,/ / A�lt"cr,/the F ict B isement Fimsh Requucmeents {
Address '`io� �1 �"'!s t f U�'l « Pcrnnt NoP " 7 n " 71
T
With the issu inee of this "After the Fact" permit, the City males no statement about, Assumes no
responsibility for, nor inspects any constniction component behind the drywall The following
items are required and will be verified by the City building inspector
C Llech is it outlet sp ►,Ling, outlets shall be cost )lied within 6 feet of doorw'iy edges ind
within 12 feet of e )ch other outlet as me isured along the floor perimeter
• T unpti resist uit outlets, all new outlets within the scope of work identified on the
permit, shall be tamper resistant
o kre I iult pi oteeted, all new outlets within the scope of work identified on the permit,
shall be pi otected by an Arc Fault outlet or bre-iker
• Ground t uilt circuit mterruptu, all new outlets instilled in b ithrooms or serving
counter sp ice with wet sml.s shall be GFCI protected
• Snuil.c it irms, are required within each bedroom and outside the sleeping area,
Ihioit ghoul tht home, may be electrically connected of battery Opel'Ited
o C irbon monoxide al irms, homes with attached gaviges or gas fired equipment, one
alarm is required outside of e ich sleeping area
0 Gxh iust f in, bathrooms without an openable window shall be provided with an exhaust
fan ducted to the outside
e Gu irdrails ind handrails, stairs shall be provided with guardrails where needed and all
stairs of 4 or more risers shall be provided with one handmil extending the entire length
of the Stairway
C St cirw iy landings, all stairs shall have a clear 36 inch by 36 inch landing at the bottom
of the st iir
• Stair" ay protection, stairways shall be enclosed or shall be protected on the back
(underside) of the stringers with mimmum of/2 mch sheetrock
• Closet lighting, light fixtures installed m closets shall be a minimum of 12 inches from
shelf edges
• Egress windows, basements shall have at least one egress window which provides 5
square feet of clear openable area or door leading directly to the outside, additionally all
bedrooms shall have an egress window or door leading directly to the outside
After the Fact Basement Finish Requirements
® Egress window wells, newly installed egress windows shall be provided with a window
well which extends a minimum of 36 inches outward from the exterior wall Window
wells deeper than 44 inches shall have a permanent ladder installed in the window well
o Mechanical equipment, mechanical closets containing fuel burning appliances shall not
be accessed through a bedroom or bathroom
o Mechanical equipment access, mechanical rooms and closets shall have access doors
large' enough too remove the largest piece of equipment Removal of one piece of
equipment shall not require the removal of another piece of equipment
o Mechanical air path, forced air mechanical systems shall be provided with a return air
path back to the equipment The return air path shall be by ductwork or transfer grills and
openings with limited obstructions
o Gas burning fireplaces shall be directly vented to the outside
o Gas piping, all new gas piping shall be under a 10 pound air test during the City
inspection
o Wood burning appliance, all wood burning appliances shall require a separate permit
and inspection
a Plumbing, all plumbing fixtures shall be constructed of approved materials, with smooth,
impervious surfaces
o All plumbing fixtures shall be provided with potable water, hot and cold as required by
the fixture
o Gray water systems are required to be approved prior to installation and require a
separate permit and inspection
TreeV 1 LuckAu- -/ VAM,�,
Owner's Name Print
Updated Oct/20 ] 5
Owner's signature