HomeMy WebLinkAbout750 Jerome St - Disclosures/Blower Door Test - 03/31/2017Qnergyliogic
analysis. Insight. answers.
www.nrglogic.com
Date of Test: 3/31/2017
Customer: Philgreen
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
4. Test Settings:
5. Accuracy Level
BUILDING LEAKAGE TEST
Test File: Multi Point Tectite 750 unit 6 (A)
Technician: Trevor Donnelly- EnergyLogic
Project Number: 44695
Building Address: 750 Jerome St Unit 4 (A)
Fort Collins, CO 80524
504 CFM50 (+/- 0.6 %)
2.32 ACH50
27.7 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 15.3 (+/ 10.5 %)
Exponent (n) = 0.893 ( +/- 0.028 )
Correlation Coefficient = 0.99952
Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate:
2. Estimated Design Infiltration Rate:
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
QnergyLogic
www.mglogic.com BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 3/31/2017 Test File: Multi Point Tectite 750 unit 6 (A)
Building Information
Volume
13046
Surface Area
Floor Area
1299
Height
# of Bedrooms
# of Occupants
Year of Construction
2016
Wind Shield
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
Location Climate Information
Ventilation Weather Factor
0.87
Energy Climate Factor
17.00
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
7.3 mph
Design Summer Wind Speed
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
15 deg F
Equipment Information
Type
Manufacturer
Model
Serial Number
Custom Calibration Date
Fan
Energy Conservatory
Model 3 (110V)
Default
Micromanometer
Energy Conservatory
DG700
7170-5
10/9/2008
QnergyLogic
www.nrglogic.com BUILDING LEAKAGE TEST Page 4 of 4
Date of Test: 3/31/2017 Test File: Multi Point Tectite 750 unit 6 (A)
Comments
Connection to:
Garage: no attached garage
Mechanicals: -50 Pa