Loading...
HomeMy WebLinkAbout2750 Illinois Dr - Special Inspections/Field Verification - 07/06/2018City of Fort Collins Multifamily Residential Test & Balance Note; This form is to be used when testing new Multi -family buildings only. Project address 2750 Illinois Drive Testing Authority Company Name GS Services FC ort oltins r� Building # Permit # Technician Nick Hiseler (Print name) Reference the "Residential Mechanical Systems Design Submittal' form or the stamped engineered mechanical design on plans for testing targets or ranges. numbers tested list all units tested; sampling not allowe (ie: units 101-208) 1011 102, 103, 104, 201-208 Note: all test results are required to use Air Density Correction Factor (ADCF) and are measured for volumetric flow (CFM 5,000� (AnCF = hncarl nn tnnl nititnrin (S nnnr) ,;. fe..,....­_ ♦L-,...,.I..,...n *Pass *Fail Test ElLocal Exhaust (spot ventilation) all bath fans operating at minimum 50 CFM intermittent or 20 CFM continuous. ❑ ❑ Kitchen Exhaust for Gas Cooking minimum 100 CFM intermittent or 25 CFM continuous ducted to the exterior test required). ❑Whole House Ventilation meets code minimum air flow & is within code minimum to +120% of design flow. + - 15% of design if balanced air flows stem ❑ ❑ Sub -structural floor exhaust (+/- 15% of design) if present. ❑Heating + Cooling Duct Leakage if anyductwork outside conditioned space (test required) leakage is 4% of sq foot of floor area or less per unit tested. ❑Heating + Cooling Equipment installed matches design, target cooling airflow within +/- 15% of design cooling air flow & system commissioned (outside of Nov -April). ❑ Room Airflow + Pressure Balance all rooms fall within -3 to +3 Pa pressure with relation to main area of house. ❑ ❑Combustion Safety test performed & appliance(s) meets BPI max spillage limit & draft pressure limit. If no natural draft appliances, test not required. it any item fails testing, provide notes on failure and plan to correct/fix failure. Testing Notes: I hereby attest the above mentioned address(s) has been tested per the City of Fort Collins Mechanical Svstems Performance I exmy prococois as oudinea in the ltesiaentiai New Construction Mechanical Systems Testing Guide. Nick Digitally signed by. Nick Hiseler N: ON o Nlck Hiseler email = Hiseler r'+'„�!salar�gsservicea.ammll c= up O = GB services 'Date 2018.07.0316:4210 4T00' Test Technician signature 3/22/18, 6/25/18, 6/27/18 Test date(s) Multifamily Residential Test -Balance Vl 06/13/2017 LandMark Homes The Flats at Rigden Farms �� 1? 1' 2750 Illinois Drive, Fort Collins, 80525 Floor Totals 2 4 0 2 2 2 20% = 2.4 #of unit types 6 Note: no C type units in this building