HomeMy WebLinkAbout2251 Yearling Dr - Disclosures/Final Energy - 01/25/2017REScheck Software Version 4.6.3
C�J(
Compliance Certificate
Project Bucking Horse Filing Four (Building Q
Energy Code:
2012 IECC
Location:
Fort Collins, Colorado
Construction Type:
Single-family
Project Type:
New Construction
Orientation:
Unspecified
Conditioned Floor Area.
2,388 ft2
Climate Zone:
5 (6368 HDD)
Permit Date -
Permit Number:
Construction Site:
Owner/Agent:
Designer/Contractor:
Seilisimo, Inc.
Ian Shuff alm2s
Jeremy Babilorna
Fort Collins, CO 80525
712 Whalers Way
SRB Consulting Engineering, LLC
SuiteB-100
37127 Cullsion Ridge Road
Fort Collins, CO 80525
Windsor, CO 80550
970.223.1820
970.686 1004
ishuff@alm2s com
jeremyb@srbllc net
Mechanical Equipment
Forced Hot Air 80 AFUE
Electric Central Air 13 SEER
Project Title: Bucking Horse Filing Four (Building C) Report date: 01/25/17
Data filename: L.\SRB Drawings\SRB DRAWINGS - 2016\Bucking Horse Apartments - (16039)\Design Pagel of 5
Loads\Bucking Horse (Building C) - Mech.rck
cREScheck Software Version 4.6.3
l�(J Inspection Checklist
Energy Code: 2012 IECC
Requirements: 89.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
section
_
"Pre-Irisjiectlon/Plan Review
Plans Verified
Valuer<<
Field Verified
Value
Complies?
Comments/Assurr+ptions
_.:.
....
,c 3
103.1,
!Construction drawings and
❑Complies ; Requirement will be met
103.2,
documentation demonstrate
[]Does Not
403.7
; energy code compliance for
[]Not ObservableSystems
[PR311
'lighting and mechanical systems
serving multiple
mi
n
❑Not Applicable '
'
;dwelling units must demonstrate
compliance with the IECC
;Commercial Provisions,
302.1,
Heating and cooling equipment is
; Heating:
;Heating:
;❑Complies ;Requirement will be met.
40T
sized per ACCA Manual S based
Btu/hr
Btu/hr
:0Does Not
[PR212
on loads calculated per ACCA
; Cooling:Cooling:
;❑Not Observable
Manual J or other methods
BtuJhr
; Btu/hr
;❑Not Applicable ;
approved by the code official.
;
Additional Comments/Assumptions:
1 I High Impact (Tier 1) J, -, Medium impact (Tier 2) 13 1 Low impact (Tier 3)
Project Title: Bucking Horse Filing Four (Building C) Report date: 01/25/17
Data filename: L:\SRB Drawings\SRB DRAWINGS - 2016\Bucking Horse Apartments - (16039)\Design Page 2 of 5
Loads\Bucking Horse (Building C) - Mech.rck
Section
F`oundation-lnspection Complies?" � Comments/Assumptions`
4 - 3.6 Snow- and ice -melting system controls ;❑Complies :Requirement will be met.
installed. T❑Does Not
❑Not Observable
!,[]Not Applicable
Additional Comments/Assumptions:
i
111 High Impact (Tier 1) i524Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Bucking Horse Filing Four (Building C) Report date: O1/25/17
Data filename: L:\SRB Drawings\SRB DRAWINGS - 2016\Bucking Horse Apartments - (16039)\Design Page 3 of 5
Loads\Bucking Horse (Building C) - Mech.rck
Section
#
Framing / Rough -in Inspection
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Re .IO',�,
s
..ax ° wr r
4052
:All ducts in unconditioned spaces ; R-_
; R- ;❑Complies
;
[FR25]'
l or outside the building envelope
;❑Does Not
;are insulated to aR-6.
