HomeMy WebLinkAbout2251 Yearling Dr - Disclosures/Final Energy - 01/25/2017REScheck Software Version 4.6.3 C�J( Compliance Certificate Project Bucking Horse Filing Four (Building Q Energy Code: 2012 IECC Location: Fort Collins, Colorado Construction Type: Single-family Project Type: New Construction Orientation: Unspecified Conditioned Floor Area. 2,388 ft2 Climate Zone: 5 (6368 HDD) Permit Date - Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Seilisimo, Inc. Ian Shuff alm2s Jeremy Babilorna Fort Collins, CO 80525 712 Whalers Way SRB Consulting Engineering, LLC SuiteB-100 37127 Cullsion Ridge Road Fort Collins, CO 80525 Windsor, CO 80550 970.223.1820 970.686 1004 ishuff@alm2s com jeremyb@srbllc net Mechanical Equipment Forced Hot Air 80 AFUE Electric Central Air 13 SEER Project Title: Bucking Horse Filing Four (Building C) Report date: 01/25/17 Data filename: L.\SRB Drawings\SRB DRAWINGS - 2016\Bucking Horse Apartments - (16039)\Design Pagel of 5 Loads\Bucking Horse (Building C) - Mech.rck cREScheck Software Version 4.6.3 l�(J Inspection Checklist Energy Code: 2012 IECC Requirements: 89.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section _ "Pre-Irisjiectlon/Plan Review Plans Verified Valuer<< Field Verified Value Complies? Comments/Assurr+ptions _.:. .... ,c 3 103.1, !Construction drawings and ❑Complies ; Requirement will be met 103.2, documentation demonstrate []Does Not 403.7 ; energy code compliance for []Not ObservableSystems [PR311 'lighting and mechanical systems serving multiple mi n ❑Not Applicable ' ' ;dwelling units must demonstrate compliance with the IECC ;Commercial Provisions, 302.1, Heating and cooling equipment is ; Heating: ;Heating: ;❑Complies ;Requirement will be met. 40T sized per ACCA Manual S based Btu/hr Btu/hr :0Does Not [PR212 on loads calculated per ACCA ; Cooling:Cooling: ;❑Not Observable Manual J or other methods BtuJhr ; Btu/hr ;❑Not Applicable ; approved by the code official. ; Additional Comments/Assumptions: 1 I High Impact (Tier 1) J, -, Medium impact (Tier 2) 13 1 Low impact (Tier 3) Project Title: Bucking Horse Filing Four (Building C) Report date: 01/25/17 Data filename: L:\SRB Drawings\SRB DRAWINGS - 2016\Bucking Horse Apartments - (16039)\Design Page 2 of 5 Loads\Bucking Horse (Building C) - Mech.rck Section F`oundation-lnspection Complies?" � Comments/Assumptions` 4 - 3.6 Snow- and ice -melting system controls ;❑Complies :Requirement will be met. installed. T❑Does Not ❑Not Observable !,[]Not Applicable Additional Comments/Assumptions: i 111 High Impact (Tier 1) i524Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Bucking Horse Filing Four (Building C) Report date: O1/25/17 Data filename: L:\SRB Drawings\SRB DRAWINGS - 2016\Bucking Horse Apartments - (16039)\Design Page 3 of 5 Loads\Bucking Horse (Building C) - Mech.rck Section # Framing / Rough -in Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Re .IO',�, s ..ax ° wr r 4052 :All ducts in unconditioned spaces ; R-_ ; R- ;❑Complies ; [FR25]' l or outside the building envelope ;❑Does Not ;are insulated to aR-6. ❑Not Observable ; ❑Not Applicable 403.2.2 ;All joints and seams of air ducts, ❑Complies ; Requirement will be met [FR13]' !air handlers, and filter boxes areNile ❑Does Not :sealed.❑Not Observable❑Not Applicable 403.2.3 Building cavities are not used as❑Complies ; Requirement will be met. [FR15]3 ducts or plenums. []Does Not ❑Not Observable ; ❑Not Applicable piping conveying Fluids R-_ R-_ ;❑Complies ; Requirement will be met above 105 of or chilled fluids :❑Does Not M,3HVAC below 55 OF are insulated to aR- ;❑Not Observable r 3. ❑Not Applicable 403.3.1 :Protection of insulation on HVAC ❑Complies ;Requirement will be met. [FR24]' ; piping. ❑Does Not , ❑Not Observable ❑Not Applicable water pipes are insulated to ; R- ; R-;❑Complies ; Requirement will be met. >R-3 ,❑Does Not W63j§2Hot ;❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 2jl Medium impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Bucking Horse Filing Four (Building C) Report date: 01/25/17 Data filename: L:\SRB Drawings\SRB DRAWINGS - 2016\Bucking Horse Apartments - (16039)\Design Page 4 of 5 Loads\Bucking Horse (Building C) - Mech.rck IVA I SOttlom, Final lzins V Hfie� Field VVerifiedd"' # Inspection Provisions I I Value Value Complies? Comments/Assumptions Re .ID 403.2.2 Duct tightness test result of <=4 I cfm/100 cfm/100 :E]Complies !Requirement will be met [F14]1 cfm/100 ft2 across the system or ft2 ft2 ElDoes Not 0 <=3 cfm/100 ft2 without air UNot Observable handier @ 25 Pa For rough -in :tests, verification may need to :E]Not Applicable :occur during Framing Inspection. 403.2 21 ;,Air handier leakage designated OComplies I Requirement will be met. [F124]1 :by manufacturer at <=2% of E]Does Not :design air flow. C:]Not Observable E]Not Applicable 4036 , Heating and cooling equipment ElComplies [F15]1 :type and capacity as per plans. E]Does Not []Not Observable ONot Applicable 0 1 Programmable thermostats ElComplies :Requirement will be met Fill 2 [ ]2 installed on forced air furnaces. a ODoes Not Affl 1% E]Not Observable 0Not Applicable 7a4, 3 Heat pump thermostat installed OComplies :Requirement will be met. F01 on heat pumps. E]Does Not []Not Observable 1 0Not Applicable : �a4,03 ffl Circulating service hot water OComplies :Requirement will be met. I'll �21 systems have automatic or E)Does Not accessible manual controls. []Not Observable ONot Applicable 3.5.1 All mechanical ventilation system OComplies :Requirement will be met. 12 J fans not part of tested and listed 0Does Not HVAC equipment meet efficacy E]Not Observable and air flow limits ONot Applicable 404.1 75% of lamps in permanent ElComplies 1 Requirement will be met [F1611 :fixtures or 75% of permanent E]Does Not (a :fixtures have high efficacy lamps. I []Not Observable 1 :Does not apply to low -voltage lighting. ONot Applicable 4041,1 Fuel gas lighting systems have OComplies Requirement will be met. [F123]3 no continuous pilot light. E]Does Not ONot Observable E]Not Applicable 3033 manufacturer manuals for ElComplies Requirement will be met. [FI18]3 mechanical and water heating E]Does Not systems have been provided. 11M Not Observable []ONot Applicable Additional Commients/Assumptionsi 11 High Impact (Tier 1) 1?,2x] Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Bucking Horse Filing Four (Building Report date: 01/25/17 Data filename: L:\SRB Drawings\SRB DRAWINGS- 2016\Bucking Horse Apartments - (16039)\Design Page 5 of 5 Loads\Bucking Horse (Building Q - Mech.rck No Text