HomeMy WebLinkAbout1063 Bella Vira Dr - Disclosures/Blower Door Test - 12/28/201613w,'t4 _1� -"; ILl0 SVgN
BUILDING LEAKAGE TEST
} ����.,ay��i� ('�Qc GS Services Ltd
IJ e Vyi c 2000 S. College Ave #308
ate• — Fort Collins, CO 80525
Email: BuildingPerformance@GSServices.com Website: GSServices.com a
2'.GEC 16 9a12l:iP1
Date of Test: 12/28/2016
Customer: Armstead Construction
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
Test File: Armstead - 1063 Bella Vira - BDma
Technician:
Project Number:
Building Address: 1063 Bella Vira Dr
Fort Collins, CO
1298 CFM50 (+/- 4.0 %)
2.46 ACH50
71.4 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 42.5 (+/- 27.6 %)
Exponent (n) = 0.874 ( +/- 0.077 )
Correlation Coefficient = 0.99614
4. Test Settings: Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
5. Accuracy Level Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate:
2. Estimated Design Infiltration Rate:
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
_b
GS-Seances
BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 12/28/2016 Test File: Armstead - 1063 Bella Vira - BDma
Building Information
Volume
31630
Surface Area
Floor Area
3016
Height
# of Bedrooms
# of Occupants
Year of Construction
Wind Shield
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
Location Climate Information
Ventilation Weather Factor
0.87
Energy Climate Factor
17.00
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
7.3 mph
Design Summer Wind Speed
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
_
15 deg F
Equipment Information
Type
Manufacturer
Model
Serial Number
Custom Calibration Date
Fan
Energy Conservatory
Model 3 (110V)
Default
Micromanometer
Energy Conservatory
DG700
No Text
No Text
No Text
No Text
No Text
No Text