HomeMy WebLinkAbout2321 Spruce Creek Dr - Disclosures/Blower Door Test - 01/29/2018BUILDING LEAKAGE TEST 6 Date of Test 1/29/18 Customer Richmond American CO 1 7 0 P 3 0 0 Test File. 2321 Spruce creek dr Technician Michael Broussard Project Number Building Address- 2321 Spruce Creek dr Fort Collins, CO Test Results 1 Airflow at 50 Pascals 1732 CFM50 (+/- 7 8 %) (50Pa=02wc) -290ACH50 2 Leakage Areas 182.6 in2 ( +/- 29.4 %) Canadian EgLA @ 10 Pa 98 4 m2 (+/- 49 2 %) LBL ELA @ 4 Pa 3 Building Leakage Curve Flow Coefficient (C) = 143 5 ( +/- 79 3 %) Exponent (n) = 0 637 ( +/- 0.218 ) Correlation Coefficient = 0 82507 4 Test Settings Test Standard CGSB Test Mode Depressurization Infiltration Estimates 1 Estimated Average Annual Infiltration Rate 2 Estimated Design Infiltration Rate: Cost Estimates 1 Estimated Cost of Air Leakage for Heating 2 Estimated Cost of Air Leakage for Cooling* BUILDING LEAKAGE TEST Page 2 of 4 Date of Test 1/29/18 Test Fde 2321 Spruce creek dr � Building Information � � � � � Lo�ya�i�n C imate Information Volume 35834 Ventilation Weather Factor 0.87 SurfaceArea Energy Climate Factor 17.00 FloorArea Heating Degree Days 6020 Height Cooling Degree Days 287 #of Bedrooms Design Winter Wind Speed 9.0 mph #of Occupants Design Summer Wind Speed 7.0 mph Year of Construction Design Winter Temp Diff 69 deg F Wind Shield M Design Summer Temp Diff 16 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency% Coohng Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - , BUILDING LEAKAGE TEST Page 3 of 4 Date of Test. 1/29/18 Test Fde 2321 Spruce creek dr �� , Depressurization Test: p�, � � �� °� � � Q Environmental Data �� C�. Indoor Temperature(°F) Outdoor Temperature(°F) 75 0 18.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan • (Pa) (Pa) (Pa) (cfm) (cfm) °/a Error Configuration 0 9 n/a n/a -49 1 -48 4 97.7 1776 1678 -1 1 Ring A -45 0 -44 4 82 3 1633 1543 -3 9 Ring A -39 0 -38 4 67.5 1482 1401 -4 3 Ring A -33 7 -33 0 87 0 1678 1586 19.2 Ring A -29.2 -28 5 39 9 1146 1084 -10.6 Ring A -24 2 -23 6 31 5 1022 966 -10.0 Ring A -2 2 n/a n/a Deviations from Standard CGSB -Test Parameters - Correlation coefficient(0.825}outside of acceptable limits. - % Error for one or more of the data test points is greater than 6%. - Test data was not collected at all 8 recommended target building pressures. BUILDING LEAKAGE TEST Page 4 of 4 • Date of Test 1/29/18 Test Fde 2321 Spruce creek dr �' Comments -48 92pascals to garage Passed � � � � � � � �