❑Not Observable ;
❑Not Applicable
403.2.2
;All joints and seams of air ducts,
❑Complies ; Requirement will be met
[FR13]'
!air handlers, and filter boxes areNile
❑Does Not
:sealed.❑Not
Observable❑Not
Applicable
403.2.3
Building cavities are not used as❑Complies
; Requirement will be met.
[FR15]3
ducts or plenums.
[]Does Not
❑Not Observable ;
❑Not Applicable
piping conveying Fluids R-_
R-_ ;❑Complies ; Requirement will be met
above 105 of or chilled fluids
:❑Does Not
M,3HVAC
below 55 OF are insulated to aR-
;❑Not Observable r
3.
❑Not Applicable
403.3.1
:Protection of insulation on HVAC
❑Complies ;Requirement will be met.
[FR24]'
; piping.
❑Does Not
,
❑Not Observable
❑Not Applicable
water pipes are insulated to ; R-
; R-;❑Complies ; Requirement will be met.
>R-3
,❑Does Not
W63j§2Hot
;❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 2jl Medium impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Bucking Horse Filing Four (Building C) Report date: 01/25/17
Data filename: L:\SRB Drawings\SRB DRAWINGS - 2016\Bucking Horse Apartments - (16039)\Design Page 4 of 5
Loads\Bucking Horse (Building C) - Mech.rck
IVA
I
SOttlom,
Final
lzins V Hfie�
Field VVerifiedd"'
#
Inspection Provisions
I
I Value
Value
Complies?
Comments/Assumptions
Re .ID
403.2.2
Duct tightness test result of <=4
I cfm/100 cfm/100
:E]Complies !Requirement will be met
[F14]1
cfm/100 ft2 across the system or ft2 ft2
ElDoes Not
0
<=3 cfm/100 ft2 without air
UNot Observable
handier @ 25 Pa For rough -in
:tests, verification may need to
:E]Not Applicable
:occur during Framing Inspection.
403.2 21 ;,Air handier leakage designated
OComplies I Requirement will be met.
[F124]1
:by manufacturer at <=2% of
E]Does Not
:design air flow.
C:]Not Observable
E]Not Applicable
4036
, Heating and cooling equipment
ElComplies
[F15]1
:type and capacity as per plans.
E]Does Not
[]Not Observable
ONot Applicable
0 1
Programmable thermostats
ElComplies :Requirement will be met
Fill 2
[ ]2
installed on forced air furnaces.
a
ODoes Not
Affl 1%
E]Not Observable
0Not Applicable
7a4, 3
Heat pump thermostat installed
OComplies :Requirement will be met.
F01
on heat pumps.
E]Does Not
[]Not Observable 1
0Not Applicable :
�a4,03
ffl
Circulating service hot water
OComplies :Requirement will be met.
I'll �21
systems have automatic or
E)Does Not
accessible manual controls.
[]Not Observable
ONot Applicable
3.5.1
All mechanical ventilation system
OComplies :Requirement will be met.
12 J
fans not part of tested and listed
0Does Not
HVAC equipment meet efficacy
E]Not Observable
and air flow limits
ONot Applicable
404.1
75% of lamps in permanent
ElComplies 1 Requirement will be met
[F1611
:fixtures or 75% of permanent
E]Does Not
(a
:fixtures have high efficacy lamps. I
[]Not Observable 1
:Does not apply to low -voltage
lighting.
ONot Applicable
4041,1
Fuel gas lighting systems have
OComplies Requirement will be met.
[F123]3
no continuous pilot light.
E]Does Not
ONot Observable
E]Not Applicable
3033
manufacturer manuals for
ElComplies Requirement will be met.
[FI18]3
mechanical and water heating
E]Does Not
systems have been provided.
11M
Not Observable
[]ONot
Applicable
Additional Commients/Assumptionsi
11 High Impact (Tier 1) 1?,2x] Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Bucking Horse Filing Four (Building Report date: 01/25/17
Data filename: L:\SRB Drawings\SRB DRAWINGS- 2016\Bucking Horse Apartments - (16039)\Design Page 5 of 5
Loads\Bucking Horse (Building Q - Mech.rck
No Text