Ring C -10.3 -9.9 159.4 288 313 1,0 Ring C -0.6 n/a n/a Deviations from Standard ASTM E779-10-Test Parameters - An interval between building pressures exceeds 10 Pa. - Pressurization test not included. . � BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/25/2018 Test File: Landmark Homes-2750 Illinois Drive Unit 204-Princeton- BDexp Comments None