Loading...
HomeMy WebLinkAbout4863 Northern Lights Dr - Disclosures/Blower Door Test - 05/18/2018BUILDING LEAKAGE TEST urm GS Services, LTD. w stservi 2000 S College Ave #308 s. --•�"` Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com B1pfi�' 6 4.) 4 Date of Test: 5/18/2018 Test File: Landmark Homes - 4863 Northern Lights Drive Unit A - Chenin Blan Customer: Hartford Homes Technician: Nick Hiseler Project Number: Building Address: 4863 Northem Lights Drive UnitA Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 1089 CFM50 (+/- 5.0 %) (50 Pa = 0.2 w.c.) 2.67 ACH50 2. Leakage Area: 59.9 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 60.0 (+/- 33.0 %) Exponent (n) = 0.741 ( +/- 0.093 ) Correlation Coefficient = 0.99222 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: GS emces i- --- BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/18/2018 Test File: Landmark Homes - 4863 Northern Lights Drive Unit A - Chenin Blanc - BD1 Building Information Volume 24476 Surface Area Floor Area 2532 Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 - Micromanometer Energy Conservatory DG700 19028 9/9/2014 GScSemces 1-- BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/18/201'8 Test File: Landmark Homes - 4863 Northern Lights Drive Unit A - Chenin Blanc - BD1 Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) " 79.0 84.0 5000.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration 0.8 n/a n/a -55.7 -56.5 36.3 1095 1171 -1.8 Ring A -52.0 -52.8 33.6 1055 1127 -0.6 Ring A -45.3 -46.1 27.1 949 1015 -1.0 Ring A -36.2 -37.0 192.6 822 879 1.0 Ring B -32.3 -33.1 165.3 762 815 1.7 Ring B -25.3 -26.1 132.4 683 730 8.4 Ring B -23.4 -24.2 92.8 573 612 -3.7 Ring B -16.9 -17.7 58.5 455 487 -3.5 Ring B 0.8 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi -Point Test - Test Parameters IZINS Ta GHendces �__ --- BUILDING LEAKAGE TEST Page 4 of 4 Comments Detached Garage