Loading...
HomeMy WebLinkAbout407 S Grant St - Special Inspections/Engineering - 09/22/2017w[aMMs M G155OC2GlTESy STRUCTURAL ENGINEER P�1fli118 1.32 M September 22, 2017 Jim Liebel Re: Framing/ 407 s. drant Ave Fort Collins, Colorado Project No. 217162 Gentlemen: On September 19th, 2017, a representative of Weeks & Associates observed the header installment over the new sliding door at the rear of the residence at the referenced site. Observation indicate the header and associated framing is in substantial accordance with the recommendations for the project by Weeks & Associates If we can be of further assistance please contact us. Sincerely, �Pp0 REGIS Weeks R 87� P VV C7 .p 23012 G ry G. We' s P,E. •' °, S uctural Er�figjnt }e L • ,� fvn 4730 South College Ave, Suite 201, Fort Collins, CO 80525 Phone (970) 225 2422 - Fax (970) 225.2622 wssFis S G-1550C2G1Tl2S STRUCTURAL ENGINEERS August 17, 2017 Jim Liebl 2 1 MAR 18 1.32Pm Re: 407 South Grant Street Fort Collins, Colorado Project No. 217162 As requested I have reviewed the framing requirements for a new 12' wide sliding door to be installed in the west wall of the house. DISCUSSION The sliding door is to be installed in the west wall of the one-story portion at the west side of the house. The west wall at the location of the door supports a shed roof that spans approximately 16 feet. I , RECOMMENDATIONS Based on the proposed opening and design roof loads of 30 psf snow and 20 psf dead load it is recommended a (2)-1 3/4 x 9 1/2" LVL header be used. 2-2x4 trimmers and 3-2x4 king studs should be provided each end. Solid block under the trimmers to the foundation below. If I can be of further assistance please contact me. Sincerely, W Weeks 8� A e �. G. W co;'QPy FF� :moo C'S N 23012 GAy G. W Ins, P.E. St ctural eer •' �� r� f- a 4730 South College Ave, Suite 201, Fort Collins, CO 80525 Phone (970) 225 2422 - Fax (970) 225.2622