HomeMy WebLinkAbout2150 Lager St - Special Inspections/Engineering - 05/07/2018CTLITHOMPSON April 30, 2018 �fg6 ©31 S'a��v Hartford Homes at Timbervine, LLC 4801 Goodman Street Timnath, Colorado Mr. Zac Rothenbuehler Subject: Avery Contemporary Model Front Porch Post Timbervine Subdivision, Ft. Collins, CO. CTL Thompson Project Number: FC06508 Mr. Rothenbuehler, Our stamped drawings for all Avery Contemporary plans show a column under the porch roof beam. There is no callout for this column. Per our General Notes, page S3 note 7, all columns not called out on plans are to be (3) 2x to match the wall thickness. In this case (3) 2x4 would be used. In lieu of the 2x column a 4x4 engineered wood column may be used with the appropriate base and beam attachments per the plans. This option is valid for all previously stamped Avery Contemporary models. Thank you for selecting CTL Thompson for your engineering needs. When we can be of additional service, please contact our office. Very truly yours, CTL Thompson, INC. Scott Hargrove, PE Project Manager 04/3 0/ 18 400 North Link Lane I Fort Collins, Colorado 80524 Telephone:970-206-9455 Fax:970-206-9441 CTLITHOMPSON March 22, 2018 Hartford Homes, LLC 4801 Goodman Street 6 Timnath, Colorado Mr. Zac Rothenbuehler Subject: Front Porch Post Cap Installation Timbervine Subdivision Fort Collins, CO CTL Thompson Project Numbers: FC06508 Mr. Rothenbuehler, Per your emails from March 21, 2018 the Simpson BC -Series Post Caps, used to connect the front porch columns to the roof support beams, are not being installed per the manufacturer's specifications. The use of (4) ply beams instead of the (2) ply specified on the plans makes the installation of the post cap differ from the Simpson specifications. The revised installation involves bending the interior beam flange 90 degrees and nailing it into the bottom of the supported beam. This reduces the uplift capacity of the connector by approximately 50 percent. The resulting connection is sufficient for the front porches on the Timbervine products. We do recommend that the cap be installed per manufacturer specifications whenever possible. Thank you for selecting CTL Thompson for your engineering needs. When we can be of additional service, please contact our office. Very truly yours, CTL Thompson, INC. Scott Hargrove, PE Project Manager 03/22/18 400 North Link Lane I Fort Collins, Colorado 80524 Telephone:970-206-9455 Fax:970-206-9441