HomeMy WebLinkAbout3824 Manhattan Ave - Disclosures/Insulation - 01/27/2017Builders Statement
CertainTeed
SAINT-GOBAIN
Insul$afe°SP Fiber Glass Blowing Insulation
Manhattan Land Company
Homeowner Name / Jobsite Name
3824 Manhattan Ave Unit C-4
Home Address EcoFoam Insulation
5300 Broadway
Installer/Contractor(sign) Denver, CO 80216 Date
(303) 838-8455
Builder (sign) Company Name Date
Inspected By (sign if required) Date
OPEN ATTIC APPLICATION
R-VALUE
N0, BAGS PER 1.000
SO. Fr. NET AREA
MAXIMUM NET
COVERAGE
MINIMUM
WEIGHT
INITIAL INSTALLED
THICKNESS'
MINIMUM SETTLED
THICKNESS
To obtain thermal
resistance (R) of:
Number of bags
Contents of bag should
not cover more than: (sq. 8.)
Weight per sq. H. of installed
insulation should not be
less than: (Ibs,/sq. II.)
Installed insulation should not
be less than: (inches)
Installed insulation should not
be less than: (inches)
60
28.9 -.
34.5
0.897
21.75
21.75
49
23.5
42,6
0.727
18.25
18.25
44
20.8
48.0
0.646
.16.50
16.50
38
17.9
55.7
0.556
14.50
14.50
30
13.8
72.5
0A27
11-.50 -
11.50
26
11.8
84.8
0.366
10.00
10.00
-22 -
9.9
- 1014
0.306
- 8.50
8.50
19
6.6
116.2
0.267
7.50
7.50
13
5.9
- - 170.4
- 0.182 - -
--5.25
5.25
11
5.0
- 200.5
0.155
4.50
4.50
R•VAIUE
^TTHICKNESS �L
NELAREA�(S0 FT) ,L
IN9ULSAFE SP.(✓)
,:NUMBER OF BAGS USED II
BATTS/ROLLS (✓)
THERMAL PERFORMANCE -ATTIC BLOWING APPLICATION
• In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. of net area for each
R-value listed.
• The maximum net coverage must not exceed that specified for each R-value.
• The insulation must be installed at or above the specified installed thickness for each R-value.
• Failure to install the required minimum weight per sq. ft, of insulation at or above the initial installed thickness will result
in reduced R-value.
• This product should not be mixed with other blown insulations or the thermal claims will become invalid.
DANGER: RECESSED LIGHT FIXTURES -TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH
DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH
THERMALLY PROTECTED BALLASTS.