HomeMy WebLinkAbout3824 Manhattan Ave - Disclosures/Insulation - 01/27/2017 (2)Builders Statement CertaminTeed
SAINT-GOBAIN
InsulSafe"SP Fiber Glass Blowing Insulation
Manhattan Land Company
Homeowner Name / Jobsite Name
3824 Manhattan Ave Unit C-3
Home Address EcoFoam Insulation
Installer / Contractor (sign)
Builder (sign)
Inspected By (sign if required)
OPEN ATTIC APPLICATION
5300 Broadway
Denver, CO 80216
(303) 838-8455
Company Name
Date
Date
Date
R-VALUE
NO. BAGS PER 1,000
SO. FT. NET AREA
MAXIMUM NET
.COVERAGE
MINIMUM
WEIGHT
INITIAL INSTALLED
THICKNESS'
MINIMUM SETTLED
THICKNESS
re obtain (R)ofl
resistance (R) of:
Number of begs
Contents of bag should
not cover more than: (sq. 0.)
Weight per sq. It. of installed
insulation should not be
less than: (16s,/sg. It.)
Installed insulation should not
be less than: (inches)
Installed insulation should not
be less than: (inches)
60
289 -
34.5
0.897
' 21.75
21.75
49
23.5
- 42.6
0.727
18.25
18,25
_ 44
20.8
48.0
.. 0 646
_ 16.50
. 16.50
38
17.9
55.7
0.556
14,50
14.50
30
_
13.8
_
72.5
0.427
_
11.50
11.50
26
11.8
84.8
0.366
10.00
10.00
-22
9.9
101.4-
_ 0.306 -
8.50
8.50
19
8.6
116.2
0.267
7.50
7.50
13
5.9
--- 170.4
""-0.182" '-
5.25
- 5,25
11
5.0
200.5
0.155
4.50
4.50
11VALVE r __'THICKNESS 7
NET. f A i Fr) iN9UL5AFE SP (✓I NUMBER DF BAGS USED BATTSIROLLS (✓) �
�_ :_.. 1 __ . 1 _ It _.:
THERMAL PERFORMANCE -ATTIC BLOWING APPLICATION
• In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. of net area for each
R-value listed.
• The maximum net coverage must not exceed that specified for each R-value.
• The insulation must be installed at or above the specified installed thickness for each R-value.
• Failure to install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result
in reduced R-value.
• This product should not be mixed with other blown insulations or the thermal claims will become invalid.
DANGER: RECESSED LIGHT FIXTURES -TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH
DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH